1、ASHRAE Guideline 22-2012Supersedes ASHRAE Guideline 22-2008Instrumentationfor MonitoringCentral Chilled-WaterPlant EfficiencyApproved by the ASHRAE Standards Committee on July 20, 2012, and by the ASHRAE Board of Directors on July 26, 2012.ASHRAE Guidelines are scheduled to be updated on a five-year
2、 cycle; the date following the guideline number is the year ofASHRAE Board of Directors approval. The latest edition of an ASHRAE Guideline may be purchased on the ASHRAE Web site(www.ashrae.org) or from ASHRAE Customer Service, 1791 Tullie Circle, NE, Atlanta, GA 30329-2305. E-mail:ordersashrae.org
3、. Fax: 404-321-5478. Telephone: 404-636-8400 (worldwide) or toll free 1-800-527-4723 (for orders in US andCanada). For reprint permission, go to www.ashrae.org/permissions. 2012 ASHRAE ISSN 1049-894XDISCLAIMERASHRAE uses its best efforts to promulgate Standards and Guidelines for the benefit of the
4、public in light of available information andaccepted industry practices. However, ASHRAE does not guarantee, certify, or assure the safety or performance of any products, components,or systems tested, installed, or operated in accordance with ASHRAEs Standards or Guidelines or that any tests conduct
5、ed under itsStandards or Guidelines will be nonhazardous or free from risk.ASHRAE INDUSTRIAL ADVERTISING POLICY ON STANDARDSASHRAE Standards and Guidelines are established to assist industry and the public by offering a uniform method of testing for ratingpurposes, by suggesting safe practices in de
6、signing and installing equipment, by providing proper definitions of this equipment, and by providingother information that may serve to guide the industry. The creation of ASHRAE Standards and Guidelines is determined by the need for them,and conformance to them is completely voluntary.In referring
7、 to this Standard or Guideline and in marking of equipment and in advertising, no claim shall be made, either stated or implied,that the product has been approved by ASHRAE.ASHRAE Guideline Project Committee 22Cognizant TC: TC 9.1, Large Building Air-Conditioning SystemsSPLS Liaison: Robert G. Doerr
8、*Denotes members of voting status when the document was approved for publicationCharles G. Arnold, Chair* James B. Rishel*Thomas E. Cappellin* Michael M. Roberts*Kenneth L. Gillespie, Jr.* Michael. C. A. SchwedlerThomas B. Hartman Daryl K. Showalter*Mark C. Hegberg Ian D. Spanswick*Roy S. Hubbard, J
9、r. Laurance S.Staples, Jr.John L. Kuempel, Jr.* John I. Vucci*ASHRAE STANDARDS COMMITTEE 20112012Carol E. Marriott, Chair Krishnan Gowri Janice C. PetersonKenneth W. Cooper, Vice-Chair Maureen Grasso Douglas T. ReindlDouglass S. Abramson Cecily M. Grzywacz Boggarm S. SettyKarim Amrane Richard L. Hal
10、l James R. TaubyCharles S. Barnaby Rita M. Harrold James K. VallortHoy R. Bohanon, Jr. Adam W. Hinge William F. WalterSteven F. Bruning Debra H. Kennoy Michael W. WoodfordDavid R. Conover Jay A. Kohler Craig P. WraySteven J. Emmerich Eckhard A. Groll, BOD ExOAllan B. Fraser Ross D. Montgomery, COSte
11、phanie C. Reiniche, Manager of StandardsSPECIAL NOTEThis Guideline was developed under the auspices of ASHRAE. ASHRAE Guidelines are developed under a review process, identifyinga guideline for the design, testing, application, or evaluation of a specific product, concept, or practice. As a guidelin
12、e it is not definitive butencompasses areas where there may be a variety of approaches, none of which must be precisely correct. ASHRAE Guidelines are writtento assist professionals in the area of concern and expertise of ASHRAEs Technical Committees and Task Groups.ASHRAE Guidelines are prepared by
13、 project committees appointed specifically for the purpose of writing Guidelines. The projectcommittee chair and vice-chair must be members of ASHRAE; while other committee members may or may not be ASHRAE members, allmust be technically qualified in the subject area of the Guideline.Development of
14、ASHRAE Guidelines follows procedures similar to those for ASHRAE Standards except that (a) committee balance isdesired but not required, (b) an effort is made to achieve consensus but consensus is not required, (c) Guidelines are not appealable, and(d) Guidelines are not submitted to ANSI for approv
15、al.The Manager of Standards of ASHRAE should be contacted for:a. interpretation of the contents of this Guideline,b. participation in the next review of the Guideline,c. offering constructive criticism for improving the Guideline, ord. permission to reprint portions of the Guideline. ASHRAE (www.ash
16、rae.org). For personal use only. Additional reproduction, distribution, or transmission in either print or digital form is not permitted without ASHRAEs prior written permission.CONTENTSASHRAE Guideline 22-2012Instrumentation for Monitoring Central Chilled-Water Plant EfficiencySECTION PAGEForeword.
17、 21 Purpose 22 Scope . 23 Definitions. 24 Utilization 25 Chilled-Water Plant Types and Instrumentation . 36 Data Gathering and Trending . 77 Calculations 78 References . 8Informative Appendix AExample Instrument Specifications Table 9Informative Appendix BDetermination of kW/ton 11Informative Append
18、ix CUncertainty Impacts on Measurement Requirements 12Informative Appendix DData Gathering and Trending 15Informative Appendix EExample Specification Language. 16Informative Appendix FExample Application. 28Informative Appendix GExamples of Analyzed Data 35Informative Appendix HBibliography. 39NOTEA
19、pproved addenda, errata, or interpretations for this guideline can be downloaded free of charge from the ASHRAE Web site at www.ashrae.org/technology. 2012 ASHRAE1791 Tullie Circle NEAtlanta, GA 30329www.ashrae.orgAll rights reserved. ASHRAE (www.ashrae.org). For personal use only. Additional reprod
20、uction, distribution, or transmission in either print or digital form is not permitted without ASHRAEs prior written permission.2 ASHRAE Guideline 22-2012(This foreword is not part of this guideline. It is merelyinformative and does not contain requirements necessaryfor conformance to the guideline.
21、)FOREWORDGuideline 22 was developed by ASHRAE to provide asource of information on the instrumentation and collection ofdata needed for monitoring the efficiency of an electric-motor-driven central chilled-water plant. A minimum level of instru-mentation quality is established to ensure that the cal
22、culatedresults of chilled-water plant efficiency are reasonable. Sev-eral levels of instrumentation are developed so that the user ofthis guideline can select the level that suits the needs of eachinstallation.The basic purpose served by this guideline is to enablethe user to continuously monitor ch
23、illed-water plant efficiencyin order to aid in the operation and improvement of that par-ticular chilled-water plant, not to establish a level of efficiencyfor all chilled-water plants. Therefore, the effort here is toimprove individual plant efficiencies and not to establish anabsolute efficiency t
24、hat would serve as a minimum standardfor all chilled-water plants.It is recognized that there are different needs for monitor-ing the efficiency of a chilled-water plant. In most cases, theprincipal objective is to maintain and improve the efficiency ofthe chilled-water plant. There are also cases w
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASHRAEGUIDELINE222012INSTRUMENTATIONFORMONITORINGCENTRALCHILLEDWATERPLANTEFFICIENCYPDF

链接地址:http://www.mydoc123.com/p-454880.html