1、 A-A-59893 17 October 2012 COMMERCIAL ITEM DESCRIPTION 1,3,5-TRICHLOROBENZENE (TCB), CAS # 108-70-3 The General Services Administration has authorized the use of this commercial item description, for all federal agencies. 1. SCOPE 1.1 Scope. This commercial item description covers 1,3,5-trichloroben
2、zene (TCB). 2. SALIENT CHARACTERISTICS 2.1 Material. The material shall be 1,3,5-trichlorobenzene (TCB) meeting the following requirements: a) Color: White to off-white b) Form: The TCB may be supplied as a cast solid in a suitable container or as a granulated, flaked, or pelletized material c) Comp
3、ound identification: FTIR spectral profile to correspond that of pure material d) Purity: 98% minimum, by HPLC or GC area count e) Insoluble Material: 0.2 wt% max. f) Melting point: 62C minimum 2.2 Workmanship: The best commercial practice shall be used in the manufacture of this product. Procedures
4、 and controls shall be employed to prevent product contamination. There shall be no contamination (such as dirt, paint chips, wood, etc.) that is obvious and readily observable. In addition, the TCB shall be free of contaminants which are hazardous, corrosive, reactive, or metallic. AMSC N/A FSC 681
5、0 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited INCH-POUND Comments, suggestions, or questions on this document should be addressed to: Commander, U.S. Army ARDEC, ATTN: RDAR-QES-E, Picatinny Arsenal, New Jersey 07806-5000 or e-mailed to ARDECSTDZNconus.army.mil. S
6、ince contact information can change, you may want to verify the currency of this information using ASSIST Online database at https:/assist.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59893 2 3. REGULATORY REQUIREMENTS. 3.1 Safety and
7、 Health Practices. This standard does not purport to address all of the safety concerns, if any, associated with the use of the TCB material. It is the responsibility of whoever uses this standard to consult and establish appropriate safety and health practices and to determine the applicability of
8、regulatory limitations prior to use. 3.2 Manufacture Safety Data Statement. Manufacture Safety Data Statement shall be submitted in accordance with requirements as specified in the Code of Federal Regulation, Part 29-1910 (OSHA). (For shipment to foreign users, the Manufacture Safety Data Statement
9、may have to conform to the formatting and legislative requirements of the host country.) 4. QUALITY ASSURANCE PROVISIONS. 4.1 Product conformance. The product provided shall meet the salient characteristics of this Commercial Item Description. The Government reserves the right to require proof of su
10、ch conformance prior to the first delivery and thereafter as may be otherwise provided for under provisions of the contract. For TCB product which has been sold on the market for less than two years, the manufacturer shall have to demonstrate process stability and to verify product quality by submit
11、ting analysis data from the most recent 5 consecutive production batches. 4.2 Responsibility for inspection. Unless otherwise specified in the contract or purchase order, the supplier is responsible for the performance of inspections for the verification of all salient characteristics as specified i
12、n Section 2 of this CID. The supplier may use his own or any other facility suitable for the performance of the inspection requirements specified herein, unless otherwise specified in the contract or disapproved by the Government. The Government reserves the right to perform any inspections set fort
13、h in the CID where such inspections are deemed necessary to assure supplies and services conform to the prescribed requirements. 4.2.1 Bid sample submission. Unless otherwise specified, a sample of 100 grams of TCB shall be submitted for inspection and approval in accordance with the terms of the pr
14、ocurement contract. The sample will be subjected to any or all of the quality inspections listed in this CID for verification of compliance to any or all requirements listed in this CID. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59893 3 4.2
15、.2 Test and inspection results. The contractor shall provide a summary of product test results (or an appropriate form of document of analysis in accordance with acceptable industry practices) to verify conformance to the salient characteristics requirements. (See 2). The contractor shall maintain a
16、 traceable record of inspection test data adhering to general laboratory practices for future reference if required. 4.3 Sampling techniques and inspection procedures. When not specified in this CID, the TCB shall be inspected by using acceptable industry-wide sampling techniques and test procedures
17、 such as ASTM and ACS sampling and test procedures. Also, unless otherwise specified herein, all chemicals and reagents shall be ACS or Reagent Grade. Tests for High Performance Liquid Chromatography (HPLC) and the Fourier Transform Infrared Spectroscopy (FTIR) shall be performed as specified below.
18、 NOTE: The test description described below are not intended to be used as step-by-step laboratory procedures, rather they are intended to define the test methods used to obtain the required characteristics. The user should prepare their own laboratory procedures taking into consideration and comply
19、ing with all aspects of the following test method descriptions. In preparation of step-by-step laboratory procedures, the user should take into account safety precautions from the manufacturer, industry safety and health practices, and also determine the applicability of safety and environmental reg
20、ulatory limitations. The test descriptions below do not purport to address all the safety concerns, if any, associated with their use. It is the responsibility of the user of the procedure to establish appropriate safety and health practices and to determine the applicability of regulatory limitatio
21、ns prior to use. 4.3.1 Compound identification. A sample of TCB is given positive identification by an infrared scan from 4000 to 650 cm 4.3.1.1 Apparatus: A Perkin Elmer System One Fourier Transform Infrared (FTIR) spectrometer with a germanium lens and attenuated total reflectance (ATR) attachment
22、, or its equivalent. 4.3.1.2 Sample preparation: Use sufficient sample to cover the lens. 4.3.1.3 Results of examination. The spectral profile must correspond to the one shown below, Fig. 1. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59893 4
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYAA598932012135TRICHLOROBENZENETCBCASPDF

链接地址:http://www.mydoc123.com/p-440403.html