ANSI ASA S1.15 PART 2-2005 American National Standard Measurement Microphones C Part 2 Primary Method for Pressure Calibration of Laboratory Standard Microphones by the Reciprocity.pdf
《ANSI ASA S1.15 PART 2-2005 American National Standard Measurement Microphones C Part 2 Primary Method for Pressure Calibration of Laboratory Standard Microphones by the Reciprocity.pdf》由会员分享,可在线阅读,更多相关《ANSI ASA S1.15 PART 2-2005 American National Standard Measurement Microphones C Part 2 Primary Method for Pressure Calibration of Laboratory Standard Microphones by the Reciprocity.pdf(62页珍藏版)》请在麦多课文档分享上搜索。
1、 ANSI S1.15-2005/Part 2 AMERICAN NATIONAL STANDARD Measurement Microphones Part 2: Primary Method for Pressure Calibration of Laboratory Standard Microphones by the Reciprocity Technique Accredited Standards Committee S1, Acoustics Standards Secretariat Acoustical Society of America 35 Pinelawn Road
2、, Suite 114 E Melville, NY 11747-3177ANSI S1.15-2005/Part 2 Reaffirmed by ANSI June 2, 2010 Reaffirmed by ANSI May 13, 2015 The American National Standards Institute, Inc. (ANSI) is the national coordinator of voluntary standards development and the clearinghouse in the U.S.A. for information on nat
3、ional and international standards. The Acoustical Society of America (ASA) is an organization of scientists and engineers formed in 1929 to increase and diffuse the knowledge of acoustics and to promote its practical applications. ANSI S1.15- 2005 /Part 2 (Replaces ANSI S1.10-1966) AMERICAN NATIONAL
4、 STANDARD Measurement Microphones Part 2: Primary Method for Pressure Calibration of Laboratory Standard Microphones by the Reciprocity Technique Secretariat Acoustical Society of America Approved by: American National Standards Institute, Inc. 9 March 2005 Abstract This Standard specifies a primary
5、 method for the calibration of microphones by the reciprocity technique. The specifications are intended to ensure that primary calibration with the reciprocity technique can attain the highest accuracy. The technical requirements of this American National Standard is identical to International Stan
6、dard IEC 61094-2: 1992, “Measurement microphones - Part 2: Primary method for pressure calibration of laboratory standard microphones by the reciprocity technique“. Various improvements have been made to include recent technical information. 2 AMERICAN NATIONAL STANDARDS ON ACOUSTICS The Acoustical
7、Society of America (ASA) provides the Secretariat for Accredited Standards Committees S1 on Acoustics, S2 on Mechanical Vibration and Shock, S3 on Bioacoustics, and S12 on Noise. These committees have wide representation from the technical community (manufacturers, consumers, trade associations, org
8、anizations with a general interest, and government representatives). The standards are published by the Acoustical Society of America as American National Standards after approval by their respective Standards Committees and the American National Standards Institute. These standards are developed an
9、d published as a public service to provide standards useful to the public, industry, and consumers, and to Federal, State, and local governments. Each of the accredited Standards Committees operating in accordance with procedures approved by American National Standards Institute (ANSI) is responsibl
10、e for developing, voting upon, and maintaining or revising its own Standards. The ASA Standards Secretariat administers Committee organization and activity and provides liaison between the Accredited Standards Committees and ANSI. After the Standards have been produced and adopted by the Accredited
11、Standards Committees, and approved as American National Standards by ANSI, the ASA Standards Secretariat arranges for their publication and distribution. An American National Standard implies a consensus of those substantially concerned with its scope and provisions. Consensus is established when, i
