《ASHRAE IJHVAC 2-3-1996 International Journal of Heating Ventilating Air-Conditioning and Refrigerating Research《供暖 通风 空调和制冷研究的国际期刊 第2卷第3号 1996年7月》.pdf》由会员分享,可在线阅读,更多相关《ASHRAE IJHVAC 2-3-1996 International Journal of Heating Ventilating Air-Conditioning and Refrigerating Research《供暖 通风 空调和制冷研究的国际期刊 第2卷第3号 1996年7月》.pdf(95页珍藏版)》请在麦多课文档分享上搜索。
1、I n t ern at i on a 1 J o u rn al of H eat in g, Ven ti 1 a ti n g, 4 i r -C o n dit io II i n g a n d Ref ri get a t i n g Res e a tc II HVAC Vent. rate.* Velocity, YO Oh O? YO Location of Location of sampling point+ filter D:Under left hand F1 33 8 48 4 drawer of desk, 2 in. F2 70 18 78 10 (50 mm)
2、 from left F3 93 87 92 25 back comer F4 169 353 160 430 S: Midway between F1 80 13 83 13 shelves, 2 in. (50 F2 75 7 73 10 mm) from left comer F3 83 17 88 17 F4 72 11 73 21 L: In leg space F1 78 20 78 12 under desk, 2 in. F2 73 35 73 66 (50 mm) from top F3 99 75 101 69 - right back comer F4 87 114 -
3、G: Midway in gap F1 77 29 82 71 between desk and F2 79 61 78 67 wail, 12 in. (300 F3 105 141 103 1 O0 mm) above floor F4 93 43 94 68 G: As above, but F1 71 22 72 22 with horizontal F2 76 7 70 6 face of gap closed F3 95 156 97 137 F4 94 32 96 22 t See Figure 2. Relative to value at the room center wi
4、th the filter at F1: On high, q = 24.1 ach. u = 71.2 ft/min u36.2 cm/s). On low: a = 15.3 ach. u = 44.2 ft/min (22.5 cm/s). Again, the local ventilation rates did not vary as much as might be expected from the velocity, and were generally within about 3vo of the rate at the center of the room. The o
5、ne exception was under the left hand drawer (location D) with the filter at F1. where the ventilation rate was reduced by more than 50% with the filter on low and nearly 70% with the filter on high. The velocity at this location was no lower than at one or two other locations which showed only moder
6、ate reduction in ventilation rate. In cases where the filter was positioned such that the jet of filtered air impinged directly on the sampling location (for example location G with the filter at F3), the local ventilation rate was as high as or slightly exceeded that at the room center. The much hi
7、gher ventila- tion rates and velocities obtained at position D with the filter at position F4 are not sur- prising as the filter was within about 2 ft (610 mml of the measurement point. Closing the top face of the gap between the desk and the wail (location G) further indicated the lack of a correla
8、tion between velocity and ventilation rate. As shown in Table 2, closing the gap had a large effect on the velocity, yet the ventilation rates did not change much and were again within 30% of the room-center value. Of even more interest is that these findings suggest that effective ventilation of se
9、mi-enclosed regions can be achieved through a single opening. The dependence on the size of the opening and its orientation to the filter will now be examined in some detail. Ventiiation of an Enclosure To obtain further insight into the ventilation of partially enclosed regions, ventilation rates w
10、ere measured inside a box measuring 27 in. (686 mm) high, 23 in. (584 mm) wide and 28 in. (7 11 mm) deep with a volume of 10.1 ft3 (286 LI. Additional tests were done with the depth of the box reduced to 16.75 in. (426 mml and its volume to 6.0 ft3 ASHRAE TITLExIJHVAC 2-3 96 m 0759650 0523923 LTT m
11、182 HVAC - 0 30 30 20 20 10 10 O O c .- c ._ 3 O 1 2 3 40 1 2 3 4 O 1 2 3 40 1 2 3 4 Time, minutes Time, minutes Figure 8. Velocity measured at center of opening (circles) and near back of box (squares) MATHEMATICAL MODELING In modeling the ventilation of an enclosure with a single opening, the exch
12、ange with the surrounding air is generally considered to occur either as a result of turbulent eddies crossing the opening or by a pulsation type flow in and out of the enclosure (Cockroft and Robertson 1976. Holmes 1979, Haghighat et al. 1991, Narasaki et ai. 1991, van der Maas et al. 1991). Pulsat
