ASTM B911 B911M-2005 Standard Specification for ACSR Twisted Pair Conductor (ACSR TP)《钢心铝绞线(ACSR)双绞导线(ACSR TP)标准规范》.pdf
《ASTM B911 B911M-2005 Standard Specification for ACSR Twisted Pair Conductor (ACSR TP)《钢心铝绞线(ACSR)双绞导线(ACSR TP)标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM B911 B911M-2005 Standard Specification for ACSR Twisted Pair Conductor (ACSR TP)《钢心铝绞线(ACSR)双绞导线(ACSR TP)标准规范》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: B 911/B 911M 05Standard Specification forACSR Twisted Pair Conductor (ACSR/TP)1This standard is issued under the fixed designation B 911/B 911M; the number immediately following the designation indicates the yearof original adoption or, in the case of revision, the year of last revision
2、. A number in parentheses indicates the year of last reapproval.A superscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers ACSR Twisted Pair Conductor(ACSR/TP) for use as overhead electric conductors (see Notes1 and 2).NOTE 1Th
3、e conductor is fabricated from two component ACSRconductors of the same size twisted helically around each other. Thisconductor is identified by the code name of the component ACSRconductor followed by /TP or the size and type of the component ACSRconductor followed by /TP.NOTE 2There are registered
4、 trademark symbols that are also used toidentify the twisted pair notation. Consult cable manufacturers foradditional details.1.2 The values stated in inch-pound or SI units are to beregarded separately as standard. Each system shall be usedindependently of the other. Combining values from the twosy
5、stems may result in nonconformance with the specification.For conductor sizes designated by AWG or kcmil, the require-ments in SI units have been numerically converted fromcorresponding values stated or derived in inch-pound units. Forconductor sizes designated by SI units only, the requirementsare
6、stated or derived in SI units.1.2.1 For density, resistivity, and temperature, the valuesstated in SI units are to be regarded as standard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to
7、 establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 The following documents of the issue in effect on thedate of material purchase form a part of this specification to theextent referenced herein:2.2 A
8、STM Standards:2B 232/B 232M Specification for Concentric-Lay StrandedAluminum Conductors, Coated Steel Reinforced (ACSR)3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 component conductorsthe two conductors twisted tofabricate the finished ACSR/TP.4. Ordering Information4.1 Or
9、ders for material under this specification shall includethe following information:4.1.1 Quantity of each size,4.1.1.1 Conductor Sizekcmil area of the fabricatedACSR/TP (2 3 kcmil area of one of the component conduc-tors),4.1.2 Conductor type and the number of wires of thecomponent conductors,4.1.3 T
10、he type of steel core wire and type of coating,4.1.4 Place of inspection,4.1.5 Package size and type,4.1.6 Special package markings, if required, and4.1.7 Heavy wood lagging, if required.5. Requirements for Component Conductors5.1 Before twisting, the component conductors shall con-form to the requi
11、rements of Specification B 232.6. Twist6.1 The component conductors shall be twisted about them-selves with a complete twist every 9 ft 6 1 ft. This twist lengthshall be measured between the twisting machine and thetake-up reel with normal take-up tension on the ACSR/TP.NOTE 3The twist length can be
12、 altered as the ACSR/TP is wound uponto the take-up reel. It may not have the same twist length as when theTP is removed from the reel.6.2 The direction of the twist shall be left hand.7. Construction Requirements7.1 Construction requirements are given in Table 1 forACSR/TP.1This specification is un
