1、STP-PT-064EVALUATION OF FRACTURE PROPERTIES TEST METHODS FOR HYDROGEN SERVICESTP-PT-064 EVALUATION OF FRACTURE PROPERTIES TEST METHODS FOR HYDROGEN SERVICE Prepared by: M. T. Miglin, PhD. Stress Engineering Services, Inc. Date of Issuance: June 24, 2013 This report was prepared as an account of work
2、 sponsored by ASME Pressure Technology Codes other forms of hydrogen damage are not included. The feasibility of a safety factor approach for the adjustment of the da/dN data from experiments to correspond to actual design parameters could not be specified because of the lack of full-scale test data
3、. Recommendations for an appropriate KTH value that represents expected vessel behavior are made. 2.1 Measurement of KTH Current testing procedures (paragraph KD-1045 ASME BPVC VIII, Div. 3) allow the determination of KTH by either constant displacement or constant load testing of fatigue precracked
4、 specimens. A review of these procedures and of the rising load test procedure is presented below. The available literature has been searched for the following information: (a) Static constant load or displacement vs. rising load test data (b) Effect of exposure time on static tests (c) Effect of st
5、rain or loading rate on rising load test (d) Effect of specimen size on both test methods (e) Application of static and rising load test data to actual pressure components in the presence of a crack. A critical evaluation has been made of the existing test procedures specified in ASTM and ISO standa
6、rds for measurement of KTH in hydrogen. The existing KTH test data for pressure vessel and piping steels in hydrogen has been compiled and compared. The literature was searched for full-scale test data to compare with properties obtained using the above-defined test procedures. No full-scale test da
7、ta were found. 2.2 Measurement of da/dN The available literature has been searched for information on the effects of test frequency, shape of the load-time cycle, and R-ratio on threshold fatigue crack growth rate, as follows: (a) The appropriate test frequency and R-ratio to be used in da/dN measur
8、ements are suggested. The test frequency and the R-ratio should adequately reflect the actual loading conditions expected in vessels during service, but are also be realistic for laboratory test conditions. No data was found for shape of the load-time cycle. (b) The effect of R-ratio on da/dN has be
9、en evaluated. Evaluation of Fracture Properties Test Methods for Hydrogen Service STP-PT-064 3 (c) A value of KTH for Q however, the presence of hydrogen increases the crack growth rate. Hydrogen reduces the KTH, and raising the R-ratio decreases KTH further. Figure 11 - Crack Growth Rate as a Funct
10、ion of K Showing Effects of Hydrogen and R-Ratio on the Shape of the Fatigue Crack Growth Rate Curve Note: IG = intergranular, T = transgranular, KTmax = threshold value, below which hydrogen has no effect on crack growth rates until the lower threshold region is reached 12. Evaluation of Fracture P
11、roperties Test Methods for Hydrogen Service STP-PT-064 13 The effect of hydrogen on the Ni-Cr-Mo steels HY80 and HY130 is shown in Figure 12. Hydrogen accelerates the fatigue crack growth rates for both steels over the air levels. Hydrogen has a greater effect on the lower strength steel. Figure 12
12、- Fatigue Crack Growth Rate of HY-80 and HY-130 in Air and Hydrogen 11 Figure 13 - Fatigue Crack Growth Rate of HY100 Steel in Hydrogen and Helium 11 Above the threshold region, the effects of hydrogen on fatigue crack growth are not simply due to the absence of oxygen. Hydrogen also increases fatig
13、ue crack growth rates relative to inert environments, K levels above threshold. Figure 13 shows higher fatigue crack growth rates (at K levels of 20 MPam and above) for HY100 in hydrogen than in helium. STP-PT-064 Evaluation of Fracture Properties Test Methods for Hydrogen Service 14 STB-X-2005Style
14、 Guide4.1 Effects of Frequency Cyclic frequency affects fatigue crack growth rates in hydrogen, but the magnitude of the effect depends upon the R-ratio and the steel. Figure 14 shows fatigue crack growth rates for DOT 4130X cylinder steel in hydrogen at two frequencies and R-ratios. Increasing the
15、frequency from 0.1 to 1.0 Hz affects the crack growth rates at R=0.5 but not at R=0.1 13. Figure 14 - Fatigue Crack Growth Rates for 4130X in Hydrogen at Two Frequencies and R-Ratios As shown in Figure 15, the effects of frequency on fatigue crack growth rate are prominent at high K values. Decreasi
16、ng frequency from 25 Hz to 0.01 Hz increases the fatigue crack growth rate by more than an order of magnitude. Figure 15 - Fatigue Crack Growth Rates for A3750 in Hydrogen at Frequencies Ranging from 0.01 to 25 Hz 14 Evaluation of Fracture Properties Test Methods for Hydrogen Service STP-PT-064 15 T
17、he effects of low frequencies are shown in Figure 16 for SA-105 C-Mn steel in 100 MPa H2. Crack growth rate is observed to increase with decreasing frequency from 1 Hz down to 0.00083 Hz, and the effect does not appear to saturate or reverse over that frequency range. Figure 16 - Fatigue Crack Growt
18、h Rate of SA105 C-Mn Steel in Hydrogen and Helium over a Range of Frequencies from 0.00083 to 1 Hz 10 In contrast, Figure 17 shows fatigue crack growth rates for X52 pipeline steel that remain stable as frequency is decreased from 0.1 Hz to 0.001 Hz for K=17.5 MPam. However, these tests were perform
19、ed at lower K levels than those in Figure 16. The frequency effect on crack growth rate is a function of the magnitude of da/dN. Figure 17 - Fatigue Crack Growth Rates as a Function of Frequency for X52 Pipeline Steel Tested at R=0.5 in Hydrogen Gas 13 STP-PT-064 Evaluation of Fracture Properties Te
20、st Methods for Hydrogen Service 16 STB-X-2005Style GuideIn Figure 18, fatigue crack growth data in hydrogen are plotted with respect to inverse frequency, such that the abscissa is in seconds. All testing was done at K=23 MPam 10. At this K level, in gaseous hydrogen, taking five seconds or more to
21、reach Kmax produces the fastest crack growth rates. This corresponds to a frequency of 0.1 Hz. Figure 18 - Effect of Frequency on Crack Growth Rates for C-Mn Steels Charged with Hydrogen in Aqueous Solution and in Gaseous Hydrogen The frequency selected for fatigue crack growth rate testing in hydro
22、gen must balance the conflicting issues of test duration and data reliability. The effect of frequency on crack growth rates diminishes at low da/dN levels, so near the threshold, higher frequencies can be used. From the data above, a frequency in the vicinity of 0.1 Hz appears to be a reasonable va
23、lue. 4.2 Effects of R-Ratio The applied load ratio R=Kmin/Kmax affects fatigue crack growth rates in the threshold region. Increasing the R-ratio increases the crack growth rates and thereby pushes the threshold to lower K levels. The data in Figure 19 illustrate this effect for 4340 low alloy steel
24、 in dry hydrogen. Figure 19 - Near-Threshold Fatigue Crack Growth Rate Curves for 4340 Steel in Dry Hydrogen at Various R-Ratios 15 Evaluation of Fracture Properties Test Methods for Hydrogen Service STP-PT-064 17 Figure 20 shows near threshold results in dry hydrogen plotted for several NiCrMoV ste
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASMESTPPT0642013EVALUATIONOFFRACTUREPROPERTIESTESTMETHODSFORHYDROGENSERVICE 作业 断裂 性能 试验 方法 评价 PDF

链接地址:http://www.mydoc123.com/p-456966.html