ASHRAE 4750-2005 Determination of Building Materials′ Transport Properties for Modeling VOC Emissions《测定建材?建模挥发性有机化合物排放的运动性》.pdf
《ASHRAE 4750-2005 Determination of Building Materials′ Transport Properties for Modeling VOC Emissions《测定建材?建模挥发性有机化合物排放的运动性》.pdf》由会员分享,可在线阅读,更多相关《ASHRAE 4750-2005 Determination of Building Materials′ Transport Properties for Modeling VOC Emissions《测定建材?建模挥发性有机化合物排放的运动性》.pdf(13页珍藏版)》请在麦多课文档分享上搜索。
1、4750 Determination of Building Materials Transport Pro pe rt es for Modeling VOC Emissions Miao Yang Student Member ASHRAE T.Q. Dang, PhD J.S. Zhang, PhD Member ASHRAE H. Li Student Member ASHRAE X.F. Gao ABSTRACT Material transport properties, such as difusion coefl- cients and partition coeficient
2、s, are necessary for modeling VOC emissions from building materials and their potential impact on indoor air quality. A modi3ed experimentalproce- dure for VOC emission testing was developed in this study to determine these properties. It consists of a static period (i.e., zero air exchange) followe
3、d by a dynamic period. The concen- trations measured at the end of the static period were used to represent the equilibrium concentration and, together with the data from the dynamic period, to determine the initial VOC content in the test specimen. An iterative numerical procedure with simulated an
4、nealing method was developedfor analyzing the experimental data to determine the partition and difusion coeflcients. The numerical procedure uses the measured data to estimate the initial value of the partition coejcient, and it was able togive a unique estimation of thepartiction anddifu- sion coef
5、icients from regresssion analysis of the measured data. Uncertainties of the experimental and numericalproce- dures were analyzed. Six building materials (vinyl siding, spunbonded olefn Tyvek TM, oriented strand board, jber batt insulation, gypsum wallboard, and interiorpaint) that are typically use
6、d in a wood-framed residential wall assembly were tested using a small stainless steel environmental cham- ber (50 L volume). VOCs emitted from each material were identified using thermal desorption GC/MS analyses of air samples collected in sorbent tubes. A thermal desorption-GC/ FID system was use
7、d to analyze the air samples to determine the VOC concentrations in the chamber as functions of time, and the VOC emission rates over time were also calculated. The numericalprocedure developed was used to determine the partition coefficient Zhang 1999). To use the model, one needs to know the parti
8、tion coefficient (K,) and diffusion coefficient (0,) of the materials for the VOC(s) of interest. A conventional chamber test method is characterized by a dynamic test only (Little et al. 1994). The proposed chamber test method is characterized by both static and dynamic tests. Equilibrium concentra
9、tion is obtained from the static test. The objectives of this study were to (I) develop an exper- imental procedure for determining K, and D, using small environmental chambers; (2) conduct uncertainty and sensi- tivity analyses to estimate the uncertainty of the method; and (3) determine the K, and
10、 Dm values for commonly used wall materials. Mia0 Yang and H. Li are graduate research assistants, J.S. Zhang is an associate professor, T.Q. Dang is a professor, and X.F. Gao is a former graduate research assistant in the Department of Mechanical, Aerospace and Manufacturing Engineering, Syracuse U
11、niversity, Syracuse, NY. aa 02005 ASHRAE. EXPERIMENTAL METHOD Test Facility A small environmental chamber test facility consisting of a clean air supply system, chamber assemblies, a humidity control system, a temperature control system, and a data acquisition system was used in this study (Figure 1
12、 from Zhang et al. 2002b). The small chambers, with dimensions of 0.5 m x 0.4 m x 0.25 m, were made of electro-polished 316 stainless steel. To create airtight sealing, Teflon gaskets (Gore-Tex joint sealant) were used to seal the covers of the chambers. Relative humid- ity for each chamber was meas
13、ured using an RH probe (HX94, accuracy +0.6“C), while temperatures at different locations inside the enclosure were monitored using thermocouples (accuracy +OSOC). The data acquisition system, a CR23x micrologger, was connected to thermocouples and humidity sensors to monitor the temperature and rel
14、ative humidity for each chamber. The SKC pocket-sampling pump and stainless steel sorbent tubes were used to collect samples in each test. The adsorbents used in this study were Carbopack C (60/80 mesh) and Carbopack B (60180 mesh) at a 2:l ratio (200 mg vs. 100 mg), while the GC was a Perkin-Elmer
15、Autosystem XL GC system with FID detection. The capillary column was a J RF, is the response factor of toluene (aredpg); Re, is the relative response factor, which is the ratio of the response factor of a selected chemical of interest against that of toluene. Therefore, M- - 1 e osampiing VOsampiing
16、Fict 2 2 2 = /(f7%) + (rtl%) + (f6%) + = I9.3%. Uncertainty in the impact of specimen variability Magee et al. (2003) conducted a series of small chamber tests of OSB to examine the degree of variability that can occur in the emissions of VOCs from a single building product. It was found that mill-m
17、ill differences were qual- itatively and quantitatively evident, as were differences between production dates, between individual panels with the same production date, and even between speci- mens taken from a single panel. Two samples of OSB from a single panel were tested and variation of equilib-
18、 rium concentration was about 10%. NUMERICAL MODEL AND DATA ANALYSES Governing Equations the following diffusion model (Zhang et al. 1999): The emissions from a dry material layer are described by For the material layer: For the material-air interface: For the air inside the chamber: Boundary condit
19、ions: S = -D rn .A!$ly=, at the material-air interfaceb = 1) (4) -D - - O at the bottom of the material layer (y = O) ay (5) where A = exposed surface area of the specimen, m2 Ca*(& CJt) = air phase concentration in the chamber air and at the air-material interface respectively. Assume that the conc
20、entration gradient in the boundary layer over the surface is negligible, pg /m3 ca(t)= c,*(t) = concentration in the supply air, pg /m3 = concentration in solid materials at a certain location 0.) and time (t), pg /m3 Cin Cm (y, t) ASHRAE Transactions: Research 91 Dm = diffusion coefficient, m21s Km
21、a = partition coefficient Q = supply airflow rate, m3/s S = emission rate as defined in Equation 4, pg 1s V = chamber volume, m3 Y = distance from bottom of the material layer, m Little et al. (1994) provided an analytical solution to this model that can predict emissions from individual materials,
22、but an analytical solution does not exist for multi-layer wall assemblies. In this study, we used a numerical approach to solve the equations so that the numerical simulation module can be readily used in predicting emissions from multi-layer wall assemblies with appropriate boundary conditions and
23、transport properties (i.e., K, and 0,) in the next phase of the study (see Li et al. 2003). Nondimensional Form of the Equations defined as The time scale for the diffusion inside the material may be 2 5 = 6 /D, where 6 is the thickness of the material, defined as the length scale. With this time an
24、d length scale, and choosing the initial concentration in the material as the reference concentration (Cmo), Equation 1 can be written in the following dimension- less form: where - Cm c, = - m i=-=- t t j=21 fi2/D, 6 Likewise, the VOC mass balance equation in the chamber can also be normalized. Thi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASHRAE47502005DETERMINATIONOFBUILDINGMATERIALS TRANSPORTPROPERTIESFORMODELINGVOCEMISSIONS 测定 建材 建模 挥发性

链接地址:http://www.mydoc123.com/p-454333.html