ANSI IEEE C57.12.21-1992 Requirements for Pad-Mounted Compartmental-Type Self-Cooled Single-Phase Distribution Transformers With High Voltage Bushings High-Voltage 34500 GRYD 19920.pdf
《ANSI IEEE C57.12.21-1992 Requirements for Pad-Mounted Compartmental-Type Self-Cooled Single-Phase Distribution Transformers With High Voltage Bushings High-Voltage 34500 GRYD 19920.pdf》由会员分享,可在线阅读,更多相关《ANSI IEEE C57.12.21-1992 Requirements for Pad-Mounted Compartmental-Type Self-Cooled Single-Phase Distribution Transformers With High Voltage Bushings High-Voltage 34500 GRYD 19920.pdf(17页珍藏版)》请在麦多课文档分享上搜索。
1、 The Institute of Electrical and Electronics Engineers, Inc.3 Park Avenue, New York, NY 10016-5997, USACopyright 2003 by the Institute of Electrical and Electronics Engineers, Inc.All rights reserved. Printed in the United States of America.Print:ISBN 0-7381-3624-7 SH95108PDF:ISBN 0-7381-3625-5 SS95
2、108No part of this publication may be reproduced in any form, in an electronic retrieval system or otherwise, without the prior written permission of the publisher.ANSI C57.12.21-1992American National StandardRequirements for Pad-Mounted, Compartmental-Type Self-Cooled,Single-Phase Distribution Tran
3、sformersWith High Voltage Bushings; High-Voltage, 34500 GRYD/19920 Volts and Below; Low-Voltage, 240/120 Volts; 167 kVA and SmallerApproved 5/7/92American National Standards Institute, Inc.Approval of an American National Standard requires verification by ANSI that the requirements for due process,
4、consensus, and other criteria for approval have been met by the standards developer. Consensus is established when, in the judgment of the ANSI Board of Standards Review, substantial agreement has been reached by directly and materially affected interests. Substantial agreement means much more than
5、a simple majority, but not necessarily unanimity. Consensus requires that all views and objections be considered, and that a concerted effort be made toward their resolution. The use of American National Standards is completely voluntary; their existence does not in any respect preclude anyone, whet
6、her he has approved the standards or not, from manufacturing, marketing, purchasing, or using products, processes, or procedures not conforming to the standards. The American National Standards Institute does not develop standards and will in no circumstances give an interpretation of any American N
7、ational Standard. Moreover, no person shall have the right or authority to issue an interpretation of an American National Standard in the name of the American National Standards Institute. Requests for interpretations shall be addressed to the secretariat or sponsor whose name appears on the title
8、page of this standard. CAUTION NOTICE: This American National Standard may be revised or withdrawn at any time. The procedures of the American National Standards Institute require that action be taken to reaffirm, revise, or withdraw this standard no later than five years from the date of approval.
