ANSI ASTM F1484-2015 Standard Test Methods for Performance of Steam Cookers.pdf
《ANSI ASTM F1484-2015 Standard Test Methods for Performance of Steam Cookers.pdf》由会员分享,可在线阅读,更多相关《ANSI ASTM F1484-2015 Standard Test Methods for Performance of Steam Cookers.pdf(24页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F1484 15 An American National StandardStandard Test Methods forPerformance of Steam Cookers1This standard is issued under the fixed designation F1484; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last re
2、vision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 These test methods evaluate the energy consumptionand cooking performance of steam cookers. The food serviceoperator can use
3、this evaluation to select a steam cooker andunderstand its energy consumption.1.2 These test methods are applicable to the following steamcookers: high-pressure, low-pressure, pressureless and vacuumsteam cookers (Specification F1217 Grades A, B, C and D);convection and non-convection steam cookers;
4、 steam cookerswith self-contained gas-fired, electric, or steam coil steamgenerators, and those connected directly to an external potablesteam source (Specification F1217 Styles i, ii, iii, and iv). Thesteam cookers will be tested for the following (where appli-cable):1.2.1 Maximum energy input rate
5、 (see 10.2).1.2.2 Preheat energy consumption and duration (see 10.3).1.2.3 Idle energy rate (see 10.5).1.2.4 Pilot energy rate (see 10.6).1.2.5 Frozen green pea cooking energy efficiency (see 10.8).1.2.6 Frozen green pea production capacity (see 10.8).1.2.7 Whole potato cooking energy efficiency (se
6、e 10.9).1.2.8 Whole potato production capacity (see 10.9).1.2.9 Water consumption (see 10.7, 10.9, and 10.10).1.2.10 Condensate temperature (see 10.8 and 10.9).1.2.11 Cooking uniformity (see 10.11).1.3 The values stated in inch-pound units are to be regardedas standard. The SI units given in parenth
7、eses are for informa-tion only.1.4 This standard may involve hazardous materials,operations, and equipment. It does not address all of the safetyconcerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety andhealth practices and det
8、ermine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D3588 Practice for Calculating Heat Value, CompressibilityFactor, and Relative Density of Gaseous FuelsF1217 Specification for Cooker, Steam2.2 ASHRAE Documents:3ASHRAE Handbook of Fundamentals
9、Thermal and RelatedProperties of Food and Food Materials, Chapter 30, Table1, 1989ASHRAE Handbook of Fundamentals ThermodynamicProperties of Water at Saturation, Chapter 6, Table 2, 19892.3 Other Document:4Development and Application of a Uniform Testing Proce-dure for Steam Cookers3. Terminology3.1
10、 Definitions:3.1.1 boiler, nself-contained vessel, separate from thecooking cavity, wherein water is boiled to produce steam forthe steam cooker. Also called a steam generator.3.1.2 condensate, nmixture of condensed steam and cool-ing water, exiting the steam cooker and directed to the floordrain.3.
11、1.3 cooking energy effciency, nquantity of energy im-parted to the specified food product expressed as a percentageof energy consumed by the steam cooker during the cookingevent.3.1.4 cooking energy rate, naverage rate of energy con-sumption (kBtu/h or kW) during the cooking energy efficiencytest. R
12、efers to any loading scenario in the green pea or potatoload tests.3.1.5 electric energy rate, nrefers to rate of electric energyconsumption (kW) by steam cookers whose primary fuelsource is not electricity (for example, gas). Electric energy is1These test methods are under the jurisdiction ofASTM C
13、ommittee F26 on FoodService Equipment and is the direct responsibility of Subcommittee F26.06 onProductivity and Energy Protocol.Current edition approved Nov. 1, 2015. Published February 2016. Originallyapproved in 1993. Last previous edition approved in 2012 as F1484 12. DOI:10.1520/F1484-15.2For r
14、eferenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American Society of Heating, Refrigerating and Air
15、Condition-ing Engineers, Inc., 1791 Tullie Circle, NE, Atlanta, GA 30329.4Available from the Food Service Technology Center, 12949 Alcosta Blvd.,#101, San Ramon, CA 94583.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1measured and re
16、ported separately from the primary fuel energyso that the respective fuel prices can be applied to estimateenergy costs.3.1.6 green pea load, n12 by 20 by 212 in. (300 by 500 by65 mm) perforated hotel pan filled with 8.0 6 0.01 lb (3.6 6.005 kg) of fresh-frozen, grade A, green peas.3.1.7 high-pressu
17、re steam cooker, nsteam cooker whereincooking compartment operates between 10 and 15 psig (Speci-fication F1217 Classification Grade C).3.1.8 idle energy rate, nrate of energy consumed by thesteam cooker while maintaining the boiler or reservoir at amanufacturer-defined operating pressure or tempera
18、ture withno cooking taking place.3.1.9 low-pressure steam cooker, nsteam cooker whereincooking compartment operates between 3 and 9.9 psig (Speci-fication F1217 Classification Grade B).3.1.10 maximum energy input rate, npeak rate at which anappliance consumes energy, typically reflected during prehe
19、at.3.1.11 pilot energy rate, nrate of energy consumption(kBtu/h) by a gas steam cookers standing pilot (if applicable).3.1.12 potato load, none 12 by 20 by 212 in. (300 by 500by 65 mm) perforated hotel pan filled with 50 6 2 fresh, whole,US No. 1, size B, red potatoes, weighing 8.0 6 0.2 lb (3.6 60.
20、1 kg).3.1.13 preheat, nprocess of bringing the steamer (boiler)water from city supply temperature to operating temperature(pressure).3.1.14 preheat duration, ntotal time required for preheat,from preheat initiation at controls to when the steam cooker isready to cook.3.1.15 preheat energy, namount o
21、f energy consumed bythe steam cooker during a preheat.3.1.16 pressureless steam cooker, nsteam cooker whereincooking compartment operates between 0 and 2.9 psig (Speci-fication F1217 Classification Grade A).3.1.17 production capacity, nmaximum rate (lb (kg)/h) atwhich steam cooker can bring the spec
22、ified food product to aspecified “cooked” condition.3.1.18 production rate, nrate (lb (kg)/h) at which steamcooker brings the specified food product to a specified“cooked” condition. Does not necessarily refer to maximumrate. The production rate varies with the loading scenario andthe amount of prod
23、uct being cooked.3.1.19 steam cooker, ncooking appliance wherein heat isimparted to food in a closed compartment by direct contactwith steam. The compartment can be at or above atmosphericpressure. The steam can be static or circulated.3.1.20 water consumption, nwater consumed by the steamcooker. In
24、cludes both water used in the production of steamand cooling water (if applicable) for condensing/cooling un-used steam.4. Summary of Test Method4.1 The maximum energy input rate is determined to checkwhether the steam cooker is operating properly. If the mea-sured input rate is not within 5 % of th
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIASTMF14842015STANDARDTESTMETHODSFORPERFORMANCEOFSTEAMCOOKERSPDF

链接地址:http://www.mydoc123.com/p-432840.html