ANSI ASME PTC 12.5-2000 Single Phase Heat Exchangers.pdf
《ANSI ASME PTC 12.5-2000 Single Phase Heat Exchangers.pdf》由会员分享,可在线阅读,更多相关《ANSI ASME PTC 12.5-2000 Single Phase Heat Exchangers.pdf(151页珍藏版)》请在麦多课文档分享上搜索。
1、AN AMERICAN NATIONAL STANDARD Single Phase Heat Exchangers ASME PTC 12.5-2000 Date of Issuance: December 31, 2001 This Standard will be revised when the Society approves the issuance of a new edition. There will be no addenda issued to ASME PTC 12.5-2000. Please note: ASME issues written replies to
2、inquiries concerning interpretation of technical aspects of this document. ASME is the registered trademark of The American Society of Mechanical Engineers. This code or standard was developed under procedures accredited as meeting the criteria for American National Standards. The Standards Committe
3、e that approved the code or standard was balanced to assure that individuals from competent and concerned interests have had an opportunity to participate. The proposed code or standard was made available for public review and comment that provides an opportunity for additional public input from ind
4、ustry, academia, regulatory agencies, and the public-at-large. ASME does not “approve,“ “rate,“ or “endorse“ any item, construction, proprietary device, or activity. ASME does not take any position with respect to the validity of any patent rights asserted in connection with any items mentioned in t
5、his document, and does not undertake to insure anyone utilizing a standard against liability for infringement of any applicable letters patent, nor assume any such liability. Users of a code or standard are expressly advised that determination of the validity of any such patent rights, and the risk
6、of infringement of such rights, is entirely their own responsibility. Participation by federal agency representative(s) or person(s) affiliated with industry is not to be interpre ted as government or industry endorsement of this code or standard. ASME accepts responsibility for only those interpret
7、ations of this document issued in accordance with the established ASME procedures and policies, which precludes the issuance of interpretations by individuals. No part of this document may be reproduced in any form, in an electronic retrieval system or otherwise, without the prior written permission
8、 of the publisher. The American Society of Mechanical Engineers Three Park Avenue, New York, NY 10016-5990 Copyright 2001 by THE AMERICAN SOCIETY OF MECHANICAL ENGINEERS All Rights Reserved Printed in U.S.A. FOREWORD Performance tests of industrial heat exchangers are often conducted to compare test
9、 results with manufacturers rating data, to evaluate the cause(s) of degradation, to verify regulatory compliance, or to assess process improvements. All tests have associated costs. Those costs can be great if the test results are inconclusive. Historically, testing heat exchanger performance in op
10、erating processes was not conducted according to standard, acceptable methods; therefore, the results were inconsistent. Many of the unacceptable results have been attributed to small deviations in test conditions and measurement prac tices. In other cases, analysis of the data did not consider all
11、factors which affect performance. As industry implements improvements to reduce costs and increase output, performance margins of process streams tend to be reduced. The need for accurate performance test methods is increasing to meet the commercial demand. A single consistent test philosophy and me
12、thodology including measurement and analysis techniques for delivery of accurate and repeatable heat exchanger test data would provide a foundation to assess performance. Such a test standard has wide applicability in the power, food-processing, chemical and petroleum industries, among others. It wa
13、s with the intent of satisfying these industry needs that the Board on Performance Test Codes (BPTC) authorized the formation of the PTC 12.5 Committee to explore the development of the present Code. The PTC 12.5 Committee began its deliberations late in 1994. An early version of the draft code was
14、subjected to a thorough review by industry, including members of the BPTC. Comments were incorporated in the version which was approved by the Committee on 11 August 1999. PTC 12.5-2000 on Single Phase Heat Exchangers was then approved as a Standard practice of the Society by action of the Board on
15、Performance Test Codes on 8 May 2000. It was approved as an American National Standard by the ANSI Board of Standards Review on September 26, 2000. (Revised 26 September 2000) iii NOTICE All Performance Test Codes MUST adhere to the requirements of PTC 1, GENERAL INSTRUCTIONS. The following informat
16、ion is based on that document and is included here for emphasis and for the convenience of the user of this Code. It is expected that the Code user is fully cognizant of Parts I and Ill of PTC 1 and has read them prior to applying this Code. ASME Performance Test Codes provide test procedures which
17、yield results of the highest level of accuracy consistent with the best engineering knowledge and practice currently available. They were developed by balanced committees representing all concerned interests. They specify procedures, instrumentation, equipment operating requirements, calculation met
18、hods, and uncertainty analysis. When tests are run in accordance with this Code, the test results themselves, without adjustment for uncertainty, yield the best available indication of the actual performance of the tested equipment. ASME Performance Test Codes do not specify means to compare those r
19、esults to contractual guarantees. Therefore, it is recommended that the parties to a commercial test agree before starting the test and preferably before signing the contract on the method to be used for comparing the test results to the contractual guarantees. It is beyond the scope of any Code to
20、determine or interpret how such comparisons shall be made. Approved by Letter Ballot #95-1 and BPTC Administrative Meeting of March 13-14, 1995. iv PERSONNEL OF PERFORMANCE TEST CODE COMMITTEE NO. 12.5 ON SINGLE PHASE HEAT EXCHANGERS OFFICERS Thomas G. Lestina, Chair Benjamin H. Scott, Vice Chair Ge
21、orge Osolsobe, Secretary COMMITIEE PERSONNEL Fernando J. Aguirre, Heat Transfer Research, Inc. Kenneth J. Bell, Oklahoma State University Charles F. Bowman, Chuck Bowman Associates William H. Closser, Jr., C (b) Plate-frame; (c) Plate-fin; (d) Tube-in-plate fin. 3 Single-phase fluid streams, includi
22、ng liquid-to-liq uid, gas-to-liquid, and gas-to-gas are included. Ex cluded from this Code are heat exchangers used in condensation, vaporization, fired, direct contact, non-newtonian fluid, and more than two-fluid appli cations. 1.3 EXPECTED UNCERTAINTY The values of the overall uncertainty of perf
23、orm ance parameters determined in accordance with this Code are expected to lie within the band described by the overall uncertainty interval stated below. Performance Parameter Note (1 ) Overall Heat Transfer Coefficient, U* Heat Transfer Rate, Q* Nozzle-to-Nozzle Pressure Loss, .tlP,.,n* NOTES: (1
24、) At reference conditions. (2 Based on 95% confidence. Expected Uncertainty Note (2) 3-10% 3-10% 3-12% This page intentionally left blank.SINGLE PHASE HEAT EXCHANGERS ASME PTC 12.5-2000 SECTION 2 - DEFINITIONS AND DESCRIPTION OF TERMS 2.1 TERMS In this Section, only those terms are defined which are
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIASMEPTC1252000SINGLEPHASEHEATEXCHANGERSPDF

链接地址:http://www.mydoc123.com/p-432040.html