13、der the jurisdiction of ASTM Committee B01 onElectrical Conductors and is the direct responsibility of Subcommittee B01.07 onConductors of Light Metals.Current edition approved Oct.1, 2005. Published November 2005. Originallyapproved in 2000. Last previous edition approved in 2000 as B 911/B 911M 00
14、.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box
15、 C700, West Conshohocken, PA 19428-2959, United States.TABLE 1 Construction Requirements for TP Type Conductor Using Aluminum Conductor, Steel Reinforced (ACSR)Code WordAEquivalentSize AWG orkcmilComponent Composition Outer Dimensions in.Nominal MassBlb/1000ft Rated Strg. lbCResistanceDOhms/1000ftdc
16、 at 20CAWG orkcmil Aluminum Steel minor majorSwan / TP 1 4 6 3 0.0834 1 3 0.0834 0.250 3 0.500 115 3700 0.2016Swanate / TP 1 4 7 3 0.0772 1 3 0.1029 0.257 3 0.514 115 4720 0.1994Swallow / TP 1/0 3 6 3 0.0937 1 3 0.0937 0.281 3 0.562 145 4600 0.1601Sparrow / TP 2/0 2 6 3 0.1052 1 3 0.1052 0.316 3 0.6
17、32 182 5660 0.1267Sparate / TP 2/0 2 7 3 0.0974 1 3 0.1299 0.325 3 0.650 213 7260 0.1253Robin / TP 3/0 1 6 3 0.1181 1 3 0.1181 0.354 3 0.708 230 7120 0.1005Raven / TP 4/0 1/0 6 3 0.1327 1 3 0.1327 0.398 3 0.796 290 8760 0.0796Quail / TP 266.2 2/0 6 3 0.1489 1 3 0.1489 0.447 3 0.894 336 10600 0.0633P
18、igeon / TP 335.6 3/0 6 3 0.1672 1 3 0.1672 0.502 3 1.004 461 13200 0.0502Penguin / TP 423.2 4/0 6 3 0.1878 1 3 0.1878 0.563 3 1.126 582 16700 0.0398Jaeger / TP 456.4 228.2 18 3 0.1126 1 3 0.1126 0.563 3 1.126 495 12100 0.0376Waxwing / TP 533.6 266.8 18 3 0.1217 1 3 0.1217 0.609 3 1.218 579 13700 0.0
19、322Spoonbill / TP 533.6 266.8 22 3 0.1101 7 3 0.0612 0.624 3 1.248 642 17400 0.0321Scaup / TP 533.6 266.8 24 3 0.1054 7 3 0.0703 0.633 3 1.266 687 20000 0.0320Partridge / TP 533.6 266.8 26 3 0.1013 7 3 0.0788 0.642 3 1.284 734 22600 0.0319Junco / TP 533.6 266.8 30 3 0.0943 7 3 0.0943 0.660 3 1.320 8
20、35 27800 0.0316Ostrich / TP 600.0 300.0 26 3 0.1074 7 3 0.0835 0.680 3 1.360 825 25400 0.0283Merlin / TP 672.8 336.4 18 3 0.1367 1 3 0.1367 0.683 3 1.366 730 17400 0.0255Trogon / TP 672.8 336.4 20 3 0.1297 7 3 0.0576 0.692 3 1.384 757 19000 0.0256Woodcock / TP 672.8 336.4 22 3 0.1237 7 3 0.0687 0.70
21、1 3 1.402 809 21800 0.0255Widgeon / TP 672.8 336.4 24 3 0.1184 7 3 0.0789 0.710 3 1.420 866 25000 0.0254Linnet / TP 672.8 336.4 26 3 0.1137 7 3 0.0884 0.720 3 1.440 925 28200 0.0253Oriole / TP 672.8 336.4 30 3 0.1059 7 3 0.1059 0.741 3 1.482 1053 34600 0.0251Chickadee / TP 795.0 397.5 18 3 0.1486 1
22、3 0.1486 0.743 3 1.486 862 19900 0.0216Ptarmigan / TP 795.0 397.5 20 3 0.1410 7 3 0.0627 0.752 3 1.504 895 22200 0.0216Stork / TP 795.0 397.5 22 3 0.1344 7 3 0.0747 0.762 3 1.524 956 25800 0.0216Brant / TP 795.0 397.5 24 3 0.1287 7 3 0.0858 0.772 3 1.544 1023 29200 0.0215Ibis / TP 795.0 397.5 26 3 0
23、.1236 7 3 0.0961 0.783 3 1.566 1093 32600 0.0214Lark / TP 795.0 397.5 30 3 0.1151 7 3 0.1151 0.806 3 1.612 1244 40600 0.0212Pelican / TP 954.0 477.0 18 3 0.1628 1 3 0.1628 0.814 3 1.628 1035 23600 0.0180Tailorbird / TP 954.0 477.0 20 3 0.1544 7 3 0.0686 0.823 3 1.646 1074 26200 0.0180Toucan / TP 954
24、.0 477.0 22 3 0.1472 7 3 0.0818 0.834 3 1.668 1148 30400 0.0180Flicker / TP 954.0 477.0 24 3 0.1410 7 3 0.0940 0.846 3 1.692 1227 34400 0.0179Hawk / TP 954.0 477.0 26 3 0.1354 7 3 0.1053 0.858 3 1.716 1312 39000 0.0178Hen / TP 954.0 477.0 30 3 0.1261 7 3 0.1261 0.883 3 1.766 1493 47600 0.0177Heron /
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMB911B911M2005STANDARDSPECIFICATIONFORACSRTWISTEDPAIRCONDUCTORACSRTP 钢心铝绞线 ACSR 导线 ACSRTP 标准规范 PDF

链接地址:http://www.mydoc123.com/p-462748.html