ARMY MIL-C-51540 A-1994 CONTROL MODULE (FOR THE M84 FILTER UNIT)《控制模块(M84滤波器装备)》.pdf
《ARMY MIL-C-51540 A-1994 CONTROL MODULE (FOR THE M84 FILTER UNIT)《控制模块(M84滤波器装备)》.pdf》由会员分享,可在线阅读,更多相关《ARMY MIL-C-51540 A-1994 CONTROL MODULE (FOR THE M84 FILTER UNIT)《控制模块(M84滤波器装备)》.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、I INCH-POUND I MIL-C-51540A(EA) 17 February 1994 SUPERSEDING 21 March 1989 MIL- C-5 1540(EA) MILITARY SPECIFICATION CONTROL MODULE (FOR THE M4 FILTER UNIT) This specification is approved for use by the U. S. Amy Edgewood Research, Development and Engineering Center; Department of the Army, and is av
2、ailable for use by all Departments andAgencies of the Department of Defense. 1. SCOPE 1.1 Scope. This specification covers an electrical control module functioning as a distribu- tion center for 28 volt (V) direct current (DC) and 208 V, 400 Hertz (Hz), 3-phase electrical circuits. 2. APPLICABLE DOC
3、UMENTS 2.1 Government documents, drawings, and publications. The following Government docu- ments, drawings, and publications form a part of this document to the extent specified herein. Unless otherwise specified, the issues are those cited in the solicitation. U.S. ARMY EDGEWOOD RESEARCH, DEVELOPM
4、ENT AND ENGINEERING CENTER DRAWINGS 5- 19-6906 - Control module Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be of use in improving this document should be addressed to: Technical Director, U.S. Army Edgewood Research, Development and Engineering Cente
5、r, Am: SCBRD-ENE-S, Aberdeen Proving Ground, MD 21010-5423 by using the self-addressed Standardization Document Improvement Proposal (DD Form 1426) appearing at the end of this document or by letter. AMSC NIA FSC 4240 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited.
6、Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-flIL-C-Sl1540A m 999990b 1992b4b O26 MIL- C -5 154OA(EA) SPECIAL PACKAGING INSTRUCTIONS (SPI) P5-19-6906 - Control module (Copies are available from Commander, U.S. Army Information Systems Command, Am:
7、 SMCRI-IMO-D, Rock Island, IL 61299-7210.) 2.2 Non-Government publications. The following documents form a part of this document to the extent specified herein. Unless otherwise specified, the issues of the documents which are DOD adopted are those listed in the issue of the DODISS cited in the soli
8、citation. Unless oth- erwise specified, the issues of documents not listed in the DODISS are the issue of the docu- ments cited in the solicitation (see 6.2). ASTM STANDARDS D 3951 - Commercial Packaging (Application for copies should be addressed to ASTM, 1916 Race Street, Philadelphia, PA 19103- 1
9、187.) (Non-Government standards and other publications are normally available from the or- ganizations that prepare or distribute the documents. These documents also may be available in or through libraries or other informational services.) 2.3 Order of precedence. In the event of a conflict between
10、 the text of this document and the references cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been ob- tained. 3. REQUIREMENTS 3.1 Materials and components. 3.1.1 Materiais. All ma
11、terials cited on Drawing 5- 19-6906 shall conform to the specifica- tions listed thereon and to the specific characteristics set forth on the drawings listed thereon. 3.1.2 Components. All components of the control module shall conform to the specifica- tions and drawings listed on Drawing 5-19-6906
12、. 3.2 Manufacture and assembly. The control module shall be manufactured and assembled in accordance with Drawing 5- 19-6906. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL- C - 5 1540A( EA) 3.3 Performance. The following circuits shall conform
13、to the schematic representations on Drawings 5-19-6907 and 5-19-6908, and shall perform as specified in 3.3.1 through 3.3.7 when the applicable air pressures, voltages, and circuit sequences are applied to specific junc- tions on the control module and tested in accordance with 4.4.6. 3.3.1 Intercon
14、necting circuits. There shall be continuity between the circuit points in table I and an open between the circuit points in table II when tested as specified in 4.4.6.2. TABLEI. Cont inuity betwee n points I Pin/connector or test point to Pidconnector I 57 - D 57 - H TP - 1 TP - 3 TP-4 54 - D, 57 -
15、A 54 - G, 55 - F, 55 - B, TP - 5,54 - F 55 - C, 54 - E 55 - D 55 - E TABLE II. Open crrcuit between Do ints I Pin/connector to Pidconnector I 57 - A 57 - B 57 - C 57 - D 54 - A 54 - B 57 - B, 57 - C, 57 - H, 54 - A J7 - C, 57 - D, 57 - H, 54 - B 57 - D, 57 - H, 54 - C, 57 - H 54 - B, 54 - C 54 - C 3
16、.3.2 System power circuit breaker. There shall be an open circuit between test point 2 and pin E of 54 with the system power circuit breaker open and continuiy with the breaker closed when tested as specified in 4.4.6.3. 3.33 PE system circuit breaker. There shall be an open circuit between pins A a
17、nd G of 55 and test point 2 with the protective entrance (PE) system circuit breaker open and continuity with the breaker closed when tested as specified in 4.4.6.4. 3.3.4 Power relay circuit. The power relay shall pull in and there shall be continuity between the circuit points in table III when te
18、sted as specified in 4.4.6.5. 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-C-5L540A = 0b 12b48 T MIL-C-51540A(EA) TABLE III. Cont inuity betwee n points (Dowe r relay circuit) I Pin/connector to Pidconnector I 57 - A 57 - B 57 - C 54 - A 54
19、- B 54 - C 3.3.5 Indicators. All indicators (see Drawings 5- 19-6907 and 5- 19-6908) on the module shall light when tested as specified in 4.4.6.6. 3.3.6 Warning system. When tested as specified in 4.4.6.7, the warning system shall function as follows: The MASK indicator shall flash and the horn sha
20、ll sound with a pulsating tone be- tween 0.5 and 1.1 inches water gauge (iwg). The peak horn level shall be at least 68 dB in at least one octave band between 200 and 5000 Hz. After 15 to 25 seconds, the horn shall silence and the MASK indicator shall stop flashing and remain ON. The MASK indicator
21、shall go out be- tween 0.5 and 1.1 iwg. 3.3.7 DC voltage. The dc voltage shall be 30 k 3 volts between test point 2( +) and test point 5(-) when tested as specified in 4.4.6.8. 3.3.8 hss of power. The MASK indicator shall flash and the horn shall sound with a pulsat- ing tone when the 208 Vac input
22、power is lost when test as specified in 4.4.6.9. 3.4 First article. When specified (see 6.2), a sample shall be subjected to the first article inspection in accordance with 4.3. 3.5 Workmanship. The control module shall be free from cracked, bent, or dented metal sections, sharp edges, and foreign m
23、atter (dirt, oil, or viscous materials). 4. QUALITY ASSURANCE PROVISIONS 4.1 Responsibility for inspection. Unless otherwise specified in the contract or purchase order, the contractor is responsible for the performance of all inspection requirements (exami- nations and tests) as specified herein. E
24、xcept as otherwise specified in the contract or purchase order, the contractor may use his own or any other facilities suitable for the performance of the inspection requirements specified herein, unless disapproved by the Government. The Govern- ment reserves the right to perform any of the inspect
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILC51540A1994CONTROLMODULEFORTHEM84FILTERUNIT 控制 模块 M84 滤波器 装备 PDF

链接地址:http://www.mydoc123.com/p-441827.html