ANSI ICEA S-90-661-2012 CATEGORY 3 5 & 5e INDIVIDUALLY UNSHIELDED TWISTED PAIR INDOOR CABLES (WITH OR WITHOUT AN OVERALL SHIELD) FOR USE IN GENERAL PURPOSE AND LAN COMMUNICATION WI.pdf
《ANSI ICEA S-90-661-2012 CATEGORY 3 5 & 5e INDIVIDUALLY UNSHIELDED TWISTED PAIR INDOOR CABLES (WITH OR WITHOUT AN OVERALL SHIELD) FOR USE IN GENERAL PURPOSE AND LAN COMMUNICATION WI.pdf》由会员分享,可在线阅读,更多相关《ANSI ICEA S-90-661-2012 CATEGORY 3 5 & 5e INDIVIDUALLY UNSHIELDED TWISTED PAIR INDOOR CABLES (WITH OR WITHOUT AN OVERALL SHIELD) FOR USE IN GENERAL PURPOSE AND LAN COMMUNICATION WI.pdf(51页珍藏版)》请在麦多课文档分享上搜索。
1、 ICEA STANDARD FORCATEGORY 3, 5, & 5e INDIVIDUALLY UNSHIELDED TWISTED PAIR INDOOR CABLES (WITH OR WITHOUT AN OVERALL SHIELD) FOR USE IN GENERAL PURPOSE AND LAN COMMUNICATION WIRING SYSTEMS TECHNICAL REQUIREMENTSApproved by AMERICAN NATIONAL STANDARDS INSTITUTE June 22, 2012 Publication # ANSI/ICEA S
2、-90-661-2012 2012 by INSULATED CABLE ENGINEERS ASSOCIATION, Inc.ANSI/ICEA S-90-661-2012 ANSI/ICEA S-90-661-2012 STANDARD FOR CATEGORY 3, 5, & 5e INDIVIDUALLY UNSHIELDED TWISTED PAIR INDOOR CABLES (WITH OR WITHOUT AN OVERALL SHIELD) FOR USE IN GENERAL PURPOSE AND LAN COMMUNICATION WIRING SYSTEMS TECH
3、NICAL REQUIREMENTS Published By INSULATED CABLE ENGINEERS ASSOCIATION, INC. Post Office Box 1568 Carrollton, GA 30112, USA. 2012 by ICEA Approved: March 16, 2012 by Insulated Cable Engineers Association, Inc. Approved: June 22, 2012 by American National Standards Institute ANSI/ICEA S-90-661-2012 ii
4、 Copyrighted by the ICEA Contents may not be reproduced in any form without permission of the INSULATED CABLE ENGINEERS ASSOCIATION, INC. Copies of this publication may be obtained from: IHS 15 Inverness Way East Englewood, CO 80113-5776 USA Telephone: (800) 854-7179 ANSI/ICEA S-90-661-2012 iii NOTI
5、CE AND DISCLAIMER The information in this publication was considered technically sound by the consensus of persons engaged in the development and approval of the document at the time it was developed. Consensus does not necessarily mean that there is unanimous agreement among every person participat
6、ing in the development of this document. The Insulated Cable Engineers Association, Inc. (ICEA) standards and guideline publications, of which the document contained herein is one, are developed through a voluntary consensus standards development process. This process brings together persons who hav
7、e an interest in the topic covered by this publication. While ICEA administers the process and establishes rules to promote fairness in the development of consensus, it does not independently test, evaluate, or verify the accuracy or completeness of any information or the soundness of any judgements
8、 contained in its standards and guideline publications. ICEA disclaims liability for personal injury, property, or other damages of any nature whatsoever, whether special, indirect, consequential, or compensatory, directly or indirectly resulting from the publication, use of, application, or relianc
9、e on this document. ICEA disclaims and makes no guaranty or warranty, expressed or implied, as to the accuracy or completeness of any information published herein, and disclaims and makes no warranty that the information in this document will fulfill any of your particular purposes or needs. ICEA do
10、es not undertake to guarantee the performance of any individual manufacturer or sellers products or services by virtue of this standard or guide. In publishing and making this document available, ICEA is not undertaking to render professional or other services for or on behalf of any person or entit
11、y, nor is ICEA undertaking to perform any duty owed by any person or entity to someone else. Anyone using this document should rely on his or her own independent judgement or, as appropriate, seek the advice of a competent professional in determining the exercise of reasonable care in any given circ
