1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULSubject 746A (94, 746B, 746C, 746D, 1692,1694) April 6, 2015SUMMARY OF TOPICSThe following topics were discussed at the meeting of the Standards Technical Panel forPolymeric Materials:1. Inclined
2、 Plane Tracking Test (746A)2. Fixed Temperature Evaluation for Exceptionally Durable Materials (746B)3. Clarification Between Short Term Properties (UL746A) and Long Term Properties(UL746B) within Table 9.1 (746A)4. Starting Test Voltage for CTI (746A)5. Increase Generic Relative Thermal Index for P
3、EI (746B)6. Inclusion of UV and Water Immersion Testing in Table 9.1 for Addition, Deletion, orChange in Level of Colorant/pigment Loading (746A)7. Clearance Gauge for 50W (20 mm) Vertical Burning Test; V-0, V-1, or V-2 (94)8. Concentrations of UV-Stabilizer in Table 9.1 (746A)9. Accelerated Heat Ag
4、ing Evaluation by Thermal Analytical Tools In Accordance withIEC TS 60216-7-1 (746B)10. ANSI Reaffirmation Balloting During 2015 (1694)11. Publishing Cycles for Standards Covered Under the 746 STP12. Improvements Being Considered for the HAI Test Method (746A)13. HWI Test Procedures (746A)14. How th
5、e 746 STP Evaluates Proposals for New or Higher Generic RTIsA meeting of the Standards Technical Panel of UL for Polymeric Materials was held on March 25, 2015at 8:30 AM at the Rosen Centre Hotel in Orlando, Florida, USA. The purpose of the meeting was todiscuss items of interest with regard to UL 9
6、4, UL 746A, UL 746B, UL 746C and UL 1694 (there wereno proposal/discussion items received for UL 746D or UL 1692).The purpose of the STP meeting report is to briefly summarize discussions held during the meeting,and to document any resulting outcomes, including planned future action.UL COPYRIGHTED M
7、ATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULCALL TO ORDER, ANNOUNCEMENTS, INTRODUCTION OF MEMBERS, GUESTS, ANDOBSERVERSBrad Schmidt, the Chair of STP 746, welcomed the Standards Technical Panel (STP) members, guests,and public participants to the meeting.
8、 After asking if anyone had additional topics they would likediscussed at the end of the meeting, two additional items were requested. There was enough time toinclude them and they are shown in this report as Topics 12 and 13.The STP Chair reminds STP members that the ANSI STP Regulations that guide
9、 this process can befound at this link:http:/ AND REPORTS FROM THE STP PROJECT MANAGERProject Manager Ray Suga, requested that the attendees fill out a brief survey at the end of the meetingto indicate how the meeting went and areas for improvement. Also, the UL Patent Policy was brieflyexplained an
10、d attendees were reminded that they can find more-detailed information on the website:http:/ Project Manager and the STP Chair also made the STP aware of ULs Anti-trust Policy. Additionalinformation on this policy can be found at http:/ was also indicated that all standards development activities ta
11、ke place through ULs CSDS(Collaborative Standards Development System) and the website address for that is www.ul.csds.STP members were reminded that they should vote regularly on all proposals. If they dont considerthemselves to be experts on a particular subject matter it is preferable that they ca
12、st an Abstain voterather than not to vote at all. Specifically, above 50% of the membership must vote on each proposal (inorder to be in compliance with the STP Regulations regarding consensus).Members were reminded that, currently, two of the standards covered under this STP are coveredunder the Co
13、ntinuing Certification process. This explains why the format of proposals for UL 94 and UL746C might appear to be significantly different from that of UL 746A, UL 746B, UL 746D, UL 1692and UL 1694. The Continuing Certification process enables aspects, such as the impact of a proposal,to be discussed
14、 along with the safety aspects.It was noted that a staffing change is occurring at UL. The UL representative on the STP will now bePrasad Shankarappa and he will replace No Navarro who has served on this STP for many years. TheSTP Roster will be revised shortly to accomplish this. As a result, any f
15、uture Proposal Requests thatare submitted into CSDS by UL will be authored by Prasad Shankarappa.The current balance of the STP was discussed at the meeting and is shown in the following table:APRIL 6, 2015SUBJECT 746A -2-UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION
16、 WITHOUT PERMISSION FROM ULInterest Category Number of Members Interest Category Number of MembersProducers 13 Government 0Testing V-0, V-1, or V-2 (94)DISCUSSIONProposal item submitted by: Koji Inoue, Teijin LimitedA proposal was introduced that would allow for the optional use of a clearance gauge
17、 attached to theburner for the Vertical burning test. The clearance gauge would enable the technician to consistentlymaintain the distance between the burner and the test specimen. The visual appearance of the blueflame may vary depending on the person or the degree of darkness in the test chambers.
18、 Thus, thatcould be one of the factors for the data deviation. It was suggested that use of the clearance gaugecould minimize the deviation between various technicians and between different laboratories. Currently,IEC Standard (IEC 60695-11-10) allows the optional use of a clearance gauge.The STP ge
19、nerally supported the proposal provided its use will be optional; however, it suggestedseveral areas for improvement. One such area is that current requirements in 5.2 of UL 94 (and alsoASTM standards) might currently prohibit burner barrel attachments. Possibly, such a gauge couldbe used (without c
20、onflict) if it was not attached to the barrel itself. Other member suggested that the useof the attachment would be a hindrance to technicians performing the V-2 tests: making it harder toavoid the flaming and dripping of the sample. Some people suggested that a study may be needed toaddress heat si
21、nk and other factors related to using an attachment.Koji Inoue will consider whether any revisions to his proposal are necessary based on the STPdiscussions and then can submit a Proposal Request in CSDS. The proposal will then be presented toSTP 746 for preliminary review and comment.8. Concentrati
22、ons of UV-Stabilizer in Table 9.1 (746A)DISCUSSIONDiscussion item submitted by: Jochen Endtner, Lanxess Deutschland GmbHThe technical background on polymer stabilization is a very difficult and complex scientific area and ofcourse cant be reduced to a short rationale. However, there are some basics:
23、 many stabilizers inpolymers work by quenching radicals and/or transforming aggressive hydroperoxides into more stableproducts. These kind of aggressive species may be created by both, heat, oxygen or UV-radiation. So,a differentiation between pure UV-stabilizers, pure heat-stabilizers, or pure anti
24、oxidants is only possiblefor some special species of stabilizer. As a consequence, it would make a lot of sense to align thethresholds for all kind of stabilizers that finally interact by avoiding aggressive radicals orhydroperoxides, independently from the method.Conversely, there are some UV-stabi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIUL746BBULLETIN2015ULSTANDARDFORSAFETYPOLYMERICMATERIALSLONGTERMPROPERTYEVALUATIONSPDF

链接地址:http://www.mydoc123.com/p-439513.html