《ASTM C266-2008e1 Standard Test Method for Time of Setting of Hydraulic-Cement Paste by Gillmore Needles《用吉尔穆针法作水硬性水泥凝固时间的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C266-2008e1 Standard Test Method for Time of Setting of Hydraulic-Cement Paste by Gillmore Needles《用吉尔穆针法作水硬性水泥凝固时间的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C266 081Standard Test Method forTime of Setting of Hydraulic-Cement Paste by GillmoreNeedles1This standard is issued under the fixed designation C266; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last re
2、vision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEFig. 1 was corrected editorially in July 2011.1. Scope*1.1 This test method covers the determination of the time ofsetting of hydrau
3、lic-cement paste by means of the Gillmoreneedles.1.2 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.3 This standard does not purport t
4、o address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.Warning: Fresh hydraulic cementitious mixtures are
5、causticand may cause chemical burns to skin and tissue uponprolonged exposure. The use of gloves, protective clothing,and eye protection is recommended. Wash contact area withcopious amounts of water after contact. Wash eyes for aminimum of 15 min. Avoid exposure of the body to clothingsaturated wit
6、h the liquid phase of the unhardened material.Remove contaminated clothing immediately after exposure.1.4 The text of this standard references notes and footnoteswhich provide explanatory material. These notes and footnotes(excluding those in tables and figures) shall not be consideredas requirement
7、s of the standard.2. Referenced Documents2.1 ASTM Standards:2C151 Test Method for Autoclave Expansion of HydraulicCementC183 Practice for Sampling and the Amount of Testing ofHydraulic CementC187 Test Method for Amount of Water Required forNormal Consistency of Hydraulic Cement PasteC219 Terminology
8、 Relating to Hydraulic CementC305 Practice for Mechanical Mixing of Hydraulic CementPastes and Mortars of Plastic ConsistencyC511 Specification for Mixing Rooms, Moist Cabinets,Moist Rooms, and Water Storage Tanks Used in theTesting of Hydraulic Cements and ConcretesC670 Practice for Preparing Preci
9、sion and Bias Statementsfor Test Methods for Construction MaterialsC1005 Specification for Reference Masses and Devices forDetermining Mass and Volume for Use in the PhysicalTesting of Hydraulic CementsD1193 Specification for Reagent Water3. Terminology3.1 Refer to Terminology C219 for definitions o
10、f terms.4. Summary of Test Method4.1 Sufficient water is added to the cement that is beingtested to produce a paste of normal consistency. A specimen ismolded from this paste and is tested for time of setting bymeans of the Gillmore initial and final needles. The initial timeof setting is the time e
11、lapsed between initial contact of cementand water and the time when the Gillmore Initial needle doesnot leave a complete circular impression in the paste surface.The final time of setting is the time elapsed between initialcontact of cement and water and the time when the GillmoreFinal needle does n
12、ot leave a complete circular impression inthe paste surface.5. Significance and Use5.1 The purpose of this test method is to establish whethera cement complies with a specification limit on Gillmore timeof setting.6. Apparatus6.1 Flat Trowel, having a sharpened straight-edged steelblade 100 to 150 m
13、m in length. The edges when placed on aplane surface shall not depart from straightness by more than 1mm.1This test method is under the jurisdiction of ASTM Committee C01 on Cementand is the direct responsibility of Subcommittee C01.30 on Time of SetCurrent edition approved June 1, 2008. Published J
14、uly 2008. Originally approvedin 1951. Last previous edition approved in 2007 as C266 07. DOI: 10.1520/C0266-08.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the s
15、tandards Document Summary page onthe ASTM website.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.FIG. 1 Gillmore Apparatus and Test SpecimenC266 08126.2 Mixer, Bowl,
16、Paddle, and Scraper, conforming to therequirements of Practice C305.6.3 Glass Graduates, 200 or 250 mL capacity, conformingto the requirements of Specification C1005.6.4 Mass Determining Devices, conforming to the require-ments of Specification C1005. The devices for determiningmass shall be evaluat
17、ed for precision and accuracy at a totalload of 1000 g.6.5 Plane Non-absorptive Plates, 100 mm 6 5 mm square,of similar planeness, corrosivity, and absorptivity to that ofglass (see Test Method C187 Fig. 1, item H).6.6 Gillmore Needles, conforming to the following require-ments:6.6.1 The initial tim
18、e of setting needle shall have a mass of0.250 6 0.001 lb (113.4 6 0.5 g) and a tip diameter of 0.0846 0.002 in. (2.12 6 0.05 mm).6.6.2 The final time of setting needle shall have a mass of1.000 6 0.001 lb (453.6 6 0.5 g) and a tip diameter of 0.0426 0.002 in. (1.06 6 0.05 mm).6.6.3 The needle tips s
19、hall be cylindrical for a distance of0.189 6 0.020 in. (4.8 6 0.5 mm). The needle ends shall beplane and at right angles to the axis of the rod and shall bemaintained in a clean condition (See Note 1).6.7 Inspect and document Section 6 apparatus for confor-mance to the requirements of this test meth
20、od at least every212 years.NOTE 1The Gillmore needles should preferably be mounted as shownin Fig. 1 (b).7. Reagents7.1 Mixing WaterPotable water is satisfactory for routinetests. For all referee and cooperative tests, reagent waterconforming to the requirements of Specification D1193 forType III or
21、 Type IV grade of reagent water shall be used.8. Sampling8.1 When the test is part of acceptance testing, sample thecement in accordance with Practice C183.9. Conditioning9.1 Maintain the temperature of the room, dry materials,paddle, bowl, and plane non-absorptive plates at 23.0 6 3.0 C.Maintain th
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC2662008E1STANDARDTESTMETHODFORTIMEOFSETTINGOFHYDRAULICCEMENTPASTEBYGILLMORENEEDLES 吉尔 针法 硬性 水泥 凝固时间

链接地址:http://www.mydoc123.com/p-466138.html