12、n the judgment of the ANSI Board of Standards Review, substantial agreement has been reached by directly and materially affected interests. Substantial agreement means much more than a simple majority, but not necessarily unanimity. Consensus requires that all views and objections be considered and
13、that a concerted effort be made towards their resolution. The use of an American National Standard is completely voluntary. Their existence does not in any respect preclude anyone, whether he or she has approved the Standards or not, from manufacturing, marketing, purchasing, or using products, proc
14、esses, or procedures not conforming to the Standards. NOTICE: This American National Standard may be revised or withdrawn at any time. The procedures of the American National Standards Institute require that action be taken periodically to reaffirm, revise, or withdraw this Standard. Acoustical Soci
15、ety of America ASA Secretariat 35 Pinelawn Road, Suite 114E Melville, New York 11747-3177 Telephone: 1 (631) 390-0215 Fax: 1 (631) 390-0217 E-mail: asastdsaip.org 2005 by Acoustical Society of America. This standard may not be reproduced in whole or in part in any form for sale, promotion, or any co
16、mmercial purpose, or any purpose not falling within the provisions of the U.S. Copyright Act of 1976, without prior written permission of the publisher. For permission, address a request to the Standards Secretariat of the Acoustical Society of America.iContents 1 Scope 1 2 Normative references 1 3
17、Definitions 1 4 Reference environmental conditions. 2 5 Principles of pressure calibration by reciprocity 3 5.1 General principle 3 5.2 Basic expressions 3 5.3 Insert voltage technique. 4 5.4 Evaluation of the acoustic transfer impedance 5 5.5 Heat-conduction correction 7 5.6 Capillary tube correcti
18、on 7 5.7 Final expressions for the pressure sensitivity 8 6 Factors influencing the pressure sensitivity 8 6.1 General 8 6.2 Polarizing voltage. 9 6.3 Ground shield reference configuration. 9 6.4 Pressure distribution over the diaphragm 9 6.5 Dependence on environmental conditions. 10 7 Calibration
19、uncertainty components 10 7.1 General 10 7.2 Electrical transfer impedance. 11 7.3 Acoustical transfer impedance. 11 7.4 Polarizing voltage. 13 7.5 Uncertainty on pressure sensitivity level 13 Annex A (normative) Heat conduction in a closed cavity . 17 A.1 14 A.2 Bibliography for Annex A . 15 Annex
20、B (normative) Acoustic impedance of a capillary tube 17 B.1 Determination by the transmission line theory. 17 B.2 Bibliography for Annex B . 18 Annex C (informative) Examples of cylindrical couplers for calibration of microphones 21 ii C.1 General 21 C.2 Plane-wave couplers 21 C.3 Large-volume coupl
21、ers 23 C.4 Bibliography for Annex C . 24 Annex D (informative) Environmental influence on the sensitivity of microphones . 25 D.1 General 25 D.2 Dependence on static pressure . 25 D.3 Microphone sensitivity pressure correction 26 D.4 Dependence on temperature . 28 D.5 Bibliography for Annex D . 30 A
22、nnex E (informative) Methods for determining microphone parameters 31 E.1 Introduction 31 E.2 Front cavity depth 31 E.3 Front cavity volume and equivalent volume. 31 E.4 Acoustic impedance of the microphone. 32 Annex F (informative) Physical properties of air 33 F.1 Properties. 33 F.2 Nomenclature:
23、33 F.3 Density of humid air . 34 F.4 Speed of sound in air. 35 F.5 Ratio of specific heats of air. 37 F.6 Viscosity and thermal diffusivity of air for capillary correction . 37 F.7 Bibliography for Annex F 39 Annex G (informative) A numerical example for the calculation of estimated expanded uncerta
24、inty41 Bibliography 43 Tables Table A.1 Values for Ev. 16 Table B.1a Real part of Za,C in gigapascal-second per cubic metre (GPag152sg152m-3). 19 Table B.1b Imaginary part of Za,Cin gigapascal-second per cubic metre (GPag152sg152m-3) . 20 Table C.1 Nominal dimensions for plane-wave couplers . 22 Tab
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIASAS115PART22005AMERICANNATIONALSTANDARDMEASUREMENTMICROPHONESCPART2PRIMARYMETHODFORPRESSURECALIBRATIONOFLABORATORYSTANDARDMICROPHONESBYTHERECIPROCITYPDF

链接地址:http://www.mydoc123.com/p-431097.html