ANSI ASTM D348-2013 Standard Test Methods for Rigid Tubes Used for Electrical Insulation《电气绝缘用刚性管的试验方法》.pdf
《ANSI ASTM D348-2013 Standard Test Methods for Rigid Tubes Used for Electrical Insulation《电气绝缘用刚性管的试验方法》.pdf》由会员分享,可在线阅读,更多相关《ANSI ASTM D348-2013 Standard Test Methods for Rigid Tubes Used for Electrical Insulation《电气绝缘用刚性管的试验方法》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D348 13Standard Test Methods forRigid Tubes Used for Electrical Insulation1This standard is issued under the fixed designation D348; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number i
2、n parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1. Scope*1.1 These test methods cover the testing of rigid tubes used
3、in electrical insulation. These tubes include many types madefrom fibrous sheets of basic materials, such as cellulose, glass,or nylon, in the form of paper, woven fabrics, or mats, bondedtogether by natural or synthetic resins or by adhesives. Suchtubes include vulcanized fiber and thermosetting la
4、minates, aswell as tubes made from cast, molded, or extruded natural orsynthetic resins, with or without fillers or reinforcing materials.1.2 Tubes tested by these test methods are most commonlycircular in cross section; however, noncircular shapes are alsoin commercial use. To the extent that the i
5、ndividual methodsare compatible with a particular noncircular shape, these testmethods are applicable to these other shapes. For tests onnoncircular tubes, appropriate comments shall be included inthe test report, including details of orientation of test specimenswith respect to the cross section of
6、 the tube.1.3 The procedures appear in the following sections:Procedure SectionsASTM TestMethodReferenceCompressive Strength (Axial and Diametral) 12 to 17 E4Conditioning. 4 .Density 20 to 24 .Dielectric Strength 25 to 32 D149Dimensional Measurements 5 D668Dissipation Factor and Permittivity 33 to 3
7、5 D150Tensile Strength 6 to 11 E4Water Absorption 18 to 19 D5701.4 The values stated in inch-pound units are to be regardedas the standard. SI units in parentheses are for informationonly.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is
8、theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For a specifichazard statement, see 27.1.1.2. Referenced Documents2.1 ASTM Standards:2D149 Test Method for Dielectric Breakdow
9、n Voltage andDielectric Strength of Solid Electrical Insulating Materialsat Commercial Power FrequenciesD150 Test Methods for AC Loss Characteristics and Permit-tivity (Dielectric Constant) of Solid Electrical InsulationD570 Test Method for Water Absorption of PlasticsD668 Test Methods of Measuring
10、Dimensions of Rigid Rodsand Tubes Used for Electrical InsulationD1711 Terminology Relating to Electrical InsulationE4 Practices for Force Verification of Testing Machines3. Terminology3.1 DefinitionsFor definitions of terms used in these testmethods, refer to Terminology D1711.4. Conditioning4.1 In
11、order to eliminate the effects of previous history ofhumidity exposure and to obtain reproducible results (Note 1),the test specimens in all cases of dispute, shall be given aconditioning treatment for physical tests as follows:4.1.1 Tensile Strength, Compressive Strength (Axial andDiametral), and D
12、ensityCondition the machined specimensprior to test by drying in an air-circulating oven for 48 h at 506 3 C, followed by cooling to room temperature in adesiccator. In either case, all specimens shall be tested at roomtemperature maintained at 23 6 2 C, 50 % relative humidity.NOTE 1The following ar
13、e potential reasons to undertake conditioningof specimens: (a) for the purpose of bringing the material into equilibriumwith standard laboratory atmospheric conditions of 23 C and 50 %relative humidity; (b) simply to obtain reproducible results, irrespective ofprevious history of exposure; or (c) to
14、 subject the material to abnormalconditions of temperature or humidity in order to predict its servicebehavior.1These test methods are under the jurisdiction of ASTM Committee D09 onElectrical and Electronic Insulating Materials and are the direct responsibility ofSubcommittee D09.07 on Flexible and
15、 Rigid Insulating Materials.Current edition approved Nov. 1, 2013. Published November 2013. Originallyapproved in 1932. Last previous edition approved in 2007 as D348 07. DOI:10.1520/D0348-13.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at ser
16、viceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. Unit
17、ed States1The conditions given here to obtain reproducible results will givephysical values which could be somewhat higher or somewhat lower thanvalues under equilibrium at normal conditions, depending upon theparticular material and test. To ensure substantial equilibrium undernormal conditions of
18、humidity and temperature, however, will requirefrom 20 to 100 days or more depending upon thickness and type ofmaterial and its previous history. Consequently, conditioning for repro-ducibility must of necessity be used for general purchase specificationsand product control tests.4.1.2 Conditioning
19、of specimens for electrical tests is alsonecessary to obtain consistent results. In order to securecomparative results, specimens shall be conditioned at thesame temperature and humidity.5. Dimensional Measurements5.1 Dimensional measurements of tube shall be made inaccordance with Test Methods D668
20、.TENSILE STRENGTH6. Significance and Use6.1 Tension tests, properly interpreted, provide informationwith regard to the tensile properties of rigid tubing, whenemployed under conditions approximating those under whichthe tests are made. It is possible that the tensile strength valueswill vary with th
21、e size of the tube and with the temperature andatmospheric conditions. Tension tests provide data potentiallyuseful for research and development and for engineeringdesign, and quality control purposes.7. Apparatus7.1 Any universal testing machine is acceptable for useprovided it is accurate to 1 % o
22、f the lowest breaking load to beapplied. Jaws that tighten under load, such as wedge-grip jaws,shall be used with the specimen properly aligned.7.2 The machine shall be verified in accordance withPractices E4.8. Test Specimens8.1 The test specimens shall be as shown in Fig. 1. Thelength, L, shall be
23、 as shown in Table 1. A groove shall bemachined around the outside of the specimen at the center of itslength so that the wall section after machining shall be 60 % ofthe original nominal wall thickness. This groove shall consistof a straight section 2.25 in. (57 mm) in length with a radius of3 in.
24、(76 mm) at each end joining it to the outside diameter.Steel or brass plugs having diameters such that they will fitsnugly inside the tube, and having a length equal to the full jawlength plus 1 in. (25 mm) shall be placed in the ends of thespecimen to prevent crushing. They can be located in the tu
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIASTMD3482013STANDARDTESTMETHODSFORRIGIDTUBESUSEDFORELECTRICALINSULATION 电气 绝缘 刚性 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-432343.html