ARMY MIL-B-44418-1991 BOOT WALL FABRIC ASSEMBLIES STANDARDIZED INTEGRATED COMMAND POST SYSTEM (SICPS)《标准化联合指挥系统(SICPS)纤维组件靴墙》.pdf
《ARMY MIL-B-44418-1991 BOOT WALL FABRIC ASSEMBLIES STANDARDIZED INTEGRATED COMMAND POST SYSTEM (SICPS)《标准化联合指挥系统(SICPS)纤维组件靴墙》.pdf》由会员分享,可在线阅读,更多相关《ARMY MIL-B-44418-1991 BOOT WALL FABRIC ASSEMBLIES STANDARDIZED INTEGRATED COMMAND POST SYSTEM (SICPS)《标准化联合指挥系统(SICPS)纤维组件靴墙》.pdf(20页珍藏版)》请在麦多课文档分享上搜索。
1、MIL-B-444 18 (a) 28 June 1991 MILITARY SPECIFICATION Bo(Tr wAL;L, FABRIC ASSEMELIES, STANDARDIZED ImEmATED CmMAND F)sr SYSTEM (SIBS) This specification is approved for use by the Natick Research, Developnent, and Engineering Center, Department of the Anrty, and is available for use by all Department
2、s and Agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This specification covers five types of bootwalls. 1.2 Classification. The boot wall shall be of the following types and classes as specified (see 6.2). Type1 - SIBS, M577 Tracked Cannand Post Boot Wall Type II - SIBS, Rigid Wall Shelt
3、er (W) Boot Wall Type III - SIBS, M1037, S250/G Boot Wall Type IV - SIBS, M1037, S250E Boot Wall Typev - SIBS, M998, M1038 Troop - Cargo Carrier Boot Wall Class 1 - Green Class 2 - Desert tan 2. APPLICABLE IxnmEms 2.1 Govenmient do. F -. *. - , 2. -_ .s I. *. 3 Provided by IHSNot for ResaleNo reprod
4、uction or networking permitted without license from IHS-,-,-3.2.1 Alternate conpsonents. Components offered as equivalent to components specified hereinafter and on the referenced drawings as a specific manufacturers part or model number or equal, shall be functionally equal to the manufacturers mod
5、el number identified, and of equal or better quality. The incorporation and inclusion of such a component in the design of the specified end product shall not require modification or change to any other specified component, and shall not reduce ease of maintenance to it or any other components, unle
6、ss such modification or change is specially approved by the contracting officer. if none is required, prior to comnencing production, the contractor shall suhnit for the contracting officers approval, a list identifying each component, together with proof that each listed component carplies with req
7、uirements specified above. require a sample of the proposed substitution. Approval of the subitteci listing, together with the necessary supporting data, authorizes carmiencement of manufacture but does not relieve the contractor of responsibility that these components perform in accordance with spe
8、cified requirements when incorporated into the end product. Prior to the manufacture of the first article, or The contracting officer, at his option, my 3.3 Desiqn and construction. 3.3.1 Boot Wall tm. 3.3.1.1 Type I. The design and construction for the type I boot wall shall conform to Drawing 5-4-
9、7484 and all subsidiary drawings and parts lists and as specified herein. 3.3.1.2 Type II. The design and construction for the type II boot wall shall conform to Drawing 5-4-8183 and all subsidiary drawings and parts lists and as specified herein. 3.3.1.3 Type III. The design and construction for th
10、e type III boot wall shall conform to Drawing 5-4-7409 and all subsidiary drawings and parts lists and as specified herein. 3.3.1.4 Type IV. The design and construction for the typ N boot wall shall conform to Drawing 5-4-8213 and all subsidiary drawings and parts lists and as specified herein. 3.3.
