ANSI INCITS 381-2009 Information Technology C Finger Image Based Data Interchange Format.pdf
《ANSI INCITS 381-2009 Information Technology C Finger Image Based Data Interchange Format.pdf》由会员分享,可在线阅读,更多相关《ANSI INCITS 381-2009 Information Technology C Finger Image Based Data Interchange Format.pdf(58页珍藏版)》请在麦多课文档分享上搜索。
1、American National StandardDeveloped byfor Information Technology Finger Image BasedData Interchange FormatINCITS 381-2009INCITS 381-2009INCITS 381-2009Revision ofINCITS 381-2004American National Standardfor Information Technology Finger Image BasedData Interchange FormatSecretariatInformation Techno
2、logy Industry CouncilApproved September 14, 2009 American National Standards Institute, Inc.AbstractThis standard specifies an interchange format for the exchange of image-based fingerprint and palm printrecognition data. It defines the content, format, and units of measurement for such information.
3、 This stan-dard is intended for those identification and verification applications that require the use of raw or pro-cessed image data containing detailed pixel information.Approval of an American National Standard requires review by ANSI that therequirements for due process, consensus, and other c
4、riteria for approval havebeen met by the standards developer.Consensus is established when, in the judgement of the ANSI Board ofStandards Review, substantial agreement has been reached by directly andmaterially affected interests. Substantial agreement means much more thana simple majority, but not
5、 necessarily unanimity. Consensus requires that allviews and objections be considered, and that a concerted effort be madetowards their resolution.The use of American National Standards is completely voluntary; theirexistence does not in any respect preclude anyone, whether he has approvedthe standa
6、rds or not, from manufacturing, marketing, purchasing, or usingproducts, processes, or procedures not conforming to the standards.The American National Standards Institute does not develop standards andwill in no circumstances give an interpretation of any American NationalStandard. Moreover, no per
7、son shall have the right or authority to issue aninterpretation of an American National Standard in the name of the AmericanNational Standards Institute. Requests for interpretations should beaddressed to the secretariat or sponsor whose name appears on the titlepage of this standard.CAUTION NOTICE:
8、 This American National Standard may be revised orwithdrawn at any time. The procedures of the American National StandardsInstitute require that action be taken periodically to reaffirm, revise, orwithdraw this standard. Purchasers of American National Standards mayreceive current information on all
9、 standards by calling or writing the AmericanNational Standards Institute.American National StandardPublished byAmerican National Standards Institute, Inc.25 West 43rd Street, New York, NY 10036Copyright 2009 by Information Technology Industry Council (ITI)All rights reserved.No part of this publica
10、tion may be reproduced in anyform, in an electronic retrieval system or otherwise,without prior written permission of ITI, 1101 K Street NW, Suite 610, Washington, DC 20005. Printed in the United States of AmericaCAUTION: The developers of this standard have requested that holders of patents that ma
11、y berequired for the implementation of the standard disclose such patents to the publisher. However,neither the developers nor the publisher have undertaken a patent search in order to identifywhich, if any, patents may apply to this standard. As of the date of publication of this standardand follow
12、ing calls for the identification of patents that may be required for the implementation ofthe standard, no such claims have been made. No further patent search is conducted by the de-veloper or publisher in respect to any standard it processes. No representation is made or impliedthat licenses are n
13、ot required to avoid infringement in the use of this standard.iContentsPageForeword .ivIntroduction .ix1 Scope. 12 Conformance . 13 Normative references. 14 Terms and definitions. 25 Abbreviated terms 36 Data conversions . 46.1 Byte and bit ordering 46.2 Scan sequence 47 Image acquisition requiremen
14、ts. 47.1 Overview 47.2 Acquisition levels . 57.2.1 Scan resolution 57.2.2 Pixel depth . 57.2.3 Dynamic range. 67.3 Pixel aspect ratio 67.4 Grayscale data. 67.5 Image resolution 67.6 Fingerprint image location 68 Finger image record format 78.1 Single-subject records . 78.2 CBEFF format owner and typ
15、e codes 78.3 Record Structure 78.3.1 General record header. 78.3.1.1 Overview 78.3.1.2 Format identifier. 78.3.1.3 Version number 88.3.1.4 Record length. 88.3.1.5 CBEFF Product identifier . 88.3.1.6 Capture device ID 98.3.1.7 Image acquisition level. 98.3.1.8 Number of finger/palm image views. 98.3.
16、1.9 Image Compression algorithm. 98.3.1.10 Reserved 98.3.2 Finger record header . 108.3.2.1 Overview 108.3.2.2 Length of finger/palm data block 108.3.2.3 Finger/palm position. 108.3.2.4 Count of views . 11iiPage8.3.2.5 View number 118.3.2.6 Finger/Palm image quality . 118.3.2.7 Impression type . 118
17、.3.2.8 Horizontal line length . 118.3.2.9 Vertical line length . 118.3.2.10 Pixel despth . 148.3.2.11 Scale units . 148.3.2.12 Scan resolution (horizontal) . 148.3.2.13 Scan resolution (vertical) . 148.3.2.14 Image resolution (horizontal) . 148.3.2.15 Image resolution (vertical) . 148.3.2.16 Reserve
18、d . 148.3.2.17 Image data length 158.3.2.18 Finger/Palm image data. 158.4 Extended data 158.4.1 Extended data block function. 158.4.2 Extended data block structure . 158.4.2.1 Extended data block format . 158.4.2.2 Type identification code . 158.4.2.3 Length of data 168.4.2.4 Data section. 168.4.3 S
19、egmentation data format . 168.4.3.1 Segment algorithm and owner ID 168.4.3.2 Segmentation quality score . 168.4.3.3 Finger quality algorithm and owner ID . 168.4.3.4 Number of segments . 168.4.3.5 Finger segment data 178.4.3.5.1 Finger position . 178.4.3.5.2 Finger quality . 178.4.3.5.3 Number of co
20、ordinate pairs . 188.4.3.5.3.1 X-coordinate 188.4.3.5.3.2 Y coordinate. 188.4.4 Annotation data format 188.4.4.1 Number of annotations 188.4.4.2 Finger position . 198.4.4.3 Annotation Code 198.4.5 Comment data format 198.4.6 Vensor-defined data format . 19AnnexesA ISFIS image quality specifications
21、. 20B Finger image data record example 42C Bibliography . 44iiiPageFigure1 Order of scanned lines . 4Tables1 Image acquisition setting levels . 52 General record header . 83 Compression algorithm codes 104 Finger image header record. 125 Finger position codes, areas, and maximum dimensions 136 Palm
22、codes, areas, and maximum dimensions 137 Finger and palm impression types . 148 Extended Data Area Type codes . 159 Segmentation data . 1710 Annotation data 18ivForeword (This foreword is not part of American National Standard INCITS 381-2009.)This standard specifies an interchange format for the ex
23、change of image-based fin-gerprint and palm print recognition data. It defines the content, format, and units ofmeasurement for such information. This standard is intended for those identificationand verification applications that require the use of raw or processed image data con-taining detailed p
24、ixel information. This document contains three annexes. Annex A, which is considered part of thisstandard, is normative and describes image quality requirements specified by the im-age acquisition settings. Annex B is an informative annex. It provides an example ofthe use of this standard and is not
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIINCITS3812009INFORMATIONTECHNOLOGYCFINGERIMAGEBASEDDATAINTERCHANGEFORMATPDF

链接地址:http://www.mydoc123.com/p-435681.html