ANSI ASTM E1679-2013 Standard Practice for Setting the Requirements for the Serviceability of a Building or Building-Related Facility and for Determining What Serviceability is Pro.pdf
《ANSI ASTM E1679-2013 Standard Practice for Setting the Requirements for the Serviceability of a Building or Building-Related Facility and for Determining What Serviceability is Pro.pdf》由会员分享,可在线阅读,更多相关《ANSI ASTM E1679-2013 Standard Practice for Setting the Requirements for the Serviceability of a Building or Building-Related Facility and for Determining What Serviceability is Pro.pdf(17页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E1679 13 An American National StandardStandard Practice forSetting the Requirements for the Serviceability of a Buildingor Building-Related Facility, and for Determining WhatServiceability is Provided or Proposed1,2This standard is issued under the fixed designation E1679; the number im
2、mediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.INTRODUCTIONMo
3、st organizations and work groups have only a few generic types of functions, such as generalpurpose office functions, or office functions requiring special security provisions because receivingmany visitors, or having a mix of office and “dry” laboratory functions, and so on. For each typicalor gene
4、ric type of function, facilities are required to have a different mix of functional capabilities tosupport the activities of those who use, own, or manage that function.This document is a definitive procedure to (1) ascertain the profile of required levels of functionality(functional support) for a
5、specific occupant group, (2) ascertain the profile of levels of serviceability(functional capability) that are provided in an existing facility, or called for in the design for a facility,and (3) compare what is provided to what is required.To ascertain the profile provided by a facility, or the pro
6、file of an organizations requirements, thispractice uses scales that look like multiple choice questionnaires for discrete topics related to buildingsand their use. One set of scales is for user functional requirements (demand) and a matching set ofscales is for building serviceability (supply).For
7、each topic of required functionality (demand), the user of this practice employs a classificationscale called a “requirement scale” to set the level required. Each requirement scale contains severaldescriptions of required functionality for that topic, classified in a range from low to high, for exa
8、mple,from Level 0 to Level 9. For each topic of serviceability provided (supply), the user of this practiceemploys a classification scale called a “rating scale” to ascertain the level of serviceability that isfound in the facility. Each rating scale contains several descriptions of serviceability p
9、rovision for thattopic, classified in a range from low to high, for example, from Level 0 to Level 9.Each such scale, demand or supply, is used like a multiple choice questionnaire to select the levelof functionality or of serviceability. Overall required functionality is displayed as a profile of l
10、evels(that is, not as a single number) and may be presented as a bar chart. Similarly, overall serviceabilityprovided may be presented as a bar chart. When the two bar charts are compared (gap analysis) thecloseness of functional fit of a facility for an organization is displayed.When comparing the
11、requirement profile prepared by one organization with that prepared byanother organization, it is essential that both use the same set of requirement scales. Organizationsmay use an ASTM standard set of scales; they may create their own; or they may adapt ASTMstandard classification scales for speci
12、alized, internal application. The organization forgoes thepossibility of external comparison in the latter two cases.This standard practice is an updated version of Practice E1679, to which has been added theprovisions of the companion standard, Practice E1334. A whole family of scales which comply
13、withthis version of Practice E1679, for use in North America, has been standardized by ASTM, under thejurisdiction of ASTM Subcommittee E06.25 on Whole Buildings and Facilities. A version in Frenchwas created by Public Works and Government Services Canada. A set of scales in French, adapted forways
14、of building and managing facilities in France was created by the French public entity CentreScientific et Technique du Btiment (CSTB). All the ASTM scales are included in ASTM Standardsfor Whole Building Functionality and Serviceability, ASTM stock number WBDG2009 or lateredition. After Practice E13
15、34 and Practice E1679 were standardized, a version of the practice asmodified for use in other countries was created as ISO 11863.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States11. Scope1.1 This practice provides a definitive procedur
16、e for settingthe level of requirements of the users (functionality) for thefunctional capability of a building or building-related facility.1.2 This practice provides a definitive procedure for ratingthe level of functional capability (serviceability) provided byan existing building or building-rela
17、ted facility, or to beprovided according to the design for one.1.3 This practice provides a definitive procedure for creat-ing or adapting a set of classifications for establishing thelevels of functionality required of or the level of capabilityprovided by a building or building-related facility.1.
18、4 This practice can be used for setting the profile ofrequirements of an occupant group in an existing building orbuilding-related facility, or of a group planning to move andlooking at new accommodations to rent, buy, or build, and itcan be used to assess the suitability of their present facilities
19、.1.5 This practice can be used for setting the profile ofrequirements of an owner, facility manager, lender, or otherinvestor.1.6 This practice does not specify what would cause abuilding to be rated at a given level. That information is foundin classifications for specific topics of serviceability
20、thatcontain a set of rating scales.1.7 This practice is not intended to be used for regulatorypurposes.1.8 This practice contains the following information, in thesections indicated:SectionIntroduction 1Scope 1Referenced Documents 2Terminology 3Significance and Use 4Essence of the Approach 5Procedur
21、e for Setting the Profile of Required Functionality 6Procedure for Setting the Profile of Functional Capability for aBuilding or for Building-Related Facilities7Rating the Plans or Proposals for a New Building or for aRemodel or Rehabilitation Project8Keywords 9Rules for Setting Levels in a Scale An
22、nex A1Examples of Scales Appendix X1Steps for Setting the Functional Requirement Profile Appendix X2Steps for Setting the Facility Rating Profile Appendix X3Examples of Bar-Chart Profiles Appendix X4Example of Titles of Aspects, Topics and Features Appendix X5List of Common Types of Function Appendi
23、x X61.9 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applicabil-ity of regulatory limitations prior to use.2. Referenc
24、ed Documents2.1 ASTM Standards:3E631 Terminology of Building ConstructionsE1334 Practice for Rating the Serviceability of a Building orBuilding-Related Facility (Withdrawn 2013)4E1480 Terminology of Facility Management (Building-Related)2.2 International Standards:5ISO 11863 Buildings and Building-R
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIASTME16792013STANDARDPRACTICEFORSETTINGTHEREQUIREMENTSFORTHESERVICEABILITYOFABUILDINGORBUILDINGRELATEDFACILITYANDFORDETERMININGWHATSERVICEABILITYISPROPDF

链接地址:http://www.mydoc123.com/p-432553.html