ANSI UL 1641-2015 UL Standard for Safety Installation and Classification of Residential Burglar Alarm Systems (Fifth Edition)《住宅防盗报警系统的安装和分类用安全性标准》.pdf
《ANSI UL 1641-2015 UL Standard for Safety Installation and Classification of Residential Burglar Alarm Systems (Fifth Edition)《住宅防盗报警系统的安装和分类用安全性标准》.pdf》由会员分享,可在线阅读,更多相关《ANSI UL 1641-2015 UL Standard for Safety Installation and Classification of Residential Burglar Alarm Systems (Fifth Edition)《住宅防盗报警系统的安装和分类用安全性标准》.pdf(26页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 1641 Installation and Classication of Residential Burglar Alarm SystemsUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTE
2、D MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Installation and Classication of Residential Burglar Alarm Systems, UL 1641 Fifth Edition, Dated January 26, 2015 Summary of Topics This new edition was issued to incorporate the
3、following changes: Revisions to 7.1 for the Standards to which control units may be evaluated Revisions to 8.1.2 for removal of NFPA 74 and adding Chapter 29 of NFPA 72 Revisions to 19.4 referencing codes after verication These revised requirements are substantially in accordance with Proposal(s) on
4、 this subject dated November 7, 2014. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as i
5、s without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings,
6、 loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardle
7、ss of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced
8、while purchaser is storing an electronic Standard on the purchasers computer system. The requirements in this Standard are now in effect, except for those paragraphs, sections, tables, gures, and/or other elements of the Standard having future effective dates as indicated in the note following the a
9、ffected item. The prior text for requirements that have been revised and that have a future effective date are located after the Standard, and are preceded by a SUPERSEDED REQUIREMENTS notice. JANUARY 26, 2015 UL 1641 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION
10、 WITHOUT PERMISSION FROM UL JANUARY 26, 2015 UL 1641 tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL JANUARY 26, 2015 1 UL 1641 Standard for Installation and Classication of Residential Burglar Alarm Systems First Edi
11、tion April, 1983 Second Edition April, 1989 Third Edition September, 1994 Fourth Edition February, 1999 Fifth Edition January 26, 2015 This ANSI/UL Standard for Safety consists of the Fifth Edition. The most recent designation of ANSI/UL 1641 as an American National Standard (ANSI) occurred on Janua
12、ry 26, 2015. ANSI approval for a standard does not include the Cover Page, Transmittal Pages, Title Page, or effective date information. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-
13、Line Collaborative Standards Development System (CSDS) at http:/. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain t
14、he sole and exclusive property of UL. COPYRIGHT 2015 UNDERWRITERS LABORATORIES INC. ANSI/UL 1641-2015UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL JANUARY 26, 2015 UL 1641 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FU
15、RTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS INTRODUCTION 1 Scope .4 2 Components 4 3 Units of Measurement .5 4 Undated References 5 5 Glossary .5 6 Overall Requirements .7 7 Control Units .7 EXTENT OF PROTECTION FOR RESIDENTIAL ALARMS 8 General 8 8.1 Details 8 8.2 Basic pr
16、otection 8 8.3 Expanded protection 8 9 Wiring .9 9.1 General .9 9.2 Running and fastening 9 9.3 Splices and connections .10 9.4 Connectors .10 9.5 Entrance to building and remote areas .10 10 Windows .10 11 Doors and Other Openings 11 12 Air Conditioners, Exhaust Fans, and Similar Units 12 13 Screen
17、s .13 14 Floor Mats .13 15 Intrusion Detection Devices 13 15.1 General .13 15.2 Photoelectric units 13 15.3 Motion detection units 14 15.4 Sound and vibration units .14 16 Shunts 14 17 Control Unit 14 INTERPRETATIONS 18 General 14 MAINTENANCE AND SERVICE 19 General 21 JANUARY 26, 2015 UL 1641 3UL CO
18、PYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL INTRODUCTION 1 Scope 1.1 These requirements apply to the installation of alarm protection products and devices connected to form a residential burglar alarm system. 1.2 These requirements include th
19、e criteria for classifying the extent of alarm protection at an individual residence as either basic protection or expanded protection. 1.3 A residential burglar alarm system may or may not have a remote connection to a central station, proprietary station, residential monitoring station, or police
20、station. If there is a remote connection, the signal receiving location shall comply with the requirements in the following standards, as applicable: a) The Standard for Central-Station Alarm Services, UL 827; b) The Standard for Proprietary Burglar Alarm Units and Systems, UL 1076; and c) The Stand
21、ard for Police Station Connected Burglar Alarm Units and Systems, UL 365. 1.4 Alarm systems covered by these requirements have a sounding device that may be mounted indoors or outdoors. 1.5 These systems comply with the requirements for Class 2 remote-control and signal circuits as dened by Article
22、725 of the National Electrical Code, NFPA 70. Systems using both re and burglary protection operate as dened by Article 760 of the National Electrical Code, NFPA 70. 1.6 The requirements assume that standard telephone operating practices may be used for leased or other lines connecting to a police o
23、r central station as dened by Article 800 of the National Electrical Code, NFPA 70. 2 Components 2.1 Except as indicated in 2.2, a component of a product covered by this standard shall comply with the requirements for that component. 2.2 A component is not required to comply with a specic requiremen
24、t that: a) Involves a feature or characteristic not required in the application of the component in the product covered by this standard, or b) Is superseded by a requirement in this standard. 2.3 A component shall be used in accordance with its rating established for the intended conditions of use.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIUL16412015ULSTANDARDFORSAFETYINSTALLATIONANDCLASSIFICATIONOFRESIDENTIALBURGLARALARMSYSTEMSFIFTHEDITION

链接地址:http://www.mydoc123.com/p-438948.html