ANSI ASTM E1693-1995 Standard Classification for Serviceability of an Office Facility for Protection of Occupant Assets《居住者资产保护办公设备的适用性分类》.pdf
《ANSI ASTM E1693-1995 Standard Classification for Serviceability of an Office Facility for Protection of Occupant Assets《居住者资产保护办公设备的适用性分类》.pdf》由会员分享,可在线阅读,更多相关《ANSI ASTM E1693-1995 Standard Classification for Serviceability of an Office Facility for Protection of Occupant Assets《居住者资产保护办公设备的适用性分类》.pdf(15页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E1693 95 (Reapproved 2012)An American National StandardStandard Classification forServiceability of an Office Facility for Protection ofOccupant Assets1, 2This standard is issued under the fixed designation E1693; the number immediately following the designation indicates the year ofori
2、ginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This classification covers pairs of scales for classifyingan a
3、spect of the serviceability of an office facility, that is, thecapability of an office facility to meet certain possible require-ments to protect occupant assets.1.2 Each pair of scales, shown in Figs. 1-8, printed side byside on a page, are for classifying one topic of serviceabilitywithin that asp
4、ect of serviceability. Each paragraph in anOccupant Requirement Scale (see Figs. 1-8) summarizes onelevel of serviceability on that topic that occupants mightrequire. The matching entry in the Facility Rating Scale (seeFigs. 1-8) is a translation of the requirement into a descriptionof certain featu
5、res of a facility that, taken in combination,indicate that the facility is likely to meet that level of requiredserviceability.1.3 The entries in the Facility Rating Scale (see Figs. 1-8)are indicative and not comprehensive. They are for quickscanning, to estimate approximately, rapidly, and economi
6、-cally, how well an office facility is likely to meet the needs ofone or another type of occupant group over time. The entriesare not for measuring, knowing, and evaluating how an officefacility is performing.1.4 This classification can be used to estimate the level ofserviceability of an existing f
7、acility. It can also be used toestimate the serviceability of a facility that has been plannedbut not yet built, such as one for which single-line drawingsand outline specifications have been prepared.1.5 This classification indicates what would cause a facilityto be rated at a certain level of serv
8、iceability, but it does notstate how to conduct a serviceability rating nor how to assigna serviceability score. That information is found in PracticeE1334. The scales in this classification are complementary toand compatible with Practice E1334. Each requires the other.2. Referenced Documents2.1 AS
9、TM Standards:3E631 Terminology of Building ConstructionsE1334 Practice for Rating the Serviceability of a Buildingor Building-Related FacilityE1679 Practice for Setting the Requirements for the Ser-viceability of a Building or Building-Related Facility2.2 ISO Documents.4ISO 6240 International Standa
10、rd, Performance Standards inBuildingContents and PresentationISO/DIS 7162 Draft International Standard, PerformanceStandards in BuildingContents and Format of Standardsfor Evaluation of PerformanceISO/DIS 7164 Draft International Standard, PerformanceStandards in BuildingDefinitions and Means of Exp
11、res-sion for the Performance of a Whole Building3. Terminology3.1 Definitions: For standard definitions of terms applicableto this classification, see Terminology E631.3.1.1 facility, na physical setting used to serve a specificpurpose. E6313.1.1.1 DiscussionA facility may be within a building, ora
12、whole building, or a building with its site and surroundingenvironment; or it may be a construction that is not a building.The term encompasses both the physical object and its use.3.1.2 facility serviceabilitythe capability of a facility toperform the function(s) for which it is designed, used, orr
13、equired to be used. E6313.1.2.1 DiscussionThe scope of this performance is of thefacility as a system, including its subsystems, components, andmaterials and their interactions, such as acoustical, hydrother-mal, air purity, and economic; and of the relative importance ofeach performance requirement
14、.3.1.3 offcea place, such as a room, suite, or building, inwhich business, clerical, or professional activities are con-ducted. E6311This classification is under the jurisdiction of ASTM Committee E06 onPerformance of Buildings and is the direct responsibility of Subcommittee E06.25on Whole Building
15、s and Facilities.Current edition approved April 1, 2012. Published April 2012. Originallyapproved in 1995. Last previous edition approved in 2005 as E1693 95 (2005).DOI: 10.1520/E1693-95R12.2Portions of this document are based on material originally prepared by theInternational Centre for Facilities
16、 (ICF) and r 1993 by ICF and Minister of PublicWorks and Government Services Canada. Their cooperation in the development ofthis standard is acknowledged.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMS
17、tandards volume information, refer to the standards Document Summary page onthe ASTM website.4Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshoho
18、cken, PA 19428-2959, United States.FIG. 1 Scale A.8.1 for Control of Access from Building Public Zone to Occupant Reception ZoneE1693 95 (2012)23.2 Definitions of Terms Specific to This Standard:3.2.1 hours of operation:3.2.1.1 active hoursthe time during which a facility isnormally fully occupied a
19、nd operational.3.2.1.2 normal working hoursthe time during the daywhen staff are normally at work, starting with the normalarrival in the morning of the first staff and ending with thenormal departure time of the last staff. This excludes the timeof an evening or night shift, the time when staff are
20、 workinglater than normal, weekends, and legal holidays.3.2.1.3 silent hoursthe period when a facility is essen-tially unoccupied, although security, cleaning, and buildingoperations staff may be present.3.2.1.4 transitional hoursthe time during the morningafter the first workers normally arrive unt
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIASTME16931995STANDARDCLASSIFICATIONFORSERVICEABILITYOFANOFFICEFACILITYFORPROTECTIONOFOCCUPANTASSETS

链接地址:http://www.mydoc123.com/p-432556.html