ANSI Z80.23-2008 For Ophthalmics C Corneal Topography Systems C Standard Terminology Requirements (VC)《眼科学.角膜形状体系.标准术语.要求》.pdf
《ANSI Z80.23-2008 For Ophthalmics C Corneal Topography Systems C Standard Terminology Requirements (VC)《眼科学.角膜形状体系.标准术语.要求》.pdf》由会员分享,可在线阅读,更多相关《ANSI Z80.23-2008 For Ophthalmics C Corneal Topography Systems C Standard Terminology Requirements (VC)《眼科学.角膜形状体系.标准术语.要求》.pdf(31页珍藏版)》请在麦多课文档分享上搜索。
1、AMERICAN NATIONAL STANDARDOLAfor Ophthalmics Corneal Topography Systems Standard Terminology, RequirementsANSI Z80.23-2008ANSIZ80.23-2008ANSIZ80.23-2008(Revision ofANSI Z80.23-1999)American National Standardfor Ophthalmics Corneal Topography Systems Standard Terminology, RequirementsSecretariatOptic
2、al Laboratories Association (until December 31, 2008)The Vision Council (after January 1, 2009)Approved August 4, 2008American National Standards Institute, Inc.Approval of an American National Standard requires review by ANSI that therequirements for due process, consensus, and other criteria for a
3、pproval havebeen met by the standards developer.Consensus is established when, in the judgement of the ANSI Board ofStandards Review, substantial agreement has been reached by directly andmaterially affected interests. Substantial agreement means much more thana simple majority, but not necessarily
4、unanimity. Consensus requires that allviews and objections be considered, and that a concerted effort be madetowards their resolution.The use of American National Standards is completely voluntary; theirexistence does not in any respect preclude anyone, whether he has approvedthe standards or not, f
5、rom manufacturing, marketing, purchasing, or usingproducts, processes, or procedures not conforming to the standards.The American National Standards Institute does not develop standards andwill in no circumstances give an interpretation of any American NationalStandard. Moreover, no person shall hav
6、e the right or authority to issue aninterpretation of an American National Standard in the name of the AmericanNational Standards Institute. Requests for interpretations should beaddressed to the secretariat or sponsor whose name appears on the titlepage of this standard.CAUTION NOTICE: This America
7、n National Standard may be revised orwithdrawn at any time. The procedures of the American National StandardsInstitute require that action be taken periodically to reaffirm, revise, orwithdraw this standard. Purchasers of American National Standards mayreceive current information on all standards by
8、 calling or writing the AmericanNational Standards Institute.American National StandardPublished byOptical Laboratories Association11096 Lee HighwayA101Fairfax, VA 22030-5039Copyright 2008 by Optical Laboratories AssociationAll rights reserved.No part of this publication may be reproduced in anyform
9、, in an electronic retrieval system or otherwise,without prior written permission of the publisher.Printed in the United States of AmericaDeveloped byThe Accredited Committee Z80 for Ophthalmic Standards -Optical Laboratories AssociationZ80 Secretariat11096 Lee HighwayA101Fairfax, VA 22030-5039iCont
10、entsPageForeword ii1 Scope and purpose 12 Normative references . 13 Terminology 24 Requirements . 85 Test methods and test devices. 86 Accompanying documents . 147 Marking. 14Tables1 Conic section descriptors . 72 Test surfaces for type testing . 103 Tolerance levels for test surface measurements 11
11、4 Analysis zones for accuracy and repeatability testing 13Figures1 Illustration of axial curvature, Ka, axial radius of curvature, ra, meridional curvature, Km, and meridional radius of curvature, rm62 Illustration of the corneal vertex and the apex 7AnnexesA Test surfaces for corneal topographers 1
12、5B Standardized displays for corneal topographers 17C Calculation of area weighting values 20D Preprocessing of axial elevation data prior to analysis ofpared data sets. 22iiForeword (This foreword is not part of American National Standard ANSI Z80.23-2008.)This American National Standard continues
13、to address the expressed needs of thosemembers of the ophthalmic community who use corneal topography in clinical set-tings, those who manufacture corneal topographers and those who teach others re-garding the use of the information collected by corneal topographers. In particularthere continues to
14、be a need for standardization of the terms and definitions used inthe field, for standardization of the methods used for characterizing the performanceof these instruments and for standardization of displays of corneal topographical in-formation. The experts who worked together to create this standa
15、rd felt that at thistime there is not sufficient consensus within the ophthalmic community to set perfor-mance requirements for these instruments beyond those for minimum area mea-sured and measurement sample density. The standard continues to addressstandardization of the methods for testing these
16、instruments, for assessing their per-formance, and for reporting the results thus obtained. The number and type of test surfaces to be used has been changed to include onlytest surfaces for which the results can be verified. When these surfaces are tilted orrotated the expected surface measurements
17、are easy to predict. These surfaceswere considered to be adequate as minimum verification surfaces for corneal topog-raphers; if a corneal topography system can measure these surfaces well, it will be aclinically useful instrument. The method for standardization of color maps has beenchanged in an e
18、ffort to improve the users ability to discern just-noticeable-differenc-es in corneal topography. The user always has the option of using a scale with lessresolution but with greater range, as long as the scale recommended in this docu-ment is available to be used.This standard was created by a spec
19、ial working group created by the Z80 Subcom-mittee on Ophthalmic Instruments and included experts in the field of corneal topog-raphy from the clinical, manufacturing and academic areas of the ophthalmiccommunity. This standard contains four annexes. Annex A is informative and is not considered tobe
20、 part of this standard. Annexes B, C, and D are normative and are considered to bepart of this standard.Suggestions for improvement of this standard will be welcome. Prior ro December31, 2008, any comments should be sent to the Optical Laboratories Association, P.O.Box 200, Merrifield, VA 22116-2000
21、. After January 1, 2009, comments should besent to The Vision Council, 1700 Diagonal Road, Suite 500, Alexandria, VA 22314.This standard was processed and approved for submittal to ANSI by the AccreditedStandards Committee on Ophthalmics, Z80. Committee approval of this standarddoes not necessarily
22、imply that all committee members voted for its approval. At thetime it approved this standard, the Z80 Committee had the following members:Thomas White, M.D., ChairmanQuido Cappelli, Vice-ChairmanRobert Rosenberg, O.D., SecretaryDaniel Torgersen, SecretariatOrganization Represented Name of Represent
23、ativeAdvance Medical Technologies Association Douglas J. FortunatoGlenn Davies (Alt.)Bernie Liebler (Alt.)Richard Courtney (Alt.)iiiOrganization Represented Name of RepresentativeAmerican Academy of OphthalmologyThomas C. WhiteGerhard Cibis (Alt.)Norman Lanphear (Alt.)Paul F. Vinger (Alt.)American A
24、cademy of Optometry .David S. LoshinAmerican Ceramic SocietyLyle RubinHerbert Hoover (Alt.)American Glaucoma Society.Steven J. Gedde Douglas J. Rhee (Alt.)American Optometric Association .William L. BrownWilliam J. Benjamin (Alt.)Robert Rosenberg (Alt.)Jeffrey Weaver (Alt.)American Society of Catara
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIZ80232008FOROPHTHALMICSCCORNEALTOPOGRAPHYSYSTEMSCSTANDARDTERMINOLOGYREQUIREMENTSVC 眼科学 角膜 形状 体系 标准

链接地址:http://www.mydoc123.com/p-439691.html