1、Designation: D1385 07 (Reapproved 2013)1Standard Test Method forHydrazine in Water1This standard is issued under the fixed designation D1385; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in pa
2、rentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1NOTEThis standard was reapproved with editorial changes in January 2013.
3、1. Scope1.1 This test method covers2the colorimetric determinationof hydrazine in boiler feed waters, condensates, natural, andwell waters that have been treated with hydrazine (N2H4). Thistest method is usable in the range from 5.0 to 200 g/L (ppb)hydrazine. The range is for photometric measurement
4、s made at458 nm in 50 mm cell. Higher concentrations of hydrazine canalso be determined by taking a more diluted sample.1.2 It is the users responsibility to ensure the validity of thistest method for untested types of waters.1.3 The values stated in SI units are to be regarded asstandard. No other
5、units of measurement are included in thisstandard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of r
6、egulatory limitations prior to use. For specificprecautionary statements, see 5.3, Note 1, and Footnote 8.2. Referenced Documents2.1 ASTM Standards:3D1066 Practice for Sampling SteamD1129 Terminology Relating to WaterD1193 Specification for Reagent WaterD3370 Practices for Sampling Water from Closed
7、 ConduitsD5810 Guide for Spiking into Aqueous SamplesD5847 Practice for Writing Quality Control Specificationsfor Standard Test Methods for Water AnalysisE60 Practice for Analysis of Metals, Ores, and RelatedMaterials by SpectrophotometryE275 Practice for Describing and Measuring Performance ofUltra
8、violet and Visible Spectrophotometers3. Terminology3.1 DefinitionsFor definitions of terms used in this testmethod, refer to Terminology D1129.4. Summary of Test Method4.1 When a solution of p-dimethylaminobenzaldehyde inmethyl alcohol and hydrochloric acid is added to hydrazine indiluted hydrochlor
9、ic acid solution, a characteristic yellow colorof p-dimethylaminobenzalazine is formed. The yellow colorformed is proportional to the hydrazine present and is in goodagreement with Beers law in the range from 5.0 to 200 g/L(ppb) hydrazine.5. Significance and Use5.1 Hydrazine is a man-made chemical a
10、nd is not found innatural waters. The determination of hydrazine is usually madeon boiler feedwaters, process waters, and other waters thathave been treated with hydrazine (N2H4) for the purpose ofmaintaining residuals to prevent corrosion by dissolved oxy-gen. This reducing chemical reacts with dis
11、solved oxygen toform nitrogen and water. However, under certain conditions itcan also decompose to form ammonia and nitrogen. Hydrazineis used extensively as a preboiler treatment chemical forhigh-pressure boilers to scavenge small amounts of dissolvedoxygen that are not removed by mechanical aerati
12、on. It has theadvantage over sulfite treatment in that it does not produce anydissolved solids in the boiler water. Hydrazine is often deter-mined in concentrations below 0.1 mg/L. However, in layupsolutions for the protection of idle boilers, hydrazine may bepresent in concentrations as high as 200
13、 mg/L.1This test method is under the jurisdiction of ASTM Committee D19 on Waterand is the responsibility of Subcommittee D19.03 on Sampling Water andWater-Formed Deposits, Analysis of Water for Power Generation and Process Use,On-Line Water Analysis, and Surveillance of WaterCurrent edition approve
14、d Jan. 1, 2013. Published February 2013. Originallyapproved in 1967. Last previous edition approved in 2007 as D1385 07. DOI:10.1520/D1385-07R13E01.2For further information on this test method, the following references may be ofinterest: Watt, G. W., and Chrisp, J. D., “Spectrophotometric Method for
15、 theDetermination of Hydrazine,” Analytical Chemistry, Vol 24, No. 12, 1952, pp.20062008, and Wood, P. R., “Determination of Maleic Hydrazide Residues in Plantand Animal Tissue,” Analytical Chemistry, Vol 25, No. 12, 1953, pp. 18791883.3For referenced ASTM standards, visit the ASTM website, www.astm
16、.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States15.2 Additio
17、nally, hydrazine provides protection where re-ducing conditions are required, particularly in mixed metal-lurgy systems for the protection of the copper alloys.5.3 Hydrazine is a suspected carcinogen and a thresholdlimit value in the atmosphere of 1.0 mg/L has been set byOSHA. When in an aqueous sol
18、ution, hydrazine will oxidize tonitrogen and water in the presence of air over a relatively shortperiod of time.6. Interferences6.1 The substances normally present in industrial water donot interfere with the test; however, the hydrazine content maybe diminished by oxidizing agents, such as chlorine
19、, bromine,and iodine, collected with the sample or absorbed by it prior totesting.6.2 Colors in the prescribed wavelengths also interfere, asdo other dark colors or turbidities that cannot be overcome.6.3 Aromatic amines, such as aniline, will also interfere.7. Apparatus7.1 PhotometerAspectrophotome
20、ter suitable for measure-ments at 458 nm and capable of holding cells with a light pathof 50 mm should be used. Filter photometers and photometricpractices prescribed in this test method shall conform toPractice E60, and spectrophotometers to Practice E275.7.2 Certain photoelectric filter photometer
21、s are capable ofmeasurement at 425 nm, but not at 458 nm. Measurements maybe made at 425 nm with a reduction in sensitivity of approxi-mately 50 % of that possible at 458 nm.7.3 Instruments that read out in direct concentration can alsobe used. Manufacturers instructions should be followed.8. Reagen
22、ts8.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless otherwise indicated, it is intended thatall reagents shall conform to the specifications of the Commit-tee on Analytical Reagents of the American Chemical Society,where such specifications are available.4Other grades m
23、ay beused, provided it is first ascertained that the reagent issufficiently high in purity to permit its use without lesseningthe accuracy of the determinations.8.2 Purity of WaterUnless otherwise indicated, referencesto water shall be understood to mean reagent water conformingto the quantitative r
24、equirements of Type III reagent water inSpecification D1193.8.3 Hydrazine Solution, Stock (1.0 mL = 100 g N2H4)Dissolve 0.328 g of hydrazine dihydrochloride (HClNH2NH2HCl) in 100 mL of water and 10 mL of HCl (sp gr 1.19).Dilute with water to 1 L in a volumetric flask and mix(Warning, see Note 1).8.4
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
2000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIASTMD13852007STANDARDTESTMETHODFORHYDRAZINEINWATERPDF

链接地址:http://www.mydoc123.com/p-432241.html