11、1.5 TVpe V. The design and construction for the type V boot wall shall conform to Drawing 5-4-8456 and all Subsidiary drawings and parts lists and as specified herein. 3.3.2 Fusinu of ends of synthetic cord, minu and tam. All ends of synthetic cord, webbing and tape shall be fused. the cord, webbing
12、, and tape ends shall be capable of providing sufficient heat to provide a smooth edge with the cut ends of the cord, webbing and tape yarns all fused together. acccmplished prior to being asstabled for stitching. The apparatus used to fuse Fusing of the cord, wewing and tape shall be 4 Provided by
13、IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,- I MIL-B-44418 83 9999906 0472843 4 I MIL-B-44418 (a) i 3.3.3 Stitchinu, machine. 3.3.3.1 Type s of stitchinq. All stitch types, except bartacking, shall conform to FED-SIP751 as follows: For all stitching except -
14、 Type 301, 5 to 7 stitches per inch zig-zag stitching and stitching indicated by “ZV1 on drawings For stitching indicated - Type 401, 5 to 7 stitches per inch - Chain portion of stitching shall not appear on by “Z“ on drawings outside of tent or cover For bartacking - Bartack, length as specified on
15、 drawings 1/8 inch in width (bight) and shall be free of thread breaks and loose-stitching 3.3.3.2 Wead breaks. Thread breaks in stitching shall be overstitched not less than 1 inch at each break on stitch type 301; and not less than 1-1/2 inches at each break on stitch type 401. shall be overstitch
16、ed with stitch type 301. inspection shall be repaired by overstitching the existing stitching starting from a distance of 1 inch beyond the break, across the defective area, to a distance of 1 inch beyorid the break. required to be backstitched. Thread breaks, in type 401 Thread breaks noted during
17、The ends of repair stitching are not 3.3.3.3 Stitchinu ends. The ends of type 301 stitching shall be overstitched not less than 1 inch except where ends are turned under in a han or held dawn by other stitching. autkiatically on stitch patterns such as box, box with cross-stitch, “W1 stitching or st
18、raight line tacking, at least three tying, overlapping, or back stitches shall be used to secure the ends of stitching. 3.3.3.4 skim stitches. TM or more consecutively skipped stitches occurring in types 301 stitching shall be overstitched not less than 1 inch. Any skipped stitches in type 401 stitc
19、hing shall be overstitched not less than 1-1/2 inches. Skipped stitches in 401 stitching shall be overstitched with type 301 stitching. Skipped stitches noted during inspection shall be repaired as specified for thread breaks. (See 3.3.3.2). Where 301 stitching is performed 3.3.3.5 Wrication of thre
20、ad. The addition of any lubrication to the polyester sewing thread prior to or during the sewing operations is prohibited. 5 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MI-B-444 18 (GL) 3.3.3.6 Automatic stitching. Autanatic stitching mchines may
21、 be used to perfom any of the required stitch pattern provided the requirements of the stitch pattern, stitches per inch, size and typ of thread are met, and at least three or more tying, overlapping or backstitches are used to secure the ends of the stitching. 3.3.3.7 Thread ends. All thread ends t
22、hat are visible on the finished item shall be trhned to a length of not mre than 1/2 inch. 3.3.3.8 Stitchina marq ins. unless otherwise specified, all stitch margins shall be 1/8 inch +1/16 -0 inch. 3.3.4 Eblicinq of cloth. There shall be no splicing of fabric. The number of panel seams shall not ex
23、ceed the requirements specified on the applicable drawings. 3.3.5 Settinq of qrwmie ts. smaller than the outside-diamter of the gromnet barrel so that the barrel must be forced through the hole. without cutting the materials. water through the stitching on the boot wall assemblies when they are test
24、ed as specified in 4.5.1. thread has been utilized and that no lubrication has been added to the polyester thread prior to or during the sewing operation. as a result of failure of the cup test and when authorized by the contracting officer, shall be performed by treating me exposed stitching on the
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILB444181991BOOTWALLFABRICASSEMBLIESSTANDARDIZEDINTEGRATEDCOMMANDPOSTSYSTEMSICPS 标准化 联合 指挥系统 SICPS

链接地址:http://www.mydoc123.com/p-440881.html