ANSI ISEA 102-1990 American National Standard for Gas Detector Tube Units Short Term Type for Toxic Gases and Vapors in Working Environments《气体检测管装置.工作环境中毒气和毒蒸汽的快速检测型》.pdf
《ANSI ISEA 102-1990 American National Standard for Gas Detector Tube Units Short Term Type for Toxic Gases and Vapors in Working Environments《气体检测管装置.工作环境中毒气和毒蒸汽的快速检测型》.pdf》由会员分享,可在线阅读,更多相关《ANSI ISEA 102-1990 American National Standard for Gas Detector Tube Units Short Term Type for Toxic Gases and Vapors in Working Environments《气体检测管装置.工作环境中毒气和毒蒸汽的快速检测型》.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、A N S I / I S E A 102-1990 (R2015) American National Standard for Gas Detector Tube Units Short Term Type for Toxic Gases and Vapors in Working Environments ANSI/ISEA 102-1990 (R2015) American National Standard for Gas Detector Tube Units Short Term Type for Toxic Gases and Vapors in Working Environ
2、ments Secretariat International Safety Equipment Association Approved May 25, 1990 (reaffirmed February 26, 2015) American National Standards Institute, Inc. American National Standard An American National Standard implies a consensus of those substantially concerned with its scope and provisions. A
3、n American National Standard is intended as a guide to aid the manufacturer, the consumer, and the general public. The existence of an American National Standard does not in any respect preclude anyone, whether they have approved the standard or not, from manufacturing, marketing, purchasing, or usi
4、ng products, processes, or procedures not conforming to the standard. American National Standards are subject to periodic review and users are cautioned to obtain the latest editions. The American National Standards Institute does not develop standards and will in no circumstances give an interpreta
5、tion of any American National Standard. Moreover, no persons shall have the right or authority to issue an interpretation of an American National Standard in the name of the American National Standards Institute. CAUTION NOTICE: This American National Standard may be revised or withdrawn at any time
6、. The procedures of the American National Standards Institute require that action be taken to reaffirm, revise, or withdraw this standard no later than five years from the date of publication. Purchasers of American National Standards may receive current information on all standards by calling or wr
7、iting the American National Standards Institute. Published by International Safety Equipment Association 1901 N. Moore Street, Suite 808, Arlington, VA 22209 Copyright 1990 by International Safety Equipment Association All rights reserved. No part of this publication may be reproduced in any form, i
8、n an electronic retrieval system or otherwise, without the prior written permission of the publisher. Printed in the United States of America FOREWORD (This foreword is not part of American National Standard ANSI/ISEA 102-1990) This standard has been drafted to establish a voluntary standard for gas
9、 detector tube units. The standard was developed from the National Institute for Occupational Safety and Health (NIOSH), originally titled 42 Code of Federal Regulations 84-1973. Its use was discontinued in recent years. The purpose of this standard is to provide a means of continual testing of gas
10、detector tube units and components for accurate performance in working environments, by determining the concentration of toxic gases and vapors. This standard was processed and approved for submittal to ANSI by the Canvass Method. The following organizations recognized as having an interest in the s
11、tandardization of diffusive sampling devices were contacted prior to the approval of this standard. Inclusion in this list does not necessarily imply that the organization concurred with the submittal of the proposed standard to ANSI. AFL-CIO International Chemical Workers Union Alliance for America
12、n Insurers Matheson Gas Products American Gas Association Mobil Oil Corporation American Industrial Hygiene Association National Fire Protection Association American Iron and Steel Institute American Mining Congress National Institute for Occupational Safety and Health American Petroleum Institute N
13、ational Safety Council Bituminous Coal Operators Association Occupational Safety and Health Administration Chemical Manufacturer Association Oil, Chemical and Atomic Workers Union Compressed Gas Association Sensidyne, Inc. Edison Electric Institute United Auto Workers Hazardous Material Research Cen
14、ter United Mine Workers Industrial Health Foundation United Steel Workers Industrial Safety Equipment Association U.S. Department of Labor Instrument Society of America International Brotherhood of Electrical Workers Suggestions for the improvement of this standard will be welcome. They should be se
15、nt to the ISEA, 1901 No. Moore Street, #808, Arlington, VA 22209, iseasafetyequipment.org. Contents SECTION PAGE 1. Purpose 5 2. Referenced Standards .5 3. Definitions 5 4. Required Information 6 5. Construction and Performance Requirements .7 5.1 General Requirements 7 5.2 Length of Stain Type Dete
16、ctor Tubes .7 5.3 Color Comparison Type Detector Tubes .7 5.4 Calibration .8 6. Sampling Pumps 8 7. Quality Assurance 9 7.1 Sampling Plan .9 7.2 Acceptable Quality Level .9 7.3 Inspection Levels 9 Appendix Recommendation and Precaution concerning Gas Detector Tube Unit Use 10 ANSI/ISEA 102-1990 (R20
17、15) 5 American National Standard for Gas Detector Tube Units Short Term Type for Toxic Gases and Vapors in Working Environments 1. Purpose This standard sets forth the performance requirements for gas detector tube units and components, which are used to determine the concentrations of toxic gases a
18、nd vapors in working environments. 2. Referenced Standards This standard is intended to be used with the following standards: MIL-STD-105E, 10 May 1989, Military Standard, Sampling Procedures and Tables for Inspection by Attributes1 MIL-STD-414, 11 June 1957, Military Standard, Sampling Procedures a
19、nd Tables for Inspection by Variables for Percent Defective1 3. Definitions batch. A quantity of material defined as lot or batch in MIL-STD-105D, 1989, and MIL-STD-414, 1957. component. Any gas detector tube, sampling pump, or other device that changes the nature of the contaminant so that it may b
20、e measured by the tube, and is designed to operate as a constitute of the tube unit in such a way that the entire unit meets the requirements of this standard. contaminant. A specific chemical substance, usually a toxic gas or vapor, appearing in a workplace air environment. 1 Available from the Gov
21、ernment Printing Office, Washington, DC 20402. cross-sensitive gas or vapor. A gas or vapor that produces a stain similar to that obtained from presence of the contaminant. expiration date. The date until which tubes from the batch shall meet the requirements of this standard, if stored from time of
22、 manufacture according to the storage instructions. gas detector tube. A tube containing a chemically impregnated material which indicates the concentration of the contaminant or group of contaminants in the air by means of a chemically produced color change. Length-of-stain tubes indicate contamina
23、nt concentration by the length of stained formed. Color-comparison tubes indicate concentration by the color or intensity of the stain when compared to measurement standards. Group-type gas detector tube units are those designed and manufactured to measure more than one contaminant. independent tube
24、 reader. A person measuring the length of stain or comparing the color or intensity of stain in a tube unit, in accordance with the instructions furnished by the manufacturer, who is not aided by another person in reading the tube, has no knowledge of other reader results, and has no prior knowledge
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIISEA1021990AMERICANNATIONALSTANDARDFORGASDETECTORTUBEUNITSSHORTTERMTYPEFORTOXICGASESANDVAPORSINWORKINGENVIRONMENTS

链接地址:http://www.mydoc123.com/p-437032.html