1、Designation: D3874 13Standard Test Method forIgnition of Materials by Hot Wire Sources1This standard is issued under the fixed designation D3874; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number i
2、n parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method is intended to differentiate, in apreliminary fashion, among materials with respect to theirresistance to ignition because of
3、 their proximity to electrically-heated wires and other heat sources.21.2 This test method applies to molded or sheet materialsavailable in thicknesses ranging from 0.25 to 6.4 mm (0.010 to0.25 in.).1.3 This test method applies to materials that are rigid atnormal room temperatures. That is, it appl
4、ies to materials forwhich the specimen does not deform during preparation,especially during the wire-wrapping step described in 10.1.Examples of deformation that render this test method inappli-cable include:1.3.1 Bowing, in either a transverse or a longitudinaldirection, or twisting of the specimen
5、, during the wire-wrapping step, to a degree visible to the eye.1.3.2 Visible indentation of the wrapped wire into thespecimen.1.4 The values stated in SI units are to be regarded as thestandard. The inch-pound units given in parentheses are forinformation only. (See SI10 for further details.)1.5 Th
6、is test method measures and describes the response ormaterials, products, or assemblies to heat and flame undercontrolled conditions, but does not by itself incorporate allfactors required for fire hazard or fire risk assessment of thematerials, products, or assemblies under actual fire conditions.1
7、.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.1.7 Fire testing
8、 is inherently hazardous. Adequate safe-guards for personnel and property shall be employed inconducting these tests.NOTE 1Although this test method and IEC 60695-2-20, differ inapproach and in detail, data obtained using either are technically equiva-lent.2. Referenced Documents2.1 ASTM Standards:3
9、D1711 Terminology Relating to Electrical InsulationE176 Terminology of Fire StandardsIEEE/ASTM SI-10 American National Standard for MetricPractice2.2 IEC Standards:IEC 60695-2-20 Fire Hazard TestingSection 20: Glowing/Hot-wire Based Test Methods, Hot-wire Coil IgnitabilityTest on Materials4IEC 60695
10、-4 Fire Hazard TestingPart 4: TerminologyConcerning Fire Tests42.3 ISO StandardsISO 13943 Fire SafetyVocabulary53. Terminology3.1 Definitions:3.1.1 Use Terminology E176 and ISO 13943 and IEC60695-4 for definitions of terms used in this test method andassociated with fire issues. Where differences ex
11、ist indefinitions, those contained in Terminology E176 shall be used.Use Terminology D1711 for definitions of terms used in thistest method and associated with electrical insulation materials.3.2 Definitions of Terms Specific to This Standard:3.2.1 ignition, ninitiation of flaming produced by combus
12、-tion in the gaseous phase that is accompanied by the emissionof light.1This test method is under the jurisdiction of ASTM Committee D09 onElectrical and Electronic Insulating Materials and is the direct responsibility ofSubcommittee D09.17 on Fire and Thermal Properties.Current edition approved Nov
13、. 1, 2013. Published December 2013. Originallyapproved in 1988. Last previous edition approved in 2012 as D3874 12. DOI:10.1520/D3874-13.2K. N. Mathes, Chapter 4, “Surface Failure Measurements”, EngineeringDielectrics, Vol. IIB, Electrical Properties of Solid Insulating Materials, Measure-ment Techn
14、iques, R. Bartnikas, Editor, ASTM STP 926, ASTM, Philadelphia, 1987.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM w
15、ebsite.4Available from International Electrotechnical Commission (IEC), 3 rue deVaremb, Case postale 131, CH-1211, Geneva 20, Switzerland, http:/www.iec.ch.5Available from International Organization for Standardization (ISO), 1, ch. dela Voie-Creuse, Case postale 56, CH-1211, Geneva 20, Switzerland,
16、 http:/www.iso.ch.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States14. Summary of Test Method4.1 In this test method, a rectangular bar-shaped testspecimen, with the cente
17、r portion wrapped with a coil of heaterwire, is supported horizontally at both ends. The circuit is thenenergized by applying a fixed power density to the heater wire,which rapidly heats up. The behavior of the test specimen isobserved. until one of the following happens: (a) the materialunder test
18、ignites, (b) the material under test melts, (c) 120 s ofexposure have gone by without ignition or melting. The time toignition and the time to melt through, as applicable, arerecorded.5. Significance and Use5.1 During operation of electrical equipment, includingwires, resistors, and other conductors
19、, it is possible for over-heating to occur, under certain conditions of operation, or whenmalfunctions occur. When this happens, a possible result isignition of the insulation material.5.2 This test method assesses the relative resistance ofelectrical insulating materials to ignition by the effect o
20、f hotwire sources.5.3 This test method determines the average time, inseconds, required for material specimens to ignite under thespecified conditions of test.5.4 This method is suitable to characterize materials, subjectto the appropriate limitations of an expected precision of615 %, to categorize
21、materials.5.5 In this procedure the specimens are subjected to one ormore specific sets of laboratory conditions. If different testconditions are substituted or the end-use conditions arechanged, it is not always possible by or from this test to predictchanges in the fire-test-response characteristi
22、cs measured.Therefore, the results are valid only for the fire test exposureconditions described in this procedure.6. Apparatus6.1 Heater WireThe heater wire shall be a No. 24 AWG,Nichrome (Nickel-Chrome) wire, that is iron free, with thefollowing nominal properties: a wire composition of 20 %chromi
23、um-80 % nickel, a diameter of 0.5 mm (0.020 in.), anominal cold resistance of 5.28 /m (1.61/ft), and a length-to-mass ratio of 580 m/kg (864 ft/lb).6.2 Calibrate each spool of test wire for energizedresistance, in accordance with the method outlined in AnnexA1. Such calibration is necessary due to t
24、he typical variabilityof wire lots in composition, processing, sizing, and metallurgy.6.3 Supply CircuitThe supply circuit, which is a means forelectrically energizing the heater wire, shall comply with 6.3.1 6.3.4.6.3.1 The supply circuit capacity shall be sufficient tomaintain a continuous linear
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
2000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIASTMD38742013STANDARDTESTMETHODFORIGNITIONOFMATERIALSBYHOTWIRESOURCES 利用 电热丝 测量 材料 引燃 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-432369.html