1、Designation: B457 67 (Reapproved 2013)Standard Test Method forMeasurement of Impedance of Anodic Coatings onAluminum1This standard is issued under the fixed designation B457; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year
2、 of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method describes the conditions and equipmentfor measuring the impedance of anodic coatings on aluminum.
3、Such measurements have been used to evaluate the quality ofseal of an anodic coating. The test method does not prescribethe procedure for producing the anodic coating, nor thepostanodizing treatment usually described as “sealing.”1.2 This test method is applicable to the rapid, nondestruc-tive testi
4、ng of anodic coatings. The interpretation of results andcorrelation of data with service experience and other tests arenot within the scope of this test method.1.3 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.4 This standa
5、rd does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Nature of Test2.1 Impedance
6、 is an electrical characteristic described as thetotal opposition of all circuit elements to the flow of alternatingcurrent. Inductive effects of anodic coatings are negligible andthe impedance is presumed to be made up of resistance andcapacitive reactance according to the following relationships:Z
7、 5 =R21Xc2(1)andXc5 1/2 fC (2)where:Z = impedance,R = resistance,Xc= capacitive reactance,f = frequency, andC = capacitance.2.2 Both resistance and capacitance are associated with amaterial constant and a geometric factor:R 2 r l/A! (3)where:R = resistance,r = specific resistance,l = length of condu
8、ctor, andA = area of cross section of conductor.C 5 eA/l! (4)where:C = capacitance,e = dielectric constant,A = area of opposing plates of capacitor, andl = distance between plates.2.3 For measuring impedance of anodic coatings, the mate-rial constants are partly associated with the anodic coating an
9、dpartly with the electrolyte employed in the test cell. Forsimplification these constants are assumed not to vary. Thevariations in measured impedance then depend directly ongeometric factors.23. Apparatus3.1 Impedance BridgesCommercially available a-c im-pedance bridges with the following character
10、istics are satisfac-tory:33.1.1 Range1 F (1000 nF) to 0.0001 F (0.1 nF) fullscale with a dissipation factor of 0 to 2.1This test method is under the jurisdiction ofASTM Committee B08 on Metallicand Inorganic Coatings and is the direct responsibility of Subcommittee B08.07 onConversion Coatings.Curre
11、nt edition approved May 1, 2013. Published May 2013. Originallyapproved in 1967. Last previous edition approved in 2008 as B457 67 (2008)1.DOI: 10.1520/B0457-67R13.2The Alcoa Impedance Test for Anodic Coatings (AZTAC) evaluates a 0.129-cm2(0.02-in.2) test area and expresses impedance in kilohms. Ins
12、tructions areavailable fromAlcoa Process Development Laboratories, P.O. Box 2970, Pittsburgh,PA 15230.3The Z-Scope, formerly manufactured by Twin City Testing Corp., Tonawanda,NY was designed to measure the impedance of anodic coatings on aluminum.AZTAC values (the impedance of a 0.129-cm2(0.02-in.2
13、) test area) can be readdirectly in kilohms with this instrument.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States13.1.2 Frequency1000 Hz.3.1.3 Accuracy1%.3.1.4 VoltageAdjustable so as to be not greater than 0.5 Vas applied to the test
14、specimen.3.2 Cell (Fig. 1) for containing the electrolyte during test. Itmay be constructed from the following components:43.2.1 Glass Tube, 9 mm (0.35 in.) in outside diameter by 9cm (3.54 in.).3.2.2 Rubber Gasket or Seal.53.2.3 Rubber StopperAny convenient size with a hole incenter to accommodate
15、the glass tube.3.2.4 Platinum or Type 300 Stainless Steel CounterElectrode, 9 cm (3.54 in.) long by 0.75 to 1.0 mm (0.030 to0.040 in.) diameter wire.3.3 Wire Leads, two, insulated, approximately 1 m (40 in.)long complete with C-clamps or alligator clips shall be used formaking connections to the tes
16、t specimen and cell electrode.3.4 Support Strand, complete with a utility clamp to holdthe electrolytic test cell.3.5 Glass or Stainless Steel Tank containing pure boilingwater is required for conditioning the test specimen.3.6 Container for Cell StandardizationA 150 to 500-mLType 300 stainless stee
17、l beaker or standard 1-in.2test cell6maybe used.4. Electrolyte4.1 The electrolyte shall be a 312 % solution of sodiumchloride prepared by dissolving 36 g of the salt in 1 L ofdistilled or deionized water.5. Test Specimen5.1 The area to be tested should be sufficiently large toaccommodate the test ce
18、ll, sufficiently flat to prevent leakageof the solution from the probe, and free from mechanicaldefects such as scratches. After an anodic coating has beensealed, moisture is lost from the coating thus producing anincrease in impedance. The rate at which moisture is lostincreases as the relative hum
19、idity decreases; therefore, therelative humidity of the testing environment should be con-trolled and never below 25 %. Specimens should be testedwithin 1 h after the anodic coating has been sealed. If thiscannot be done or if the part has been subjected to an elevatedtemperature drying treatment, t
20、he test area should be condi-tioned as follows:5.1.1 Wipe the test area with acetone, methylethylketone,trichloroethylene, or similar solvent.5.1.2 Immerse the test area in pure boiling water for 30 s.5.1.3 Rinse in cold water.5.1.4 Blot dry and test without further delay.6. Procedure6.1 Penetrate t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMB45719672013STANDARDTESTMETHODFORMEASUREMENTOFIMPEDANCEOFANODICCOATINGSONALUMINUM 表面 阳极 镀层 阻抗 测定

链接地址:http://www.mydoc123.com/p-461284.html