13、ion dominates when the flow impinges directly on the opening (incident angle near O-), and eddy penetration dominates when the flow is parailel to the plane of the opening (incident angle near 90) (Haghighat et al. 1991). In our tests the dominant airflow near the box was parallel to the opening eve
14、n at an incident angle of O. This is because the jet from the filter stayed close to the floor until very close to the box and then turned up the face of the box. ASHRAE TITLE*IJHVAC 2-3 96 0757650 0523724 707 VOLUME 2, NUMBER 3. JULY 1996 185 Table 3. Velocities and Calculated Ventilation Rates for
15、 Box Diameter, d. Velocity through Calculated eddy Calculated ventilation inch (cm) opening, diffusivity Eq. IS), rate Eq. (4), ach ft/min (cm/s) R2/min (cm2/s) Small box, incident angle = O 10.0 (25.4) 32.5 (16.5) 9.0 (139) 58.9 7.5 (19. i) 33.1 (16.8) 6.9 (107) 33.7 6.0 (15.2) 33.1 (16.8) 5.5 (85)
16、 21.6 4.25 (10.8) 32.0 (16.3) 3.8 (59) 10.5 2.3 (5.9) 28.6 (14.5) 1.8 (28) 2.8 1.4 (3.6) 25.5 (13.0) 1.0 (16) 0.9 10.0 (25.4) 33.1 (16.8) 9.2 (142) 35.8 7.5 (19.1) 35.8 (18.2) 7.5 (1 16) 22.0 6.0 (15.2) 4.25 (10.8) 32.0 (16.3) 3.8 (59) 6.3 2.3 (5.9) 30.2 (15.3) 1.9 (30) 1.7 1.4 (3.6) 24.1 (12.2) 1.0
17、 (16) 0.5 Large box, incident angle = O Large box, incident angle = 45 10.0 (25.4) 31.9 (16.2) 8.9 (137) 34.6 7.5 (19. i) 31.0 (15.7) 6.5 (100) 18.9 6.0 (15.2) 4.25 (10.8) 28.3 (14.4) 3.4 (52) 5.5 2.3 (5.9) 21.7 (i 1.0) 1.4 (22) 1.3 1.4 (3.6) 21.9 (11.1) 0.8 (13) 0.5 Large box, incident angle = 90 1
18、0.0 (25.4) 17.3 (8.8) 4.8 (74) 18.8 7.5 (19.1) 16.4 (8.3) 3.4 (53) 10.0 6.0 (15.2) 15.4 (7.8) 2.5 (39) 6.0 4.25 (10.8) 13.7 (7.0) 1.6 (25) 2.7 2.3 (5.9) 10.7 (5.4) 0.7 (i i) 0.6 1.4 (3.6) 14.0 (7. i) 0.6 (9) 0.3 Large box, incident angle = 135 10.0 (25.4) 15.4 (7.8) 4.3 (66) 16.7 7.5 (19.1) 15.8 (8.
19、0) 3.3 (51) 9.6 6.0 (15.2) 12.2 (6.2) 2.0 (31) 4.8 4.25 (10.8) 11.9 (6.1) 1.4 (22) 2.3 2.3 (5.9) 9.9 (5.0) 0.7 (10) 0.6 1.4 (3.6) 7.4 (3.8) 0.3 (5) 0.2 Large box, incident angle = 180 10.0 (25.4) 15.8 (8.0) 4.4 (68) 17.1 7.5 (19.1) 16.4 (8.3) 3.4 (53) 10.0 6.0 (15.2) 16.1 (8.2) 2.7 (42) 6.3 4.25 (10
20、.8) 13.8 (7.0) 1.6 (25) 2.7 1.4 (3.6) 5.9 (3.0) 0.3 (4) o. 1 2.3 (5.9) 10.0 (5.1) 0.7 (10) 0.6 ASHRAE TITLE*IJHVAC 2-3 9b m 0359b50 0523925 845 m 186 HVACBrR RESEARCH Eddy Diffusion The air exchange is represented by an effective diffusion coefficient De If ce is the par- ticle concentration in an e
21、nclosure of volume V and c, the particle concentration in the room, then conservation of mass requires that for diffusion across an opening of area A where d is the characteristic length of the enclosure over which the concentration change takes place. Defining the ventilation rate of the enclosure
22、qe as Ade q =- e Vd Equation (3) becomes (4) subject to the initial condition ce = c, = ci at t = O. point to point and, using Equation (1). can be expressed as As discussed previously, the particle concentration in the room changes little from cr = ciexp(-q,t) (6) It follows from Equations (5) and
23、(6) that or To test Equation (8). some measure of the eddy diffusion coefficient De is required. It can be assumed that De = kd (9) where k is a constant, Y is the mean air velocity through the opening, and, following Holmes (1979). the characteristic length d can be taken to be the diameter of the
24、open- ing. The mean velocity measured at the center of the opening (see Table 3) was used to calculate the diffusion coefficient using Equation (9) with k = 0.33, and the ventilation rate for the enclosure could then be obtained from Equation (4). The calculated ventila- tion rates are included in T
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASHRAEIJHVAC231996INTERNATIONALJOURNALOFHEATINGVENTILATINGAIRCONDITIONINGANDREFRIGERATINGRESEARCH 供暖

链接地址:http://www.mydoc123.com/p-455194.html