9、Purchasers of American National Standards may receive current information on all standards by calling or writing the American National Standards Institute. Published by National Electrical Manufacturers Association 130 0 N. 17th Street, Rosslyn, Virginia 22209 Copyright 1996 National Electrical Manu
10、facturers Association All rights reserved. No part of this publication may be reproduced in any form, in an electronic retrieval system or otherwise, without prior written permission of the publisher. Printed in the United States of AmericaAmerican National Standard i ANSI C57.12.21- 1992 CONTENTS P
11、age Foreword . iv 1 Scope 1 2 References 1 2.1 General . 1 3 Ratings 2 3.1 Kilovolt-ampere ratings . 2 3.2 Voltage ratings and tap rat ings . 2 4 Basic lightning impulse insulation levels and dielectric test levels 3 5 Tests . 3 5.1 General . 3 5.2 Dielectric tests 3 6 Construction 3 6.1 General . 3
12、 6.2 Bushings and terminals 4 6.3 High- voltage and low-voltage compartments . 4 6.4 Instruction nameplate . 5 6.5 Oil preservation 5 6.6 Tanks 5 7 Storage and installation . 6 7.1 Storage . 6 7.2 Installation . 6 8 Other requirements that may be specified for some applications . 6 ii ANSI C57.12.21
13、- 1992 Foreword (This Foreword is not part of Amer ican National Standard C57.12.21 - 1992)The Accredited Standards Committee on Transformers, Regulators, and Reactors, C57, has for a number of years been developing and correlating standards on transformers and regulators. The data used in this work
14、 have been gathered from many sources, including the standards of the Institute of Electrical and Electronics Engineers and the National Electrical Manufacturers Association, reports of committees of the Edison Electric Institute, and others. This standard was p repared by the Working Group of the S
15、ubcommittee on Distribution Transformers, Overhead and Pad- Mounted, C57.12.2, and is a revision of the 1986 edition. Added to this revision are sections on storage and installation with emphasis being placed on the actual position when stored and the consideration of the angle of tilt when installe
16、d. At the time of approval, the Working Group members were as follows: Gerald A. Paiva, ChairA. Ghafourian M. Mingoia R. Stahara K. Hanus D. Peters J. Valdes J. Malloy R. Scheu D. Whitley This standard was processed and approved for submittal to ANSI by Accredited Standards Committee on Transformers
17、, Regulators, and Reactors, C57. Committee approval of the standard does not necessarily imply that all committee members voted for its approval. At the time it approved this standard, the C57 Committee had the following members: Chairman: P. J. Hopkinson, NEMA Delegation Vice Chairman: J. C. Thomps
18、on, EL High-Voltage, 34500 GRDY/19920 Volts and Below; Low-Voltage, 240/120 Volts; 167 kVA and Smaller 1 Scope This standard is intended for use as a basis for determining performance, interchangeability, and safety of the equipment covered, and to assist in the proper selection of such equipment. 1
19、.2 This standard covers certain electrical, dimensional, and mechanical characteristics and takes into consideration certain safety features of single-phase, 60 Hz, mineral- oil-immersed, self-cooled, pad-mounted, compartmental-type distribution transformers with high-voltage bushings. These transfo
20、rmers are rated 167 kVA and smaller, with high-voltages of 34500 GRD/19900 volts and below for operation between one phase and grounded neutral, and low-voltage of 240/120 volts. These transformers are generally used for step- down purposes from an underground primary cable supply. NOTERefer to late
21、st federal regulations concerning polychlorinated biphenyl (PCB) contaminations in transformers. 1.3 This standard covers bushing and terminal arrangements for both radial and loop feed systems. 1.4 This standard does not cover the electrical and mechanical requirements of any accessory devices that
22、 may be supplied with the transformer. 2 References 2.1 General All characteristics, definitions, terminology, voltage designations, and tests, except as otherwise specified herein, shall be in accordance with the following American Natio nal Standards (see 2.2): ANSI C57.12.00-1987, American Nation
23、al Standard Requirements for Overhead-Type Distribution Transformers, 500 kVA and Smaller; High-Voltage, 34,500 Volts and Below; Low Voltage, 7970/13800 Y Volts and Below. ANSI C57.12.20-1988, American National Standard Requirements for Overhead-Type Distribution Transformers, 500 kVA and Smaller; H
24、igh-Voltage, 34,500 Volts and Below; Low-Voltage, 7970/13800 Y Volts and Below. ANSI C57.12.28-1988, American National Standard for Switchgear and Transformers Pad- Mounted Equipment Enclosure Integrity . ANSI C57.12.70-1978 (Reaff. 1987), American National Standard Terminal Markings and Connections
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIIEEEC5712211992REQUIREMENTSFORPADMOUNTEDCOMPARTMENTALTYPESELFCOOLEDSINGLEPHASEDISTRIBUTIONTRANSFORMERSWITHHIGHVOLTAGEBUSHINGSHIGHVOLTAGE34500GRYD19920PDF

链接地址:http://www.mydoc123.com/p-435326.html