ANSI UL 1047-2015 UL Standard for Safety Isolated Power Systems Equipment (Sixth Edition).pdf
《ANSI UL 1047-2015 UL Standard for Safety Isolated Power Systems Equipment (Sixth Edition).pdf》由会员分享,可在线阅读,更多相关《ANSI UL 1047-2015 UL Standard for Safety Isolated Power Systems Equipment (Sixth Edition).pdf(58页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 1047 Isolated Power Systems EquipmentUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURT
2、HER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Isolated Power Systems Equipment, UL 1047 Sixth Edition, Dated October 15, 2015 SUMMARY OF TOPICS The Sixth Edition of the Standard for Isolated Power Systems Equipment, UL 1047, has been issued to reect the reaff
3、irmation of the ANSI approval. No changes in requirements have been made. The requirements are substantially in accordance with Proposal(s) on this subject dated August 7, 2015. . All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any
4、form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness for any purpose.
5、 In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative has been ad
6、vised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against an
7、y loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. OCTOBER 15, 2015 UL 1047 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FU
8、RTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL OCTOBER 15, 2015 UL 1047 tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL OCTOBER 15, 2015 1 UL 1047 Standard for Isolated Power Systems Equipment First Edi
9、tion August, 1976 Second Edition December, 1990 Third Edition March, 1995 Fourth Edition September, 2003 Fifth Edition October, 2010 Sixth Edition October 15, 2015 This ANSI/UL Standard for Safety consists of the Sixth Edition. The most recent designation of ANSI/UL 1047 as a Reaffirmed American Nat
10、ional Standard (ANS) occurred on October 15, 2015. ANSI approval for a standard does not include the Cover Page, Transmittal Pages and Title Page. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request
11、in ULs On-Line Collaborative Standards Development System (CSDS) at http:/. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shal
12、l remain the sole and exclusive property of UL. COPYRIGHT 2015 UNDERWRITERS LABORATORIES INC. ANSI/UL 1047-2010 (R2015)UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL OCTOBER 15, 2015 ISOLATED POWER SYSTEMS EQUIPMENT - UL 1047 2 No Text on T
13、his PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS INTRODUCTION 1 Scope .5 2 Glossary .5 3 General 6 3.1 Components .6 3.2 Units of measurement .7 3.3 Undated reference 7 CONSTRUCTION 4 General 7 5 Enclosure 7 6 Ventilation 8 7
14、 Connections for Wiring Systems 9 8 Corrosion Protection .9 9 Bases Insulating Material .9 10 Mounting of Parts .10 11 Current-Carrying Parts 13 12 Permanently Connected Equipment .13 13 Field-Wiring Terminals and Leads 13 14 Cord-Connected Equipment 16 14.1 General .16 14.2 Strain relief 16 14.3 Bu
15、shings 17 15 X-Ray Equipment .17 16 Wall Modular Units 17 17 Internal Wiring 18 18 Separation of Circuits .19 18.1 Factory installed 19 18.2 Field-installed Class 2 19 19 Field-Wiring Space 20 19.1 General .20 19.2 Wire bending space 20 20 Spacings 23 21 Isolation Transformers .26 22 Line Isolation
16、Monitor .28 23 Overcurrent Protection 28 24 Switches .29 25 Receptacles 29 26 Grounding Jacks and Cord Assemblies 30 27 Reference Grounding Bus .30 PERFORMANCE 28 Regulation .32 29 Temperature .33 30 Leakage Current 36 31 Dielectric Voltage-Withstand .44 32 Stability 45 OCTOBER 15, 2015 ISOLATED POW
17、ER SYSTEMS EQUIPMENT - UL 1047 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 33 Strength of Insulating Base and Supports 45 34 Abnormal Operation .45 35 Push-Back Relief .46 MANUFACTURING AND PRODUCTION TESTS 36 Production-Line Dielectric
18、 Voltage-Withstand .46 37 Production-Line Grounding Continuity .48 RATING 38 Details .48 MARKING 39 Details .48 APPENDIX A Standards for ComponentsA1 OCTOBER 15, 2015 ISOLATED POWER SYSTEMS EQUIPMENT - UL 1047 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT P
19、ERMISSION FROM UL INTRODUCTION 1 Scope 1.1 These requirements cover isolated power systems equipment rated 600 Vac or less, intended for installation and use in nonhazardous areas in health care facilities in accordance with the requirements in Article 517 of the National Electrical Code, NFPA 70, a
20、nd in the Standard for Health Care Facilities, NFPA 99. 1.2 These requirements cover isolated power centers, either cord-connected or permanently wired, consisting of a distribution panel that incorporates an isolation transformer, one or more isolated ungrounded secondary circuits terminating in in
21、tegrally mounted grounding-type receptacles, a reference grounding bus bar, and line isolation monitor. Isolated power centers may have provision for connection of grounding conductors to remote grounding jacks, the room bonding points, and patient equipment grounding points. A permanently wired iso
22、lated power center may also have provision for connection to remote receptacles or indicators. 1.3 These requirements cover convertible system units that facilitate a temporary conversion of the power supply for a power center from a grounded supply to an isolated supply. 1.4 These requirements cove
23、r isolated power panelboards that incorporate the same features as permanently wired isolated power centers except that: a) They may be supplied from remote isolation transformers, and b) The secondary isolated circuits are intended to be connected by conduit to remotely located receptacles. 1.5 The
24、se requirements cover wall modular units containing isolated power systems. 1.6 These requirements cover cord-connected isolated power centers, and panels intended to supply x-ray equipment only. 2 Glossary 2.1 For the purpose of this standard the following denitions apply. 2.2 CONVERTIBLE-SYSTEM UN
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIUL10472015ULSTANDARDFORSAFETYISOLATEDPOWERSYSTEMSEQUIPMENTSIXTHEDITIONPDF

链接地址:http://www.mydoc123.com/p-438790.html