ANSI UL 2250-2017 UL Standard for Safety Instrumentation Tray Cable (Third Edition).pdf
《ANSI UL 2250-2017 UL Standard for Safety Instrumentation Tray Cable (Third Edition).pdf》由会员分享,可在线阅读,更多相关《ANSI UL 2250-2017 UL Standard for Safety Instrumentation Tray Cable (Third Edition).pdf(61页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 2250 Instrumentation Tray Cable STANDARD FOR SAFETYUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL NOT AUTHO
2、RIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Instrumentation Tray Cable, UL 2250 Third Edition, Dated March 30, 2017 SUMMARY OF TOPICS This new edition of ANSI/UL 2250 is being issued to revise requirements for metal coverings. The revisions ar
3、e substantially in accordance with Proposal(s) on this subject dated November 4, 2016. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior
4、 permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or simila
5、r damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever
6、exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees)
7、resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. MARCH 30, 2017 UL 2250 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL MARCH 30, 2017 UL 2250 tr2 No Tex
8、t on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL MARCH 30, 2017 1 UL 2250 Standard for Instrumentation Tray Cable First Edition December, 1996 Second Edition April, 2006 Third Edition March 30, 2017 This ANSI/UL Standard for Saf
9、ety consists of the Third Edition. The most recent designation of ANSI/UL 2250 as an American National Standard (ANSI) occurred on March 30, 2017. ANSI approval for a standard does not include the Cover Page, Transmittal Pages, and Title Page. Comments or proposals for revisions on any part of the S
10、tandard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at https:/. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any w
11、ay. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. COPYRIGHT 2017 UNDERWRITERS LABORATORIES INC. ANSI/UL 2250-2017UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PER
12、MISSION FROM UL MARCH 30, 2017 INSTRUMENTATION TRAY CABLE - UL 2250 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS INTRODUCTION 1 Scope .5 2 Units of Measurement .6 3 References.6 CONSTRUCTION 4 Materials .6 5
13、 Conductors.6 6 Size, Temper, and Assembly .7 7 Conductor Diameter and Cross-Sectional Area .7 8 Metal Coating 7 9 Separator 8 10 Joints.8 11 Resistance 8 12 Stranding 10 13 Insulation 10 13.1 Material and application .10 13.2 Properties .12 13.3 Thicknesses .13 13.4 Individual covering15 14 Optical
14、-Fiber Member(s) .15 15 Assembly 16 15.1 Optical-ber member(s) .16 15.2 Circuit and grounding conductors.16 15.3 Fillers .17 15.4 Binders .18 15.5 Shield.18 16 Overall Jacket .18 16.1 Material and application .18 16.2 Properties .20 16.3 Thicknesses .20 17 Metal Covering .22 17.1 General .22 17.2 Sm
15、ooth metal sheath .22 17.3 Welded and corrugated metal sheath .23 17.4 Extruded and corrugated metal sheath 24 17.5 Interlocked armor.24 18 Jacket over Metal Covering 25 PERFORMANCE 19 Continuity Test of Conductors 26 20 Heat Shock and Flexibility Tests 27 20.1 Heat shock 27 20.2 Flexibility test 28
16、 21 Deformation Test .29 22 Cold Bend Test of Insulation .30 23 Cold Bend Test of Complete Cable .31 MARCH 30, 2017 INSTRUMENTATION TRAY CABLE - UL 2250 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 24 Spark Test after Insulating .32 25 D
17、ielectric Voltage-Withstand Test .32 26 Insulation Resistance Test at 60.0F (15.6C) 33 27 Test Procedure for Determining the Multiplying-Factor Column for Adjusting Insulation Resistance .36 28 Long Term Insulation-Resistance Test in Water 38 29 Sunlight Resistance Test 39 30 Crushing Test for Cable
18、 Marked for Direct Burial .39 31 Water Absorption Test of Insulation in Direct-Burial Cable .40 32 Impact Test for Type ITC Cable Marked -ER .41 33 Crushing Test for Type ITC Cable Marked -ER .42 34 Changes in Construction.43 35 Vertical-Tray Flame Tests on Cables 43 35.1 General .43 35.2 UL test 44
19、 35.3 FT4/IEEE 1202 test 44 35.4 Vertical-tray re and smoke-release test for cables with -LS marking45 36 Copper Sulphate Test of Zinc Coating on Steel Strip for and from Interlocked Steel Armor 45 37 Tension Test of Interlocked Armor 47 38 Flexibility Test for Cable Having Interlocked Armor or a Sm
20、ooth or Corrugated Metal Sheath .49 39 Durability Test of Ink Printing.50 MARKINGS 40 Intervals .50 41 Coding 50 42 Information on or in the Cable 51 43 Information on the Tag, Reel, or Carton .53 44 Multiple Markings .54 45 Date of Manufacture 55 MARCH 30, 2017 INSTRUMENTATION TRAY CABLE - UL 2250
21、4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL INTRODUCTION 1 Scope 1.1 These requirements cover Type ITC instrumentation control cables consisting of two or more current-carrying copper or thermocouple alloy conductors with or without eit
22、her or both: a) Grounding conductor(s), bare or insulated, and b) One or more optical-ber members, all under an overall jacket. These electrical and composite electrical/optical-ber cables are intended for use (optical and electrical functions associated in the case of a hybrid cable) on circuits ra
23、ted 150 V or less and5Aorless in accordance with Article 727 and other applicable parts of the National Electrical Code (NEC). 1.2 These cables are rated 300 V but are not so marked. Cables for direct-burial are so marked. Jacketed Type ITC cables comply with one of the following 70,000 Btu/h (20.5
24、kW) vertical-tray ame tests: a) The UL test referenced in 35.2.1 35.2.2 of these requirements. These paragraphs apply the test method described as the UL Flame Exposure (smoke measurements are not applicable) in the Standard for Vertical-Tray Fire-Propagation and Smoke-Release Test for Electrical an
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIUL22502017ULSTANDARDFORSAFETYINSTRUMENTATIONTRAYCABLETHIRDEDITIONPDF

链接地址:http://www.mydoc123.com/p-439077.html