ASTM C191-2008 Standard Test Methods for Time of Setting of Hydraulic Cement by Vicat Needle《用维卡针测定水硬性水泥凝固时间的标准试验方法》.pdf
《ASTM C191-2008 Standard Test Methods for Time of Setting of Hydraulic Cement by Vicat Needle《用维卡针测定水硬性水泥凝固时间的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C191-2008 Standard Test Methods for Time of Setting of Hydraulic Cement by Vicat Needle《用维卡针测定水硬性水泥凝固时间的标准试验方法》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 191 08American Association StateHighway and Transportation Officials StandardAASHTO No.: T131Standard Test Methods forTime of Setting of Hydraulic Cement by Vicat Needle1This standard is issued under the fixed designation C 191; the number immediately following the designation indicat
2、es the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 These test methods determine the time of set
3、ting ofhydraulic cement by means of the Vicat needle. Two testmethods are given; Method A is the Reference Test Methodusing the manually operated standard Vicat apparatus, whileMethod B permits the use of an automatic Vicat machine thathas, in accordance with the qualification requirements of thisme
4、thod, demonstrated acceptable performance.1.2 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of t
5、he user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. See 1.4 for aspecific warning statement.1.4 WarningFresh hydraulic cementitious mixtures arecaustic and may cause chemical burns to skin and tissue
6、uponprolonged exposure. The use of gloves, protective clothing,and eye protection is recommended. Wash contact area withcopious amounts of water after contact. Wash eyes for aminimum of 15 min. Avoid exposure of the body to clothingsaturated with the liquid phase of the unhardened material.Remove co
7、ntaminated clothing immediately after exposure.21.5 The text of this standard references notes and footnoteswhich provide explanatory material. These notes and footnotes(excluding those in tables and figures) shall not be consideredas requirements of the standard.NOTE 1For the method for determining
8、 the time of setting byGillmore needles, see Test Method C 266.2. Referenced Documents2.1 ASTM Standards:3C 150 Specification for Portland CementC 151 Test Method for Autoclave Expansion of HydraulicCementC 183 Practice for Sampling and the Amount of Testing ofHydraulic CementC 187 Test Method for N
9、ormal Consistency of HydraulicCementC 219 Terminology Relating to Hydraulic CementC 266 Test Method for Time of Setting of Hydraulic-Cement Paste by Gillmore NeedlesC 305 Practice for Mechanical Mixing of Hydraulic CementPastes and Mortars of Plastic ConsistencyC511 Specification for Mixing Rooms, M
10、oist Cabinets,Moist Rooms, and Water Storage Tanks Used in theTesting of Hydraulic Cements and ConcretesC 595 Specification for Blended Hydraulic CementsC 1005 Specification for Reference Masses and Devices forDetermining Mass and Volume for Use in the PhysicalTesting of Hydraulic CementsC 1157 Perf
11、ormance Specification for Hydraulic CementD 1193 Specification for Reagent Water3. Terminology3.1 DefinitionsThe terms used in this test method aredefined in accordance with Terminology C 219.4. Summary of Test Method4.1 A paste that is proportioned and mixed to normalconsistency, as described in th
12、e Test Method C 187, is moldedand placed in a moist cabinet and allowed to start setting.Periodic penetration tests are performed on this paste byallowing a 1-mm Vicat needle to settle into this paste. TheVicat initial time of setting is the time elapsed between theinitial contact of cement and wate
13、r and the time when thepenetration is measured or calculated to be 25 mm. The Vicatfinal time of setting is the time elapsed between initial contactof cement and water and the time when the needle does notleave a complete circular impression in the paste surface.5. Significance and Use5.1 This test
14、method provides a means of determiningcompliance with a specification limit for Vicat time of setting.Refer to the appropriate specification for the cement todetermine if this test method is used for specification compli-ance.1These test methods are under the jurisdiction of ASTM Committee C01 onCem
15、ent and is the direct responsibility of Subcommittee C01.30 on Time of Set.Current edition approved June 1, 2008. Published July 2008. Originally approvedin 1944. Last previous edition approved in 2007 as C 191 07.2Section on Safety, Manual of Cement Testing, Annual Book of ASTMStandards, Vol 04.01.
16、3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1*A Summary of Changes section appears at the end of this sta
17、ndard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.2 Time of setting measured by this method will notnecessarily provide the same results as the time of setting ofhydraulic cement paste measured by other methods, or the timeof se
18、tting of mortar or concrete.6. Apparatus6.1 Vicat ApparatusSee Annex A1.1 and Fig. A1.1. TheVicat apparatus for this test method shall have a movable rod,B, of mass 300 6 0.5g.6.1.1 The end of the rod used for measuring penetrationshall have a straight steel removable needle with a diameter of1.00 6
19、 0.05 mm and length no less than 50 mm.6.1.2 The needle end that contacts the specimen shall be flat,plane, and at right angles to the axis of the rod.6.2 Reference Masses and Devices for Determining Mass,conforming to the requirements of Specification C 1005. Thedevices for determining mass shall b
20、e evaluated for precisionand accuracy at a total load of 1000 g.6.3 Glass Graduates, 200 or 250-mLcapacity, and conform-ing to the requirements of Specification C 1005.6.4 Plane non-adsorptive plate, 100 6 5 mm square ofsimilar planeness, corrosivity, and absorptivity to that of glass(see Annex A1.1
21、, Fig. A1.1, H).6.5 Flat trowel, having a sharpened straight-edged steelblade 100 to 150 mm in length. The edges when placed on aplane surface shall not depart from straightness by more than 1mm.6.6 Conical ring, made of a rigid, non-corroding, non-absorbent material and having a height of 40 6 1 mm
22、, aninside diameter at the bottom of 70 6 3 mm, and an insidediameter at the top of 60 6 3 mm (see Annex A1.1, Fig. A1.1,G).6.7 Mixer, bowl, and paddle, conforming to Practice C 305.6.8 Automatic Vicat Needle Apparatus for Method BTheapparatus shall be equipped with a Vicat needle as described in6.1
23、.1 and 6.1.2. The total mass supported by the needle tip atthe time of measurement shall be 300 6 0.5 g. The instrumentshall be capable of automatically completing and recordingpenetration measurements of a test specimen at predeterminedtime intervals not exceeding 10 min and make each penetrationte
24、st at least 5 mm away from any previous penetration and atleast 10 mm away from the inner side of the mold.6.9 Specimen Mold for Method BThe cement paste is heldin a conical ring with the height of 40 6 1 mm and a removablebase plate. The test surface shall have a minimum diameter of60 6 3 mm.6.10 I
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC1912008STANDARDTESTMETHODSFORTIMEOFSETTINGOFHYDRAULICCEMENTBYVICATNEEDLE 用维卡针 测定 硬性 水泥 凝固时间 标准 试验

链接地址:http://www.mydoc123.com/p-465963.html