ASTM C1450 C1450M-2004 Standard Specification for Non-Asbestos Fiber-Cement Storm Drain Pipe《非石棉的纤维混凝土雨水排放管的标准规范》.pdf
《ASTM C1450 C1450M-2004 Standard Specification for Non-Asbestos Fiber-Cement Storm Drain Pipe《非石棉的纤维混凝土雨水排放管的标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1450 C1450M-2004 Standard Specification for Non-Asbestos Fiber-Cement Storm Drain Pipe《非石棉的纤维混凝土雨水排放管的标准规范》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 1450/C 1450M 04Standard Specification forNon-Asbestos Fiber-Cement Storm Drain Pipe1This standard is issued under the fixed designation C 1450/C 1450M; the number immediately following the designation indicates theyear of original adoption or, in the case of revision, the year of last
2、 revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers non-asbestos fiber-cement pipeintended for use in storm-water drainage of highways, airports,fa
3、rms, foundations, and other similar drainage systems.1.2 The values stated in either inch-pound units or SI unitsare to be regarded separately as standard. Within the text, theSI units are shown in brackets. The values stated in eachsystem are not exact equivalents; therefore each system shallbe use
4、d independently of the other. Combining values from thetwo systems may result in nonconformance with the specifi-cation.NOTE 1Experience has shown that the successful performance of thisproduct depends upon the proper selection of the pipe strength, the type ofbedding and backfill, care that the ins
5、tallation conforms to the construc-tion specifications, and provision for adequate inspection at the construc-tion site. This specification does not include requirements for bedding,backfill, the relationship between field load conditions and the strengthdesignation of the pipe, or durability. These
6、 requirements should beincluded in the project specification.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-
7、bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C 150 Specification for Portland CementC 497 Test Methods for Concrete Pipe, Manhole Sections,or TileC 500 Test Methods for Asbestos-Cement PipeC 595 Specification for Blended Hydraulic CementsC 1154 Terminology
8、 for Non-Asbestos Fiber-ReinforcedCement Products2.2 Federal Standard:Fed. Std. No. 123 Marking for Shipment and (Civil Agen-cies)32.3 Military Standards:MIL-STD-105 Sampling Procedures and Tables for Inspec-tion by Attributes4MIL-STD-129 Marking for Shipment and Storage4MIL-STD-414 Sampling Procedu
9、res and Tables for Inspec-tion by Variables for Percent Defective42.4 Other Standards:Uniform Freight Classification Rules4National Motor Freight Classification Rules52.5 ISO Standards:ISO 390 : 1993 Products in Fibre Reinforced CementSampling and Inspection6ISO 2859 1: 1999 Sampling Procedures for
10、Inspection byAttributes Part 1: Sampling Schemes Indexed by Accep-tance Quality Limit (AQL) for Lot-by-Lot Inspection6ISO 3951: 1989 Sampling Procedures and Charts for In-spection by Variables for Percent Nonconforming63. Terminology3.1 DefinitionsRefer to Terminology C 1154.3.1.1 coupling, nin fibe
11、r-cement conduit, sewer, underd-rain and storm drain pipecomponent made from a largerdiameter pipe of the same type or class, or of Type II and ahigher class, or produced otherwise to yield at least equalperformance, for joining fiber-cement pipe that when properlyinstalled, forms a silt tight joint
12、, allows alignment correctionsand slight changes in direction, and provides an assembledjoint equivalent in serviceability and strength to the pipesections. Alternatively, for storm drain couplings, sleeves madefrom other materials that, when properly installed developsufficient tightness to prevent
13、 the surrounding soil from enter-ing the drain, may be used as couplings.1This specification is under the jurisdiction of ASTM Committee C17 onFiber-Reinforced Cement Products and is the direct responsibility of C17.02 onNon-Asbestos Fiber Cement Products.Current edition approved June 1, 2004. Publi
14、shed June 2004. Originallyapproved in 1999. Last previous edition approved in 2003 as C 145003ae1.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Docu
15、ment Summary page onthe ASTM website.3Available from Standardization Documents Order Desk, Bldg. 4, Section D,700 Robbins Ave., Philadelphia, PA 19111-5904 Attn: NPODS.4Available from the Uniform Classification Commission, Room 1106, 222 S,Riverside Plaza, Chicago, IL 60606.5Available from National
16、Motor Freight Inc., 1616 “P” St. NW, Washington, DC20036.6Available from International Organization for Standardization (ISO), 1 rue deVaremb, Case postale 56, CH-1211, Geneva 20, Switzerland.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United
17、States.4. Classification4.1 The types of pipe shall be shown as Type I and Type IIcorresponding to the chemical requirements given in S3.NOTE 2There are no chemical requirements for Type I pipe. Type IIpipe is generally accepted as being unaffected by sulfates in groundwaterwhich cause matrix expans
18、ion and consequential pipe deterioration.4.2 Fiber-cement storm drain pipe furnished under thisspecification shall be designated as Class I, II, III, IV, and V.The corresponding strength requirements are prescribed inTable 1. The D load is the saturated crushing test loadexpressed in pounds-force pe
19、r linear foot per foot of diameter.The D1 load is the saturated crushing test load expressed inNewtons per linear metre per millimetre of diameter. The pipeshall be furnished in 4, 6, 8, 10, 12, 15, 18, 21, 24, 27, 30, 33,36, 42 and 48-in. 100, 150, 200, 250, 300, 375, 450, 525, 600,675, 750, 825, 9
20、00, 1050 and 1200-mm sizes.4.3 When requested by the owner, the manufacturer shallprovide the owner the relationship between the short-termcrush load required to achieve long-term design loads withsupporting estimates of service life using recognized calcula-tion methods.5. Composition and Manufactu
21、re5.1 CompositionFiber-cement drain pipes shall be com-posed of an intimate mixture of an inorganic hydraulic binder(see Specification C 150) or a calcium silicate binder (seeSpecification C 595) formed by the chemical reaction of asiliceous material and a calcareous material reinforced byorganic fi
22、bers, inorganic non-asbestos fibers, or both. Processaids, fillers, and pigments which are compatible with fiber-reinforced cement are not prohibited from being added.5.1.1 The manufacturer shall state the type of fiber used inthe pipe, and, where requested, provide the owner withdocumented evidence
23、 that the fibers employed are compatiblewith other materials of that manufacturer.5.2 ManufactureThe pipe wall shall be of laminar con-struction formed under pressure to be a homogeneous struc-ture, and cured either under natural or accelerated conditions,to meet the physical requirements of this sp
24、ecification.6. Dimensions, Mass, and Tolerances6.1 The nominal length for fiber-cement storm drain pipeshall be designated by the manufacturer. Unless otherwiseagreed by the Owner, furnish a maximum of 15 % of the totalfootage of any one size and type for any order, at themanufacturers option, in pi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC1450C1450M2004STANDARDSPECIFICATIONFORNONASBESTOSFIBERCEMENTSTORMDRAINPIPE 石棉 纤维 混凝土 雨水 排放 标准规范

链接地址:http://www.mydoc123.com/p-464709.html