《ANSI ASTM D2152-2017 Standard Test Method for Adequacy of Fusion of Extruded Poly(Vinyl Chloride) (PVC) Pipe and Molded Fittings by Acetone Immersion.pdf》由会员分享,可在线阅读,更多相关《ANSI ASTM D2152-2017 Standard Test Method for Adequacy of Fusion of Extruded Poly(Vinyl Chloride) (PVC) Pipe and Molded Fittings by Acetone Immersion.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D2152 17 An American National StandardStandard Test Method forAdequacy of Fusion of Extruded Poly(Vinyl Chloride) (PVC)Pipe and Molded Fittings by Acetone Immersion1This standard is issued under the fixed designation D2152; the number immediately following the designation indicates the
2、year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers the determination of the ad
3、-equacy of fusion of extruded rigid poly(vinyl chloride) (PVC)pipe and molded fittings as indicated by reaction to immersionin anhydrous acetone.1.2 The values stated in inch-pound units are to be regardedas the standard except where instruments are calibrated in SIunits.1.3 This standard does not p
4、urport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety, health, and environmental practices and deter-mine the applicability of regulatory limitations prior to us-e.Specific hazards statement
5、s are given in Annex A1.1.4 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organizat
6、ion TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2D618 Practice for Conditioning Plastics for Testing3. Significance and Use3.1 This test method is applicable only for distinguishingbetween inadequately fused and adequately fused PVC. Thedifference between the
7、rmally degraded and adequately fusedPVC cannot be detected by this test method. Acetone immer-sion is not a substitute for burst, impact, or other physical orchemical tests on PVC pipe or fittings and it, therefore, shallnot be used as the only test specification for purchasing of PVCpipe and fittin
8、gs. This test only detects inadequate fusion anddoes not determine the over-all quality of the PVC pipe orfittings.3.2 This test method is useful in determining whetherinadequate fusion contributed to failure of PVC pipe or fittingsin other physical or chemical tests, or in service.3.3 This test met
9、hod is useful in evaluating the adequacy ofPVC fusion obtained in process or materials trials.3.4 This test method determines adequacy of fusion on asingle, relatively small specimen. This test method requires theuse of a hazardous reagent which must be properly handled anddisposed. Therefore, this
10、test method may not be cost-effectiveto employ as a routine quality control test.4. Apparatus4.1 ContainerEither individual, sealable containers foreach specimen or one large, airtight container capable ofholding several specimens without touching one another.4.2 Hydrometer and CylinderPrecision hyd
11、rometer,graduated in thousandths, with a minimum range of 0.780 to0.790 g/mL and a cylinder large enough to immerse thehydrometer.4.3 ThermometerASTM 12C total immersionthermometer, range from 20C to 102C accurate to 0.2C, orequivalent.5. Reagent5.1 AcetoneAmerican Chemical Society Reagent Grade,hav
12、ing a maximum density of 0.7857 g/mL at 25C.NOTE 1See AnnexA1 for the safety and health precautions to be usedwith acetone.5.2 Prior to conducting the test, check the density of theacetone with a precision hydrometer to determine its dryness.If the density of the acetone is greater than 0.934 g/mLat
13、 23C,(corresponding to approximately 2 % water by mass (see Fig.X1.1), use fresh acetone or dry the wet acetone with a dryingagent. Recheck the density of the fresh or dried acetone beforeusing.NOTE 2Wet acetone can be dried by thoroughly agitating it with at1This test method is under the jurisdicti
14、on of ASTM Committee F17 on PlasticPiping Systems and is the direct responsibility of Subcommittee F17.25 on VinylBased Pipe.Current edition approved Nov. 1, 2017. Published January 2018. Originallyapproved in 1963T. Last previous edition approved in 2013 as D2152 13. DOI:10.1520/D2152-17.2For refer
15、enced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.*A Summary of Changes section appears at the end of this standardCopyri
16、ght ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of Internation
17、al Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.1least 15 g of anhydrous calcium sulfate (CaSO4) for each gram of waterpresent.NOTE 3The presence of water in the acetone reduces its sensitivity todifferences in the degree of
18、 fusion of rigid poly(vinyl chloride) (PVC). Itis important to dry the acetone properly and conduct the test in a sealedcontainer, because acetone rapidly absorbs moisture from the atmosphere.NOTE 4Round-robin testing between four laboratories showed thattest results are not significantly altered wi
19、th up to 2 % water by weight inthe acetone.6. Sampling6.1 Specimens shall be taken from individual pipe sections,fittings, or remnant portions of pipe or fittings. Specimens shallbe taken from locations which are to be evaluated for adequacyof fusion, or immediately adjacent to them.6.2 The number o
20、f individual specimens to be tested andtheir locations shall be chosen to be representative of the pipeor fittings being evaluated for adequacy of fusion.7. Test Specimens7.1 Size of SpecimenSpecimen shall be a size that isconvenient to immerse in the test container but not less than12in. (13 mm) in
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
2000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIASTMD21522017STANDARDTESTMETHODFORADEQUACYOFFUSIONOFEXTRUDEDPOLYVINYLCHLORIDEPVCPIPEANDMOLDEDFITTINGSBYACETONEIMMERSIONPDF

链接地址:http://www.mydoc123.com/p-432268.html