ANSI AAMI 23500-2014 Guidance for the preparation and quality management of fluids for hemodialysis and related therapies.pdf
《ANSI AAMI 23500-2014 Guidance for the preparation and quality management of fluids for hemodialysis and related therapies.pdf》由会员分享,可在线阅读,更多相关《ANSI AAMI 23500-2014 Guidance for the preparation and quality management of fluids for hemodialysis and related therapies.pdf(100页珍藏版)》请在麦多课文档分享上搜索。
1、ANSI/AAMI 23500:2014Guidance for the preparation and quality management of fluids for hemodialysis and related therapiesAmerican National StandardAmerican National Standard ANSI/AAMI 23500:2014 Guidance for the preparation and quality management of fluids for hemodialysis and related therapies Appro
2、ved 21 July 2014 by Association for the Advancement of Medical Instrumentation Approved 15 August 2014 by American National Standards Institute, Inc. Abstract: Addresses the users responsibility for the dialysis fluid once the equipment used in its preparation has been delivered and installed. Inclu
3、des dialysis water used for the preparation of dialysis fluid and substitution fluid, dialysis water used for the preparation of concentrates at the users facility, as well as concentrates and the final dialysis fluid and substitution fluid. Keywords: concentrate, microbiological, monitoring, qualit
4、y, system, validation, water AAMI Standard This Association for the Advancement of Medical Instrumentation (AAMI) standard implies a consensus of those substantially concerned with its scope and provisions. The existence of an AAMI standard does not in any respect preclude anyone, whether they have
5、approved the standard or not, from manufacturing, marketing, purchasing, or using products, processes, or procedures not conforming to the standard. AAMI standards are subject to periodic review, and users are cautioned to obtain the latest editions. CAUTION NOTICE: This AAMI standard may be revised
6、 or withdrawn at any time. AAMI procedures require that action be taken to reaffirm, revise, or withdraw this standard no later than five years from the date of publication. Interested parties may obtain current information on all AAMI standards by calling or writing AAMI, or by visiting the AAMI we
7、bsite at www.aami.org. All AAMI standards, recommended practices, technical information reports, and other types of technical documents developed by AAMI are voluntary, and their application is solely within the discretion and professional judgment of the user of the document. Occasionally, voluntar
8、y technical documents are adopted by government regulatory agencies or procurement authorities, in which case the adopting agency is responsible for enforcement of its rules and regulations. Published by Association for the Advancement of Medical Instrumentation 4301 N. Fairfax Drive, Suite 301 Arli
9、ngton, VA 22203-1633 www.aami.org 2014 by the Association for the Advancement of Medical Instrumentation All Rights Reserved Publication, reproduction, photocopying, storage, or transmission, electronically or otherwise, of all or any part of this document without the prior written permission of the
10、 Association for the Advancement of Medical Instrumentation is strictly prohibited by law. It is illegal under federal law (17 U.S.C. 101, et seq.) to make copies of all or any part of this document (whether internally or externally) without the prior written permission of the Association for the Ad
11、vancement of Medical Instrumentation. Violators risk legal action, including civil and criminal penalties, and damages of $100,000 per offense. For permission regarding the use of all or any part of this document, complete the reprint request form at www.aami.org or contact AAMI at 4301 N. Fairfax D
12、rive, Suite 301, Arlington, VA 22203. Phone: (703) 525-4890; Fax: (703) 525-1067. Printed in the United States of America ISBN 1-57020-550-7 Contents PageGlossary of equivalent standards . v US deviation to ISO 23500:2014 vii Introduction . viii1 Scope 1 1.1 General . 1 1.2 Inclusions . 1 1.3 Exclus
13、ions 1 2 Normative references 1 3 Terms and definitions 2 4 Summary of quality requirements of ISO 13958, ISO 13959 and ISO 11663 . 9 4.1 Dialysis water . 10 4.2 Requirements for concentrate 12 4.3 Requirements for dialysis fluid 12 4.4 Record retention 13 5 Critical aspects of system design 13 5.1
14、Technical aspects 14 5.2 Microbiological aspects 14 6 Validation of system performance . 15 6.1 Validation plan . 15 6.2 Installation and operational qualification 16 6.3 Performance qualification . 17 6.4 Routine monitoring and revalidation . 17 7 Quality management 18 7.1 General . 18 7.2 Monitori
15、ng of fluid quality . 18 7.3 Monitoring of water treatment equipment . 19 7.4 Monitoring of dialysis water storage and distribution 23 7.5 Monitoring of concentrate preparation 24 7.6 Monitoring of concentrate distribution 25 7.7 Monitoring of dialysis fluid proportioning . 25 8 Strategies for micro
16、biological control . 25 8.1 General . 25 8.2 Disinfection 26 8.3 Microbiological monitoring methods . 28 9 Environment . 31 10 Personnel . 31 Annex A (informative) Rationale for the development and provisions of this International Standard . 32 Annex B (informative) Equipment . 36 Annex C (informati
17、ve) Monitoring guidelines for water treatment equipment, distribution systems, and dialysis fluid . 55 Annex D (informative) Strategies for microbiological control 62 Annex E (informative) Validation . 67 Annex F (informative) Special considerations for home hemodialysis . 70 Annex G (informative) S
18、pecial considerations for acute hemodialysis . 76 Bibliography . 81 Glossary of equivalent standards International Standards adopted in the United States may include normative references to other International Standards. AAMI maintains a current list of each International Standard that has been adop
19、ted by AAMI (and ANSI). Available on the AAMI website at the address below, this list gives the corresponding U.S. designation and level of equivalency to the International Standard. www.aami.org/standards/glossary.pdf 2014 Association for the Advancement of Medical Instrumentation ANSI/AAMI 23500:2
20、014 v Committee representationAssociation for the Advancement of Medical Instrumentation AAMI Renal Disease and Detoxification Committee This American National Standard was developed by the AAMI Renal Disease and Detoxification Committee. Approval of the American National Standard does not necessari
21、ly imply that all committee members voted for its approval. At the time this document was published, the AAMI Renal Disease and Detoxification Committee had the following members: Chairs: Conor Curtin David Roer, MD, FACP, FASN, FASH Members: G Steven Acres, MD, Carolina Regional Nephrology Associat
22、es James Weldon Baker, AmeriWater Alex Barten, Baxter Healthcare Corporation Christian Gert Bluchel, AWAK Technologies Pte Ltd. Karla S. Byrne, Rockwell Medical Inc Danilo B. Concepcion, CBNT, CCHT-A, St Joseph Hospital Renal Center Deborah A. Cote, MSN ,RN, CNN, National Renal Administrators Associ
23、ation Conor Curtin, Fresenius Medical Care North America Jim Curtis, Portland, OR R. Barry Deeter, RN MSN, University of Utah Dialysis Program Martin T. Gerber, Medtronic Inc. Gema Gonzalez, FDA/CDRH/ODE Elizabeth Howard, DaVita, Inc. Byron L. Jacobs, CBET, Sanford USD Medical Center Judith Kari, He
24、alth Care Financing Administration Kendall Larson, Mar Cor Purification Nathan W. Levin, MD, Renal Research Institute LLC Jo Ann Maltais, PhD, Maltais Consulting Duane Martz, B Braun of America, Inc. Lane McCarthy, CCHT, Hortense they are not intended as detailed design standards. Requirements for w
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIAAMI235002014GUIDANCEFORTHEPREPARATIONANDQUALITYMANAGEMENTOFFLUIDSFORHEMODIALYSISANDRELATEDTHERAPIESPDF

链接地址:http://www.mydoc123.com/p-430323.html