ASTM B910 B910M-2007 Standard Specification for Annealed Copper-Clad Steel Wire《退火铜包覆钢丝电线标准规范》.pdf
《ASTM B910 B910M-2007 Standard Specification for Annealed Copper-Clad Steel Wire《退火铜包覆钢丝电线标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM B910 B910M-2007 Standard Specification for Annealed Copper-Clad Steel Wire《退火铜包覆钢丝电线标准规范》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: B 910/B 910M 07Standard Specification forAnnealed Copper-Clad Steel Wire1This standard is issued under the fixed designation B 910/B 910M; the number immediately following the designation indicates the yearof original adoption or, in the case of revision, the year of last revision. A nu
2、mber in parentheses indicates the year of last reapproval.A superscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers bare round copper-clad steelfor the following applications: electrical, electronic, grounding,telecommunicatio
3、ns, and other applications.1.2 Four conductivities are covered as follows: 21, 30, 40,and 70 %.1.3 Temper is designated as annealed.1.4 The values stated in inch-pound or SI units are to beregarded separately as the standard. Each system shall be usedindependently of the other. Combining values from
4、 the twosystems may result in nonconformance with the specification.For conductor sizes designated byAWG, the requirements in SIunits have been numerically converted from correspondingvalues stated or derived in inch-pound units. For conductorsizes designated by SI units only, the requirements are s
5、tated orderived in SI units.1.5 The following precautionary statement pertains to thetest method portion only, Section 7, of this specification: Thisstandard does not purport to address all of the safety concerns,if any associated with its use. It is the responsibility of the userof this standard to
6、 establish appropriate safety and healthpractices and determine the applicability of regulatory limita-tions prior to use.2. Referenced Documents2.1 The following documents of the issue in effect on thedate of material purchase form a part of this specification to theextent referenced herein:2.2 AST
7、M Standards:2B 193 Test Method for Resistivity of Electrical ConductorMaterialsB 258 Specification for Nominal Diameters and Cross-Sectional Areas of AWG Sizes of Solid Round Wires Usedas Electrical Conductors2.3 NIST Document:3NBS Handbook 100 - Copper Wire Tables3. Ordering Information3.1 Orders f
8、or material under this specification shall includethe following information:3.1.1 Quantity of each size;3.1.2 Wire size: diameter in inches (see 5.2);3.1.3 Conductivity (see Table 1);3.1.4 Wire to be used for redraw or not;3.1.5 Packaging and shipping (see 10); and3.1.6 Place of inspection (see 6.1)
9、.4. Material4.1 The wire shall consist of a core of homogeneousopen-hearth, electric-furnace, or basic-oxygen steel with acontinuous outer cladding of copper thoroughly bonded to thecore throughout and shall be of such quality as to meet therequirements of this specification.5. General Requirements5
10、.1 Tensile Strength and ElongationThe copper-clad steelwire shall conform to the tensile strength requirements of Table2. Because there are many carbon steel and copper thicknesscombinations available, the desired tensile strength should beagreed upon between the purchaser and manufacturer prior top
11、lacing an order. The elongation shall be 15.0 % minimum forall diameters listed in 5.2.5.2 DimensionsThe wire size range for this specificationshall be from 0.0253 (0.643 mm) to 0.2294 in. (5.827 mm)diameter (see Note 1).5.2.1 Permissible VariationsThe wire sizes shall meet thefollowing tolerances:5
12、.2.1.1 For diameters 0.1000 in. (2.54 mm) and over, thewire shall not vary from the specified diameter by more than 6112 %, expressed to the nearest 0.0001 in. (0.003 mm).5.2.1.2 For diameters under 0.1000 in. (2.54 mm) and above0.0253 in. (0.643 mm), the wire shall not vary from thespecified diamet
13、er by more than 61 %, expressed to thenearest 0.0001 in. (0.003 mm).1This specification is under the jurisdiction of ASTM Committee B01 onElectrical Conductors and is the direct responsibility of Subcommittee B01.06 onComposite Conductors.Current edition approved Oct. 1, 2007. Published October 2007
14、. Originallyapproved in 2000. Last previous edition approved in 2006 as B 910/B 910M 06.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summa
15、ry page onthe ASTM website.3Available from National Institute of Standards and Technology (NIST), 100Bureau Dr., Stop 1070, Gaithersburg, MD 20899-1070, http:/www.nist.gov.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.NOTE 1The val
16、ues of the wire diameters in 5.2 are given to thenearest 0.0001 in. (0.003 mm) and correspond to the standard sizes givenin Specification B 258. The use of gage numbers to specify wire sizes isnot recognized in this specification because of the possibility of confusion.An excellent discussion of wir
17、e gages and related subjects is contained inNBS Handbook 100.5.3 Adhesion and Surface DefectsThe copper-clad steelwire, when tested in accordance with 7.4, shall not reveal anyseams, pits, slivers, or other imperfection of sufficient magni-tude to indicate inherent defects or imperfections. Examinat
18、ionof the wire at the break with the unaided eye (normal spectaclesexcepted) shall show no separation of copper from the steel.5.4 JointsNecessary joints in the wire and rods prior tofinal drawing shall be made in accordance with good commer-cial practice. The finished wire shall contain no joints o
19、r splicesmade at finished size.5.5 FinishThe wire shall be free from copper discontinui-ties and all imperfections not consistent with good commercialpractice (see 7.5).5.6 Copper ThicknessThe minimum copper thickness dueto eccentricity shall not be less than shown in Table 2.5.7 ResistivityThe elec
20、trical resistivity at a temperature of20C shall not exceed the values prescribed in Table 1. SeeNote 2 for calculating electrical resistance.NOTE 2Relationships which may be useful in connection with thevalues of electrical resistivity prescribed in this specification are shown inTable 2. Resistivit
21、y units are based on the International Annealed CopperStandard (IACS) adopted by IEC in 1913, which is158 ohm mm2/m at20C for 100 % conductivity. The value of 0.017241 ohm mm2/m and thevalue of 0.15328 ohm g/m2at 20C are, respectively, the internationalequivalent of volume and weight resistivity of
22、annealed copper equal to100 % conductivity. The latter term means that a copper wire 1 in. inlength and weighing 1 g would have a resistance of 0.15328 ohm. This isequivalent to a resistivity value of 875.20 ohm lb/mile2, which signifiesthe resistance of a copper wire 1 mile in length weighing 1 lb.
23、 It is alsoequivalent, for example, to 1.7241 ohm/cm of length of a copper bar 1 cm2in cross section. A complete discussion of this subject is contained inNBS Handbook 100. The use of five significant figures in expressingresistivity does not imply the need for greater accuracy of measurementthan th
24、at specified in Test Method B 193. The use of five significantfigures is required for complete reversible conversion from one set ofresistivity units to another.6. Inspection6.1 GeneralAll tests and inspections shall be made at theplace of manufacture unless otherwise agreed upon betweenthe manufact
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMB910B910M2007STANDARDSPECIFICATIONFORANNEALEDCOPPERCLADSTEELWIRE 退火 铜包覆 钢丝 电线 标准规范 PDF

链接地址:http://www.mydoc123.com/p-462745.html