ANSI ASTM F1786-1997 Standard Test Method for Performance of Braising Pans《烤肉炉性能试验方法》.pdf
《ANSI ASTM F1786-1997 Standard Test Method for Performance of Braising Pans《烤肉炉性能试验方法》.pdf》由会员分享,可在线阅读,更多相关《ANSI ASTM F1786-1997 Standard Test Method for Performance of Braising Pans《烤肉炉性能试验方法》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F1786 97 (Reapproved 2016) An American National StandardStandard Test Method forPerformance of Braising Pans1This standard is issued under the fixed designation F1786; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, th
2、e year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method evaluates the energy consumption andcooking performance of braising pans. The food serviceo
3、perator can use this evaluation to select a braising pan andunderstand its energy consumption and performance character-istics.NOTE 1Braising pans also are commonly referred to as tilting skillets.This test method uses the term braising pan in accordance with Specifi-cation F1047.1.2 This test metho
4、d is applicable to self-contained gas orelectric braising pans. The braising pan can be evaluated withrespect to the following, where applicable:1.2.1 Maximum energy input rate (10.2).1.2.2 Capacity (10.3).1.2.3 Heatup energy efficiency and energy rate (10.4).1.2.4 Production capacity (10.4).1.2.5 S
5、immer energy rate (10.5).1.2.6 Surface temperature uniformity, optional, (10.6).1.2.7 Pilot energy rate (10.7).1.3 The values stated in inch-pound units are to be regardedas standard. The SI units given in parentheses are for informa-tion only.1.4 This standard does not purport to address all of the
6、safety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2F1047 Specification for Fryi
7、ng and Braising Pans, TiltingTypeF1275 Test Method for Performance of Griddles2.2 ANSI Standard:2ANSI Z83.11 American National Standard for Gas FoodService Equipment2.3 ASHRAE Documents:3ASHRAE Guideline 2-1986 (RA90) Engineering Analysisof Experimental DataASHRAE Handbook of Fundamentals, “Thermody
8、namicProperties of Water at Saturation,” Chapter 6, Table 2,19893. Terminology3.1 Definitions:3.1.1 braising pan, nan appliance wherein heat is im-parted to food in a shallow-sided flat-bottomed vessel byconduction through the heated pan bottom.3.1.2 control electric energy, nthe electric energy, fo
9、rexample, for controls, fans, consumed by braising pans whoseprimary fuel source is not electricity, that is, gas. Controlelectric energy is measured and reported separately fromprimary fuel energy so that their respective fuel prices can beapplied to estimate energy costs.3.1.3 fill-to-spill capaci
10、ty, nthe maximum food capacity(gal) of the braising pan as determined by filling to the point ofoverflow.3.1.4 heatup energy, nenergy consumed by the braisingpan as it is used to heat the specified food product to a specifiedtemperature.3.1.5 heatup energy effciency, na quantity of energyimparted to
11、 the specified food product, expressed as a percent-age of energy consumed by the braising pan during the heatupevent.3.1.6 heatup energy rate, nthe average rate of energyconsumption (kBtu/h or kW) during the heatup energy effi-ciency test.3.1.7 maximum energy input rate, nthe peak rate (kBtu/hor kW
12、) at which a braising pan consumes energy, as measuredin this test method.1This test method is under the jurisdiction of ASTM Committee F26 on FoodService Equipment and is the direct responsibility of Subcommittee F26.06 onProductivity and Energy Protocol.Current edition approved Oct. 1, 2016. Publi
13、shed November 2016. Originallyapproved in 1997. Last previous edition approved in 2010 as F1786 97 (2010).DOI: 10.1520/F1786-97R16.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume informa
14、tion, refer to the standards Document Summary page onthe ASTM website.3Available from American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Inc. (ASHRAE), 1791 Tullie Circle, NE, Atlanta, GA30329, http:/www.ashrae.org.Copyright ASTM International, 100 Barr Harbor Drive, PO Box
15、C700, West Conshohocken, PA 19428-2959. United States13.1.8 nameplate energy input rate, nthe peak rate (kBtu/hor kW) at which a braising pan consumes energy, as stated bythe manufacturer.3.1.9 nameplate capacity, nthe food capacity (gal) of thebraising pan, as stated by the manufacturer.3.1.10 pilo
16、t energy rate, nthe rate of energy consumption(kBtu/h) by a gas braising pans standing pilot, where appli-cable.3.1.11 production capacity, nthe highest rate (lb/h) atwhich a braising pan can bring the specified food product to aspecified temperature.3.1.12 simmer energy rate, nthe rate (kBtu/h or k
17、W) atwhich a braising pan consumes energy while maintaining thespecified food product at a specified simmer temperature.3.1.13 surface temperature uniformity, nthe variation incooking surface temperature measured at several points acrossthe pan bottom.3.1.14 testing capacity, nthe capacity (gal) at
18、which thebraising pan is operated during the heatup and simmer tests,that is, 80 % of fill-to-spill capacity.4. Summary of Test Method4.1 Connect the braising pan to the appropriate meteredenergy source, and determine the energy input rate to confirmthat it is operating within 5 % of the nameplate e
19、nergy inputrate.4.2 Fill the braising pan to the point of overflow to deter-mine the fill-to-spill capacity. For subsequent tests, a smallervolume or testing capacity, is calculated to allow adequatefreeboard between the waterline and the lip of the pan.4.3 Set the braising pan to maximum input and
20、monitor as itheats water from 80F to 160F, which yields the heatup energyefficiency, heatup energy rate, and production capacity.4.4 Adjust the braising pan controls to maintain water at165F for 3 h, yielding the simmer energy rate.4.5 Monitor the surface temperature of the pan at severalpoints to d
21、etermine temperature uniformity (optional).4.6 When applicable, measure the energy required to main-tain the standing pilot for a gas appliance, and report pilotenergy rate.5. Significance and Use5.1 Use the maximum energy input rate test to confirm thatthe braising pan is operating within 5 % of th
22、e manufacturersrated input so that testing may continue. This test method alsomay disclose any problems with the electric power supply orgas service pressure. The maximum input rate can be useful tofood service operators for managing power demand.5.2 The capacity test determines the maximum volume o
23、ffood product the pan can hold and the amount of food productthat will be used in subsequent tests. Food service operatorscan use the results of this test method to select a braising pan,which is appropriately sized for their operation.5.3 Production capacity is used by food service operators tochoo
24、se a braising pan that matches their food output.5.4 Heatup energy efficiency and simmer energy rate allowthe operator to consider energy performance when selecting abraising pan.5.5 Use the surface temperature uniformity to select abraising pan suitable for griddling applications.5.6 Use the pilot
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIASTMF17861997STANDARDTESTMETHODFORPERFORMANCEOFBRAISINGPANS 烤肉 性能 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-432912.html