12、umstances. Information and other standards on the topic covered by this publication may be available from other sources, which the user may wish to consult for additional views or information not covered by this publication. ICEA has no power, nor does it undertake to police or enforce compliance wi
13、th the contents of this document. ICEA does not certify, test, or inspect products, designs, or installations for safety or health purposes. Any certification or other statement of compliance with any health or safety-related information in this document shall not be attributable to ICEA and is sole
14、ly the responsibility of the certifier or maker of the statement. ANSI/ICEA S-90-661-2012 iv (page intentionally left blank)ANSI/ICEA S-90-661-2012 v FOREWORD ICEA Standards are published in the public interest and are intended to promote product uniformity and quality throughout the industry. Exist
15、ence of an ICEA publication does not in any respect preclude the manufacture or use of products not conforming to the Standard. The user of this Standard is cautioned to observe any applicable health or safety regulations and rules relative to the manufacture and use of cable made in conformity with
16、 this Standard. This Standard hereafter assumes that manufacture, testing, installation, and maintenance of cables defined by this Standard will be performed only by properly trained personnel using suitable equipment and employing appropriate safety precautions. Questions of interpretation of ICEA
17、Standards can only be accepted in writing, and the reply shall be provided in writing. Suggestions for improvements in this Standard are welcome. Questions and suggestions shall be sent to: Secretary Insulated Cable Engineers Association, Inc. Post Office Box 1568 Carrollton, GA 30117, U.S.A United
18、States of America This Standard was developed by the ICEA Communications Division, Copper Cable Section, whose membership consisted of technical experts from the manufacturing segment of the industry. It was approved by ICEA on March 16, 2012. The members of the ICEA Communications Division, Copper
19、Cable Section, who participated in this project, were: R. Gould D. Baker P. Fraley G. Dorna ANSI/ICEA S-90-661-2012 vi TABLE OF CONTENTS CONTENTS: SECTION PAGEACRONYMS, ABBREVIATIONS AND SYMBOLS . x 1. GENERAL 1.1 Purpose . 1 1.2 Scope 1 1.3 Definition Of Cable Types 2 1.4 Options and Information 2
20、1.5 Units and Tolerances . 3 1.6 References 3 1.7 Quality Assurance 3 1.8 Safety Considerations 3 1.9 Installation Precautions . 3 2. CONDUCTORS 2.1 Solid Conductors for Horizontal Cables, Backbone Cables . 4 2.1.1 Solid Conductors . 4 2.1.2 Tin Coated Conductors . 4 2.1.3 Conductor Size 4 2.1.4 Con
21、ductor Elongation 4 2.1.5 Factory Joints 4 2.2 Stranded Conductors for Patch Cordage . 4 2.2.1 Individual Strands 4 2.2.2 Metallically Bonded Conductors 4 2.2.3 Stranded Conductor Size 4 2.2.3.1 UTP 4 2.2.3.2 FTP . 5 2.2.4 Factory Joints 5 3. CONDUCTOR INSULATION 3.1 Insulation Material 5 3.1.1 Heav
22、y Metal Free Insulation 5 3.1.2 Low halogen Insulation 5 3.2 Insulation Dimensions, Colors, and Splices . 5 3.2.1 Dimensions for Horizontal and Backbone Cables. . 5 3.2.2 Dimensions for Patch Cordage 5 3.2.3 Colors 6 3.2.4 Color Systems 6 3.2.5 Splices . 6 ANSI/ICEA S-90-661-2012 viiTABLE OF CONTENT
23、S CONTENTS: SECTION PAGE 3.3 Insulation Physical Requirements 6 3.3.1 Adhesion of Solid Conductors 6 3.3.2 Elongation 6 3.3.3 Compression of Solid Conductors 7 3.3.4 Cold Bend 7 3.3.5 Shrinkback . 7 3.3.6 Heat Exposure (Aging) . 7 3.3.7 Aged Flexibility . 7 3.3.8 Heavy Metal Content 7 3.3.8 Halogen
24、Content 8 3.4 Twist Length and Color Coding . 8 3.4.1 Pairs . 8 3.4.2 Horizontal and Backbone Cables . 8 3.4.3 Patch Cordage . 8 3.4.4 Tight Twist Pairs. 8 4. CORE CONSTRUCTION 4.1 Core Layup 104.2 Binders 10 4.3 Core Wrap . 104.4 Ripcord 10 5. SHIELDS 5.1 Shielding System . 11 5.2 Shielding Materia
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIICEAS906612012CATEGORY355EINDIVIDUALLYUNSHIELDEDTWISTEDPAIRINDOORCABLESWITHORWITHOUTANOVERALLSHIELDFORUSEINGENERALPURPOSEANDLANCOMMUNICATIONWIPDF

链接地址:http://www.mydoc123.com/p-434937.html