ASD-STAN PREN 2853-1998 Aerospace Series Current Ratings for Electrical Cables with Conductor EN 2083 (Edition P 1)《航空航天系列 使用EN 2083导线的电缆的电流额定值 第P1版》.pdf
《ASD-STAN PREN 2853-1998 Aerospace Series Current Ratings for Electrical Cables with Conductor EN 2083 (Edition P 1)《航空航天系列 使用EN 2083导线的电缆的电流额定值 第P1版》.pdf》由会员分享,可在线阅读,更多相关《ASD-STAN PREN 2853-1998 Aerospace Series Current Ratings for Electrical Cables with Conductor EN 2083 (Edition P 1)《航空航天系列 使用EN 2083导线的电缆的电流额定值 第P1版》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、STD.AECflA PREN 2853-ENGL 1998 lnl1231l 00111308 2b Edition approved for publication AECMA STANDARD NORME AECMA AECMA NORM C2 Chairman Comments should be sent within six months after the date of publication to prEN 2853 EdWnPl Janury lSS8 PUBLISHED BY THE EUROPEAN ASSOCIATION OF AEROSPACE INDUSTRIES
2、 (AECMA) Gulledelle 94 - B-1200 BRUXELLES - Tel. (+32) 2 775 81 10 - Fax. (+32) 2 775 81 11 ICs: 49.060 Descriptors: Aerospace industry, aircraft equipment, electric cables, current ratings, conductors ENGLISH VERSION Aerospace series Current ratings for electrical cables with conductor EN 2083 Srie
3、 arospatiale Intensits admissibles dans les cbles lectriques conducteur EN 2083 Luft- und Raumfahrt Strombelastbarkeit von elektrischen Leitungen mit Leiter nach EN 2083 This “Aerospace Series“ Prestandard has been drawn up under the responsibility of AECMA (The European Association of Aerospace Ind
4、ustries). It is published on green paper for the needs of AECMA-Members. It has been technically approved by the experts of the concerned Technical Committee following comment by the Member countries. Subsequent to the publication of this Prestandard, the technical content shall not be changed to an
5、 extent that interchangeability is affected, physically or functionally, without re-identification of the standard. After examination and signature of the AECMA Standard Checking Centre (NPSI and formal agreement of the Official Services of the Member countries it will be submitted as a draft Europe
6、an Standard to CEN (European Committee for Standardization) for formal vote. 1998-01-30 AECMA Gulledelle 94 E1 200 BRUXELLES Mr Peuetta aecma 1998 STDmAECHA PREN 2053-ENGL 1998 1012311 00143I17 7b2 M Page 2 prEN 2853: 1998 Contents list 1 Scope 2 Normative references 3 Definitions 4 Rationale 5 Tabu
7、lated data Annex A (informative): Supplementary notes Annex B (normative): Current rating tests STD-AECMA PREN 2853-ENGL 1998 LO1231l 0014310 484 Page 3 prEN 2853: 1998 1 Scope 1.1 EN 2083. This standard specifies current rating data for cables produced with conductors as defined in 1.2 requirements
8、 of EN 3197, 5.4 and 6.1, are satisfied. Electrical ratings for continuous and short term conditions are tabulated such that the 1.3 A procedure for establishing cable current ratings is given in annex B of this specification. 1.4 The basis for determining current of cables has been to employ a 40 O
9、C rise as the electrical contribution to operating temperature. Note is made in this standard that, in practice, the voltage drop requirements of EN 2282 will often dictate lower current densities. Additionally, reference to appropriate aerospace series standards for cable terminations and connector
10、s will show constraints which may dictate cable size. 1.5 It is stressed that the current ratings given in this document relate solely to copper and copper alloy conductors as defined in EN 2083. The values are based upon historical evidence and are subject to the caveat given in 4.1. Accordingly th
11、e acceptance of data without verification in any particular case is a matter of discretion by both the aircraft design and certification authorities. 2 Normative references This European Standard incorporates by dated or undated reference provisions from other publications. These normative reference
12、s are cited at the appropriate places in the text and the publications are listed hereafter. For dated references, subsequent amendments to or revisions of any of these publications apply to this European Standard only when incorporated in it by amendment or revision. For undated references the late
13、st edition of the publication referred to applies. EN 2083 Copper and copper alloy conductors for electrical cables - Aerospace series 1) EN 2282 Aerospace Series - Characteristics of aircraft electrical supplies EN 3197 Aerospace Series - Installation of aircraft electrical and optical interconnect
14、ion systems 2) EN 3475-1 O0 Aerospace series - Cables, electrical, aircraft use - Test methods - Part 100: General 2) 3 Definitions For the purpose of this standard the definitions for electrical cables are to be found in EN 3475 and EN 31 97, with the following additions: 3.1 Tu: lhe unpowered cond
15、uctor temperature of a cable when in an operating environment. 3.2 any combination of electrical heating and ambient condition shall not be prejudicial to design life. Tr: The maximum rated temperature of a cable. Operation at or below this temperature by 3.3 stated without causing the specified val
16、ue of Tr to be exceeded. Duty cycle rating: The load current which may be passed through a cable for the duration 1 ) Published as AECMA Standard at the date of publication of this standard 2) Published as AECMA Prestandard at the date of publication of this standard 4 Rationale 2s 4.1 It is recogni
17、zed that the determination of precise current ratings for every cable construction and size can be shown to be a complex matter. Factors such as the thermal conductivity and thickness of insulation, test methods and the criteria employed will all have some effect. The intent of this standard is that
18、 the data presented should be sufficiently accurate to permit good engineering judgement to be exercised in the context of EN 3197. However, to enable verification of precise cable rating as noted in clause 1, a preferred method of measurement is given in annex B of this standard. 10 s I I min 4.2 C
19、able current ratings are provided primarily, to facilitate selection of the appropriate size to carry a given load. These ratings are also employed to assist, but not solely to determine, the setting of electrical protection levels. Historically some agencies have specified ?short term current ratin
20、gs? in cable specifications and such data represented current values and durations which were deemed to be just below the overload damage point. Implicitly these were fault conditions and were to be experienced on only rare occasions. In this standard this approach has been changed and the short ter
21、m ratings given herein are those which may be employed within a duty cycle, without prejudice to installed life. As noted in clause 1, cable rating has been determined as that current which will cause conductor temperature to rise by 40 OC and therefore this same value has been employed for short te
22、rm ratings. 4.3 Annex A of this specification provides supplementary notes to the foregoing clauses. 5 Tabulated data 5.1 Current ratings Table 1 : Current ratings for aircraft cable with copper conductors Copper alloy conductors * Take care of compatibility between load current of cables and that e
23、mployed for terminations and circuit breakers. NOTE 1: The Duty cycle ratings and the continuous ratings are current values which may be employed without detriment to normal life. They have been determined from cables rates at a Tr of 135 OC which have been heated by electrical loading from a Tu of
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASDSTANPREN28531998AEROSPACESERIESCURRENTRATINGSFORELECTRICALCABLESWITHCONDUCTOREN2083EDITIONP1 航空航天

链接地址:http://www.mydoc123.com/p-451551.html