ANSI ASTM F1867-2006 Standard Practice for Installation of Folded Formed Poly (Vinyl Chloride) (PVC) Pipe Type A for Existing Sewer and Conduit Rehabilitation.pdf
《ANSI ASTM F1867-2006 Standard Practice for Installation of Folded Formed Poly (Vinyl Chloride) (PVC) Pipe Type A for Existing Sewer and Conduit Rehabilitation.pdf》由会员分享,可在线阅读,更多相关《ANSI ASTM F1867-2006 Standard Practice for Installation of Folded Formed Poly (Vinyl Chloride) (PVC) Pipe Type A for Existing Sewer and Conduit Rehabilitation.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F1867 06 (Reapproved 2012)Standard Practice forInstallation of Folded/Formed Poly (Vinyl Chloride) (PVC)Pipe Type A for Existing Sewer and Conduit Rehabilitation1This standard is issued under the fixed designation F1867; the number immediately following the designation indicates the yea
2、r oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers the procedures for the rehabilitat
3、ionof sewer lines and conduits 4 in. (102 mm) to 18 in. (457 mm)in diameter by the insertion of a folded/formed PVC pipe thatis heated, pressurized, and expanded to conform to the wall ofthe original conduit forming a new structural pipe-within-a-pipe. This rehabilitation process can be used in a va
4、riety ofgravity applications such as sanitary sewers, storm sewers, andprocess piping.1.2 This practice is to be used with the material specified inSection 6 of Specification F1871.1.3 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematic
5、alconversions to SI units that are provided for information onlyand are not considered standard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health p
6、ractices and determine the applica-bility of regulatory limitations prior to use.1.5 There is no similar or equivalent ISO Standard.2. Referenced Documents2.1 ASTM Standards:2D638 Test Method for Tensile Properties of PlasticsD648 Test Method for Deflection Temperature of PlasticsUnder Flexural Load
7、 in the Edgewise PositionD790 Test Methods for Flexural Properties of Unreinforcedand Reinforced Plastics and Electrical Insulating Materi-alsD1600 Terminology forAbbreviated Terms Relating to Plas-ticsD1784 Specification for Rigid Poly(Vinyl Chloride) (PVC)Compounds and Chlorinated Poly(Vinyl Chlor
8、ide)(CPVC) CompoundsD2122 Test Method for Determining Dimensions of Ther-moplastic Pipe and FittingsF412 Terminology Relating to Plastic Piping SystemsF1417 Practice for Installation Acceptance of Plastic Non-pressure Sewer Lines Using Low-Pressure AirF1871 Specification for Folded/Formed Poly (Viny
9、l Chlo-ride) Pipe Type A for Existing Sewer and Conduit Reha-bilitation2.2 Uni-Bell Standard:UNI-B-5-89 Recommended Practice for the Installation ofPolyvinyl Chloride (PVC) Sewer Pipe33. Terminology3.1 DefinitionsDefinitions are in accordance with Termi-nology F412, and abbreviations are in accordan
10、ce with Termi-nology D1600, unless otherwise indicated. The abbreviationfor poly(vinyl chloride) plastics is PVC.3.1.1 The term TYPE A is not an abbreviation but rather anarbitrary designation for PVC compounds with a minimumvalue for modulus in tension as listed in 6.1 and a maximumvalue as defined
11、 by cell limit 1 of Specification D1784.3.2 Definitions of Terms Specific to This Standard:3.2.1 dimples (dimpling), nWhere a side connection meetsthe existing conduit, there is no support for the PVC pipeduring forming, causing a point of thermoplastic pipe expan-sion slightly beyond the existing p
12、ipe wall. This formation ofan external departure from the formed pipe wall is termeddimpling.3.2.2 flattened pipe, na flattened pipe has been manufac-tured and calibrated round, then subsequently cooled anddeformed into a flattened shape for coiling purposes. Later, atthe time of installation at the
13、 project site, the flattened pipe willbe formed into the folded shape when inserted into the existingsewer and conduit rehabilitation.1This standard is under the jurisdiction of Committee F17 on Plastic PipingSystems and is the direct responsibility of Subcommittee F17.67 on TrenchlessPlastic Pipeli
14、ne Technology.Current edition approved April 1, 2012. Published May 2012. Originallyapproved in 1998. Last previous edition approved in 2006 as F1867 06. DOI:10.1520/F1867-06R12.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org.
15、For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from Uni-Bell PVC PipeAssociation, 2711 LBJ Freeway, Suite 1000,Dallas, TX 75234, http:/www.uni-bell.org.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, W
16、est Conshohocken, PA 19428-2959. United States13.2.3 folded pipe, npipe that has been manufactured andcalibrated round, then subsequently cooled and deformed intoa folded shape for use in existing sewer and conduit rehabili-tation (see Fig. 1).3.2.4 formed field sample, nA formed field sample isform
17、ed when the folded pipe has been inserted into a mold pipeand expanded with steam heat and pressure3.2.5 formed pipe, na folded pipe that has been insertedinto an existing sewer or conduit and expanded with steam heatand pressure, and, if required by the manufacturer, with asqueegee device or simila
18、r device to provide a close fit to theexisting pipe (see Fig. 1).3.2.6 insertion point, nAn existing manhole, existingaccess shaft, or an excavation that serves as the point ofentrance for the folded pipe into the existing pipe.3.2.7 liner, nPVC formed pipe fully functional as a pipewithin a rehabil
19、itated pipe.3.2.8 termination point, nAn existing manhole, existingaccess shaft, or an excavated pit that serves as the point of exitof the folded pipe from the existing pipe.4. Significance and Use4.1 This practice is for use by designers, and specifiesregulatory agencies, owners, and inspection or
20、ganizations in-volved in the rehabilitation of non-pressure sewers and con-duits. Modifications may be required, depending on specificjob conditions, to establish a project specification. The manu-facturer of the product should be consulted for design andinstallation information. Industrial waste di
21、sposal lines shouldbe installed only with the specific approval of the cognizantcode authority, since chemicals not commonly found in drainsand sewers and temperatures in excess of 140 F (60 C) maybe encountered.5. Materials5.1 The folded/formed PVC liner pipe should be made fromPVC compound, meetin
22、g all the requirements for cell classi-fication 12111 as defined in Specification D1784 and withminimum physical properties as listed.NOTE 1If required by the user, chemical resistance tests will besupplied by the pipe manufacturer.Tensile Strength Test MethodD6383600 PSI (25 MPa)Tensile Modulus Tes
23、t MethodD638155 000 PSI (1069 MPa)Flexural Strength Test MethodD7904100 PSI (28 MPa)Flexural Modulus Test MethodD790145 000 PSI (1000 MPa)Heat Deflection Test MethodD648115 F (46 C)Temperature Tested at 264psi(2 MPa)NOTE 1This figure is intended only for clarification of terms specific to this pract
24、ice and shows a representative folded pipe shape. Other folded pipeshapes may meet the requirements of this practice.FIG. 1 Folder Pipe and Formed PipeClarification of TermsF1867 06 (2012)25.1.1 Compounds meeting the above minimum propertiesthat have different cell classifications because one or mor
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIASTMF18672006STANDARDPRACTICEFORINSTALLATIONOFFOLDEDFORMEDPOLYVINYLCHLORIDEPVCPIPETYPEAFOREXISTINGSEWERANDCONDUITREHABILITATIONPDF

链接地址:http://www.mydoc123.com/p-432938.html