ARMY MIL-DTL-62187 C-2009 REGULATOR 650 AMP SOLID STATE《650安培固态调节器》.pdf
《ARMY MIL-DTL-62187 C-2009 REGULATOR 650 AMP SOLID STATE《650安培固态调节器》.pdf》由会员分享,可在线阅读,更多相关《ARMY MIL-DTL-62187 C-2009 REGULATOR 650 AMP SOLID STATE《650安培固态调节器》.pdf(31页珍藏版)》请在麦多课文档分享上搜索。
1、Comments, suggestions, or questions on this document should be addressed to U.S. Army Tank-automotive and Armaments Command, ATTN: RDTA-EN/DM/STND, MS# 268, 6501 E. 11 Mile Road, Warren, MI 48397-5000 or emailed to DAMI_STANDARDIZATIONconus.army.mil. Since contact information can change, you may wan
2、t to verify the currency of this address information using the ASSIST Online database at http:/assist.daps.dla.mil. ASMC N/A FSC 2920 INCH-POUND MIL-DTL-62187C 29 September 2009 SUPERSEDING MIL-DTL-62187B 6 January 1999 DETAIL SPECIFICATION REGULATOR, 650 AMP, SOLID STATE This specification is appro
3、ved for use by all Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This specification covers a solid state voltage regulator for use in engine driven military ground vehicles. 2. APPLICABLE DOCUMENTS 2.1 General. The documents listed in this section are specified in sectio
4、ns 3 and 4 of this specification. This section does not include documents cited in other sections of this specification or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document users are cautioned that they must meet
5、 all specified requirement documents cited in sections 3 and 4 of this specification, whether or not they are listed. 2.2 Government documents. 2.2.1 Specifications, standards, and handbooks. The following specifications, standards, and handbooks form a part of this document to the extent specified
6、herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract (see 6.2). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-62187C 2 SPECIFICATIONS DEPARTMENT OF DEFENSE SPECIFICATIONS MIL-DTL-
7、62186 - Generator, Alternating Current (650 Ampere Rectified), 28 Volts Direct Current (Oil Cooled) STANDARDS DEPARTMENT OF DEFENSE STANDARDS MIL-STD-461 - Requirements for the Control of Electromagnetic Interference Characteristics of Subsystems and Equipment (See 4.2.1) MIL-STD-810 - Environmental
8、 Test Methods and Engineering Guidelines (See 4.2.1) (Unless otherwise indicated, copies of the above specifications, standards, and handbooks are available from the Document Automation and Production Service, Building 4/D, 700 Robbins Avenue, Philadelphia, PA 19111-5094 or website: http:/assist.dap
9、s.dla.mil/quicksearch/.) 2.2.2 Other Government documents, drawings, and publications. The following other Government documents, drawings, and publications form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the so
10、licitation or contract (see 6.2). DRAWINGS ARMY 11655469 - Generator AC/DC (Oil Cooled) 12354334 - Regulator, Solid State. (Copies of these drawings are available from the U.S. Army Tank-automotive and Armaments Command, RDTA-EN, 6501 E. 11 Mile Road, Warren, MI 48397-5000.) 2.3 Non-Government publi
11、cations. The following documents form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract (see 6.2). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from
12、 IHS-,-,-MIL-DTL-62187C 3 GENERAL MOTORS CORPORATION (GM) GM 9540P - Accelerated Corrosion Test. (Copies of GM publications may be obtained from General Motors Corporation, c/o Global Engineering, 15 Inverness Way, Englewood, CO 80112 or at website: http:/ 2.4 Order of precedence. Unless otherwise n
13、oted herein or in the contract, in the event of a conflict between the text of this document and the references cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. RE
14、QUIREMENTS 3.1 First article. When specified (see 6.2 and 6.3), a sample shall be subjected to first article inspection in accordance with 4.1.1. 3.2 Design, materials, and manufacturing processes. The design, materials, and manufacturing process shall conform to Drawing 12354334. 3.2.1 Recycled, re
15、covered, or environmentally preferable materials. Recycled, recovered, or environmentally preferable materials should be used to the maximum extent possible provided that the material meets or exceeds the operational and maintenance requirements, and promotes economically advantageous life cycle cos
16、ts (see 6.5.1). 3.3 Operating requirements. All regulators shall meet the performance requirements as specified in 3.3.1 through 3.3.11 when operating on a generator-alternator conforming to MIL-DTL-62186 (see 4.4.1). 3.3.1 Voltage regulation. The regulator shall establish and maintain output voltag
17、e in accordance with figures 1 and 2, throughout the generator-alternator speed range of 2400 to 8000 revolutions per minute (rpm) (see 4.4.1.1). 3.3.2 Ripple voltage. Ripple voltage shall not exceed 4 volts (V) peak-to-peak, with output voltage at 28 V direct current (dc), throughout the generator
18、speed range of 2400 to 8000 rpm (see 4.4.1.2). 3.3.3 Overvoltage. The regulator shall deactivate the field circuit when the system voltage (Es) reaches 33.0 1.0 V. Deactivation and return to battery voltage shall be accomplished in 0.07 seconds. Reset shall be manual and shall be located on the regu
19、lator (4.4.1.3). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-62187C 4 3.3.4 False trips. False tripping of the regulator shall not be caused by buildup, load switching, and input speed acceleration or deceleration (see 4.4.1). 3.3.5 Curre
20、nt limit. The regulator shall limit the generator-alternator output current in accordance with figure 3. Stable current limiting shall be established within 0.50 seconds. System voltage undershoot shall be not below 18 V (see 4.4.1.4). 3.3.6 Accessory control. The regulator shall incorporate circuit
21、ry to energize an accessory control device that closes when the generator-alternator speed is between 900 and 1100 rpm. During shutdown, this device shall open before the generator-alternator speed reaches 800 rpm. The circuitry, when energized, shall produce at least 0.25 amperes (A) at a voltage n
22、ot less than 18 V (see 4.4.1.5). 3.3.7 Fault protection. The regulator shall include circuitry that deactivates the field circuit in the event of wiring malfunctions. This circuitry shall operate only if a malfunction in any of the trip types of table I creates a condition which would damage the reg
23、ulator or associated electrical power sources. Maximum voltage and trip time limits shall be as specified in table I for the three trip types (see 4.4.1.6). TABLE I. Trip types. Trip type Generator-alternator rpm Alternator output voltage (EA) V System voltage (ES) V Time (seconds) Regulator sensing
24、 2400 35.0 35.0 1.00 Input lead 8000 35.0 35.0 0.4 Alternator positive 2400 40.0 35.0 1.00 Output lead 8000 115.0 35.0 0.4 Alternator negative 2400 40.0 35.0 1.00 Output lead 8000 115.0 35.0 0.4 3.3.8 Dielectric strength. The regulator circuit insulation to ground shall not permit a leakage current
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILDTL62187C2009REGULATOR650AMPSOLIDSTATE650 安培 固态 调节器 PDF

链接地址:http://www.mydoc123.com/p-444398.html