ANSI UL 493-2007 UL Standard for Safety Thermoplastic-Insulated Underground Feeder and Branch-Circuit Cables (Ninth Edition Reprint with Revisions Through and Including October 26 .pdf
《ANSI UL 493-2007 UL Standard for Safety Thermoplastic-Insulated Underground Feeder and Branch-Circuit Cables (Ninth Edition Reprint with Revisions Through and Including October 26 .pdf》由会员分享,可在线阅读,更多相关《ANSI UL 493-2007 UL Standard for Safety Thermoplastic-Insulated Underground Feeder and Branch-Circuit Cables (Ninth Edition Reprint with Revisions Through and Including October 26 .pdf(43页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 493 Thermoplastic-Insulated Underground Feeder and Branch-Circuit Cables STANDARD FOR SAFETYUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION
2、 FROM ULUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Thermoplastic-Insulated Underground Feeder and Branch-Circuit Cables, UL 493 Ninth Edition, Dated June 1, 2007 Summary of Topics This revision to ANSI/UL 493
3、is being issued to reect the reaffirmation of the ANSI approval of the Standard. No technical changes have been made to the document. The revisions are substantially in accordance with Proposal(s) on this subject dated August 26, 2016. Text that has been changed in any manner or impacted by ULs elec
4、tronic publishing system is marked with a vertical line in the margin. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of U
5、L. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, inclu
6、ding loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price
7、 paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from a
8、ny error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. OCTOBER 26, 2016 UL 493 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL OCTOBER 26, 2016 UL 493 tr2 No Text on This Page
9、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL JUNE 1, 2007 (Title Page Reprinted: October 26, 2016) 1 UL 493 Standard for Thermoplastic-Insulated Underground Feeder and Branch- Circuit Cables First Edition February, 1957 Second Edition Aug
10、ust, 1968 Third Edition July, 1970 Fourth Edition July, 1975 Fifth Edition March, 1979 Sixth Edition February, 1983 Seventh Edition October, 1988 Eighth Edition December, 1995 Ninth Edition June 1, 2007 This ANSI/UL Standard for Safety consists of the Ninth Edition including revisions through Octobe
11、r 26, 2016. The most recent designation of ANSI/UL 493 as a Reaffirmed American National Standard (ANS) occurred on October 26, 2016. ANSI approval for a standard does not include the Cover Page, Transmittal Pages, or Title Page. Comments or proposals for revisions on any part of the Standard may be
12、 submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at https:/. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs
13、 Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. COPYRIGHT 2016 UNDERWRITERS LABORATORIES INC. ANSI/UL 493-2012 (R2016)UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION
14、 FROM UL JUNE 1, 2007 UL 493 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS INTRODUCTION 1 Scope .4 2 Units of Measurement .4 3 References 4 CONSTRUCTION 4 General 5 5 Conductors 5 6 Insulation 6 7 Assembly of
15、 Multiple-Conductor Cables .7 7.1 General 7 7.2 Circuit conductors 7 7.3 Grounding conductor 8 8 Outer Covering on Multiple-Conductor Cables .9 9 Assemblies That Include Single-Conductor Type UF Cables 14 10 Submersible Water-Pump Cable Constructions .14 PERFORMANCE 11 Separability 16 12 Continuity
16、16 13 Vertical Flame Test 17 14 Vertical-Tray Flame Test .17 15 Dielectric Voltage-Withstand Test 18 16 Tension and Elongation Test 19 17 Unwinding Test at Low Temperature .21 17.1 General .21 17.2 Preparation of specimens 21 17.3 Test equipment .21 17.4 Conduct of the test 22 17.5 Results 23 18 Con
17、ductor Pullout Test 23 19 Stability of Conguration Test .23 20 Impact Test .26 21 Crushing Resistance Test 28 22 Flow Test .29 23 Sunlight Resistance Test .30 MARKINGS 24 Details .30 JUNE 1, 2007 UL 493 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSI
18、ON FROM UL INTRODUCTION 1 Scope 1.1 These requirements cover 14 4/0 AWG single-conductor PVC-insulated and -jacketed underground feeder and branch-circuit cable and at multiple-conductor PVC-jacketed underground feeder and branch-circuit cables containing two or three 14 6 AWG PVC-insulated circuit
19、conductors with or without a grounding conductor. These Type UF cables are intended for use in accordance with Article 340 and other applicable parts of the National Electrical Code, ANSI/NFPA-70 in wiring systems operating at a potential of 600 V or less. Submersible water-pump cables and multiple-
20、conductor assemblies to which a type-letter designation is not assigned are also covered in these requirements. 1.2 Multiple-conductor cable that is marked UF-B has a 75C (167F) jacket and conductors with insulation of 90C (194F) dry and at least 60C (140F) wet locations. Multiple-conductor cable th
21、at is marked UF has a 60C (140F) jacket and conductors with insulation for 60C (140F) dry and wet locations. Single-conductor cable is marked UF and has an integral insulation and jacket for 60C (140F) dry and wet locations. The ampacity of all cables covered in these requirements is that of 60C (14
22、0F) conductors. 1.3 These requirements do not cover insulation other than PVC, round cables containing two or more circuit conductors, at cables containing more than three circuit conductors, or multiple-conductor cables containing circuit conductors larger than 6 AWG. 2 Units of Measurement 2.1 In
23、addition to being stated in the inch/pound units that are customary in the USA, each of the requirements in this standard is also stated in units that make the requirement conveniently usable in countries employing the metric system (practical SI). Equivalent although not necessarily exactly identic
24、al results are to be expected from applying a requirement in USA or metric terms. Equipment calibrated in metric units is to be used when a requirement is applied in metric terms. 3 References 3.1 Any undated reference to a code or standard appearing in the requirements of this standard shall be int
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIUL4932007ULSTANDARDFORSAFETYTHERMOPLASTICINSULATEDUNDERGROUNDFEEDERANDBRANCHCIRCUITCABLESNINTHEDITIONREPRINTWITHREVISIONSTHROUGHANDINCLUDINGOCTOBER26PDF

链接地址:http://www.mydoc123.com/p-439258.html