ARMY MIL-F-20420 J (4)-1993 FLARE SURFACE TRIP M49A1 PARTS AND LOADING ASSEMBLING AND PACKING《M49A1零件高强度及高延性外表照明弹的装载 组装和包装》.pdf
《ARMY MIL-F-20420 J (4)-1993 FLARE SURFACE TRIP M49A1 PARTS AND LOADING ASSEMBLING AND PACKING《M49A1零件高强度及高延性外表照明弹的装载 组装和包装》.pdf》由会员分享,可在线阅读,更多相关《ARMY MIL-F-20420 J (4)-1993 FLARE SURFACE TRIP M49A1 PARTS AND LOADING ASSEMBLING AND PACKING《M49A1零件高强度及高延性外表照明弹的装载 组装和包装》.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、e MIL-F-20420J (4) 9999906 1845278 224 D I INCH-POUND I MIL-F-2042OJ(AR) AMENDMENT 4 12 March 1993 SUPERSEDING AMENDMENT 3 20 May 1991 MILITARY SPECIFICATION FLARE, SURFACE, TRIP M49A1, PARTS, AND LOADING, ASSEMBLING AND PACKING This amendment forms a part of MIL-F-20420J(AR), dated 25 March 1983, a
2、nd is approved for use by the U.S. Army Armament, Munitions and Chemical Command and is available for use by all Departments and Agencies of the Department of Defense, PAGE 1 2.1.1 Delete: “FEDERAL QQ-P-416 - Plating, Cadmium (Electro deposited)“. PAGE 3 2.2 Add new paragraph as follows: “2.2 Non-Go
3、vernment publications, The following document(s) form a part of this document to the extent specified herein. unless otherwise specified, the issues of the documents which are DOD adopted are those listed in the issue of the DODISS cited in the solicitation. Unless otherwise specified, the issues of
4、 documents not listed in the DODISS are the issues of the documents cited in the solicitation. AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM) ASTM - B117 “STANDARD METHOD OF SALT SPRAY (FOG) TESTING“ (Application for copies should be addressed to the American Society for Testing and Materiais, 19
5、16 Race Street, Philadelphia, PA 19103.)“ 3.5.2 Cold temperature: Add the phrase, “except that the pull pin force requirements do not apply.“ to the last sentence. 3.5.3 Delete: “Temperature and Humidity Cycling“ and substitute “Temperature and Humidity Cycling (First Article Only) “. AMSC N/A 1 of
6、12 FSC DISTRIBUTION S TATEMFNT A. Approved for public release; distribution is unlimited. 137 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-F-20420J (4) 9999906 II845279 IIbO MIL-F-2042OJ(AR) AMENDMENT 4 PAGE 5 Table I: Change the number of sam
7、ple units on each of the items on the first page of Table I from “25“ to “10“. PAGE 6 Table I: Change the number of sample units on each item on the second page of Table I from “25“ to “10“. PAGE 7 Table I: Paragraph Reference for the Flare Assembly Examination of Defects: Change from 4.4.2.19“ to 4
8、.4.2.19, 4.4.2.20, 4.4.2.21 and 4.4.2.22 (except 105 thru 109)“. - “4.4.2.18, a jor defect Change the number of sample units for the examination of defects for the Trigger Spring, Retainer Spool, and the Wire Spool Assembly from “25“ to “10“. PAGE 9 4.4.2.1 Delete major defect 102 and Substitute: “1
9、02 Thickness of bottom excluding angular surface, min. 0.40% 3.2 Gage“. Delete major defect 105 and minor defect 202 in their entirety. PAGE 10 4.4.2.2 Delete major defect 109 and substitute: “109 Angle Add major defect 110: “110 Protective coating test 4.4.3.7, of turn-up at end of handle, min, 0.4
10、0% 3.2 Gage“. 4.4.3.7, 3.2, 4.4.3.7“. Delete minor defects 204, 205, and 206 in their entirety. PAGE 11 4.4.2.2 Add minor defects: “214 Presence of dimple (2 places) 0.65% 3.2 Visual“. “215 Height of turn-up at end of handle, min. 0.653 3.2 Gage“. Delete minor defects 208, 209, 210, and 211 in their
11、 entirety. 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-F-20420J (4) Ob LB45280 982 MIL-F-2042OJ(AR) AMENDMENT 4 PAGE 12 4.4.2.3 Delete major defect 103 and substitute: “103 Location of firing pin hole 0.40% 3.2 Gage“. Delete minor defect 20
12、3 in its entirety. PAGE 13 4.4.2.4 Delete major defect 101 and Substitute: “101 Location of pont 0.40% 3.2 Gage“. Delete major defect 103 and substitute: “103 Point profile damaged 0.40% 3.2 Gage“. Add major defeck 105: “105 Protective coating test 4.4.3.7 4.4.3.7 3.2 4.4.3.7“. PAGE 15 4.4.2.6 Delet
13、e minor defect 201 and substitute: “201 Length from top edge of bracket to top edge of slot 0.65% 3.2 Gage“. Delete minor defect 203 and substitute: “203 True position of carriage bolt holes (round and square) 0.65% 3.2 Gage“. Delete minor defect 204 and substitute: “204 True position of trigger piv
14、ot hole 0.65% 3.2 Gage“. Add Note 1 callout to minor defect 205. Delete minor defect 207 and substitute: “207 Width of mounting surface, min 0.65% 3.2 Gage“. Add the following under notes: “1 Surface imperfections which cause the local material thickness to be below minimum shall be classed defectiv
15、e, Cracks appearing on the top lugs or the tabs of the “E“ slot will not be permitted.“ 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-F-20420J (4) 9999906 L84528L 819 Ec MIL-F-2042OJ(AR) AMENDMENT 4 PAGE 16 4.4.2.7 Add major defect 106: “106
16、Protective coating test 4.4.3.7 4.4.3.7 3.2 4.4.3.7“. Add Note 1 callout to major defect 104. Add the following under notes: 1 Surface imperfections in the finger area which result in a local thickness or width that is less than the minimum required shall be class-d defective.“ PAGE 18 4.4.2.9 Add m
17、ajor defect 102: “102 Protective coating test 4.4.3.7 4.4.3.7 3.2 4.4.3.7“. PAGE 19 4.4.2.10 Delete major defect 101 and substitute: 101 Diameter of wire .(before forming) 0.40% 3.2 Gage“. PAGE 20, 21 and 23 Delete in their entirety and substitute new page 20, 21 and 23 included. PAGE 22 4.4.2.13 De
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILF20420J41993FLARESURFACETRIPM49A1PARTSANDLOADINGASSEMBLINGANDPACKINGM49A1 零件 强度 延性 外表 照明弹 装载 组装

链接地址:http://www.mydoc123.com/p-444588.html