ANSI ASTM F1504-2014 Standard Specification for Folded Poly(Vinyl Chloride) (PVC) Pipe for Existing Sewer and Conduit Rehabilitation.pdf
《ANSI ASTM F1504-2014 Standard Specification for Folded Poly(Vinyl Chloride) (PVC) Pipe for Existing Sewer and Conduit Rehabilitation.pdf》由会员分享,可在线阅读,更多相关《ANSI ASTM F1504-2014 Standard Specification for Folded Poly(Vinyl Chloride) (PVC) Pipe for Existing Sewer and Conduit Rehabilitation.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F1504 14Standard Specification forFolded Poly(Vinyl Chloride) (PVC) Pipe for Existing Sewerand Conduit Rehabilitation1This standard is issued under the fixed designation F1504; the number immediately following the designation indicates the year oforiginal adoption or, in the case of rev
2、ision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This specification covers requirements and test methodsfor materials, dimensions, workmanship, fla
3、ttening resistance,impact resistance, pipe stiffness, extrusion quality, and a formof marking for folded (vinyl chloride) (PVC) pipe for existingsewer and conduit rehabilitation.1.2 Pipe produced to this specification is for use in non-pressure sewer and conduit rehabilitation where the foldedPVC pi
4、pe is inserted into and then expanded to conform to thewall of the original conduit forming a new structural pipe-within-a-pipe.NOTE 1For installation procedures refer to Practice F1947.1.3 This specification includes pipe made only from mate-rials specified in Section 6. This specification does not
5、 includepipe manufactured from reprocessed, recycled, or reclaimedPVC.1.4 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.5 The followi
6、ng precautionary statement pertains to thetest method portion only, Section 11, of this specification: Thisstandard does not purport to address all of the safety concerns,if any, associated with its use. It is the responsibility of the userof this standard to establish appropriate safety and healthp
7、ractices and determine the applicability of regulatory limita-tions prior to use.2. Referenced Documents2.1 ASTM Standards:2D618 Practice for Conditioning Plastics for TestingD790 Test Methods for Flexural Properties of Unreinforcedand Reinforced Plastics and Electrical Insulating Materi-alsD1600 Te
8、rminology forAbbreviated Terms Relating to Plas-ticsD1784 Specification for Rigid Poly(Vinyl Chloride) (PVC)Compounds and Chlorinated Poly(Vinyl Chloride)(CPVC) CompoundsF1947 Practice for Installation of Folded Poly (Vinyl Chlo-ride) (PVC) Pipe into Existing Sewers and ConduitsD2122 Test Method for
9、 Determining Dimensions of Ther-moplastic Pipe and FittingsD2152 Test Method for Adequacy of Fusion of ExtrudedPoly(Vinyl Chloride) (PVC) Pipe and Molded Fittings byAcetone ImmersionD2412 Test Method for Determination of External LoadingCharacteristics of Plastic Pipe by Parallel-Plate LoadingD2444
10、Test Method for Determination of the Impact Resis-tance of Thermoplastic Pipe and Fittings by Means of aTup (Falling Weight)F412 Terminology Relating to Plastic Piping SystemsF1057 Practice for Estimating the Quality of Extruded Poly(Vinyl Chloride) (PVC) Pipe by the Heat ReversionTechnique2.2 Feder
11、al Standard:3Fed. Std. No. 123 Marking for Shipment (Civil Agencies)2.3 Military Standard:3MIL-STD-129 Marking for Shipment and Storage3. Terminology3.1 GeneralAbbreviations used in this specification are inaccordance with Terminology D1600 and definitions are inaccordance with Terminology F412 unle
12、ss otherwise indicated.3.2 Definitions of Terms Specific to This Standard:3.2.1 folded pipepipe that has been manufactured in afolded shape or that is subsequently folded for use in existingsewer and conduit rehabilitation. See Fig. 1.3.2.2 rounded pipeA rounded pipe is a sample for testpurposes for
13、med when the folded pipe has been inserted into a1This specification is under the jurisdiction of ASTM Committee F17 on PlasticPiping Systems and is the direct responsibility of Subcommittee F17.67 onTrenchless Plastic Pipeline Technology.Current edition approved April 1, 2014. Published May 2014. O
14、riginallyapproved in 1994. Last previous edition approved in 2010 as F1504 10. DOI:10.1520/F1504-14.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Do
15、cument Summary page onthe ASTM website.3Available from DLA Document Services Building 4/D 700 Robbins AvenuePhiladelphia, PA 19111-5094 http:/quicksearch.dla.mil/*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Co
16、nshohocken, PA 19428-2959. United States1circular casing pipe and expanded with heat and pressure to fittightly to the casing pipe taking a circular cross section, inaccordance with Section 10. See Fig. 1.4. Significance and Use4.1 The requirements of this specification are intended toprovide folded
17、 pipe suitable for the rehabilitation of existingpipelines and conduits conveying sewage, process flow, andstorm water, under nonpressure conditions, through theheating, insertion, and expansion of the folded pipe.NOTE 2Industrial waste disposal lines should be installed only withthe specific approv
18、al of the cognizant code authority since chemicals notcommonly found in drains and sewers and temperatures in excess of140F (60C) may be encountered.5. Application of Materials5.1 The nominal folded PVC pipe sizes specified in Section8 are applicable for a range of original pipe inside diameters.Tab
19、le 1 lists the recommended ranges for each nominal size.6. Materials and Manufacture6.1 Basic MaterialsThe pipe shall be made from virginPVC compound meeting all the requirements for cell classifi-cations 12334, 13223, 32334, or 33223 as defined in Specifi-cation D1784.6.2 Rework MaterialClean rewor
20、k material, generatedfrom the manufacturers own PVC sewer pipe production maybe used by the same manufacturer provided that the reworkmaterial meets the requirements of 6.1 and that the pipeproduced meets all the requirements of this specification.Reworked material of intermixed cell classifications
21、 shall belabeled as the minimum cell classification of this specification,and labeled in accordance with 15.1.3.1. Reworked materialcontaining any copolymer materials shall be labeled as copo-lymer material.7. Other Requirements7.1 Pipe FlatteningThere shall be no evidence ofsplitting, cracking, or
22、breaking when the rounded pipe is testedin accordance with 11.3.7.2 Pipe Impact StrengthThe impact strength of therounded pipe shall not be less than the values given in Table 2when tested in accordance with 11.4.NOTE 3This test is intended only for use as a quality-control test, notas a simulated s
23、ervice test.7.3 Pipe StiffnessPipe stiffness values for the roundedpipe shall comply with Table 3 when tested in accordance with11.6.7.4 Extrusion QualityThe extrusion quality of the pipeshall be evaluated by both of the following test methods.7.4.1 Acetone ImmersionThe pipe shall not flake or dis-i
24、ntegrate when tested in accordance with 11.6.1.7.4.2 Heat ReversionThe extrusion quality shall be esti-mated by heat reversion method in accordance with 11.6.2.7.5 Flexural PropertiesFlexural modulus of elasticity val-ues for the rounded pipe shall comply with Table 4 when testedin accordance with 1
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
2000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIASTMF15042014STANDARDSPECIFICATIONFORFOLDEDPOLYVINYLCHLORIDEPVCPIPEFOREXISTINGSEWERANDCONDUITREHABILITATIONPDF

链接地址:http://www.mydoc123.com/p-432848.html