AIR FORCE MIL-DTL-25666 7-1995 CONVERTER LIQUID OXYGEN TYPE ME-3《ME-3型液氧转换器》.pdf
《AIR FORCE MIL-DTL-25666 7-1995 CONVERTER LIQUID OXYGEN TYPE ME-3《ME-3型液氧转换器》.pdf》由会员分享,可在线阅读,更多相关《AIR FORCE MIL-DTL-25666 7-1995 CONVERTER LIQUID OXYGEN TYPE ME-3《ME-3型液氧转换器》.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、I MIL-DTL-25666/7 (USAF) 15 September 1995 SUPERSEDING O1 April 1983 MIL-C-25674D (USAF) DETAIL SPECIFICATION CONVERTER LIQUID OXYGEN TYPE ME-3 This specification is approved for use by the Department of the Air Force and is available for use by ali Departments and Agencies of the Department of Defe
2、nse. 1. SCOPE 1.1 Scoue. This specification covers one type of liquid oxygen converter with a capacitance gauging element. It provides storage and pressurization of 25 liters of liquid oxygen to 300 pounds per square inch gauge (psig), nominal pressure and does not include warming coils. The convert
3、er is designated type ME-3. 2. APPLICABLE DOCUMENTS 2.1 General. The documents listed in this section are needed to meet the requirements specified in sections 3, 4, and 5 of this specification. This section does not include documents cited in other sections of this specification or recommended for
4、additional information or as examples. While evew effort has been made to ensure the completeness of this list, document users are cautioned that they must meet all specified requirements documents cited in sections 3,4, and 5 of this specification, whether or not they are listed. 2.2 Government doc
5、uments. 2.2.1 d tandards. The following specifications and standards form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those listed in the issue of the Department of Defense index for Specifications and Standards (DODISS) and s
6、upplement thereto, cited in the solicitation (see 6.2). SPECIFICATIONS DEPARTMENT OF DEFENSE MIL-V-9050 MIL-C-25516 MIL-DTL-25666 Valve, Oxygen, Aircraft, Pressure Relief Connectors, Electrical, Miniature, Coaxial, Environmental Resistant Type, Converter, Liquid Oxygen, Capacitance Type Gauging, Gen
7、eral Specification General Specification for For Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be of use improving this document should be addressed to: OC-ALCRICLA, 3001 Staff Eve, Tinker AFB, OK 73 145- 5990 by using the Standardization Document Impro
8、vement Proposal D Form 1426) appearing at the end of this document or by letter. AMSC NIA FSC 1660 DISTFUBUT ION STATEMENT A. Approved for public release; distribution is unlimited. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,- flIL-DTL-Z5bbb/7 U
9、999Ob 2005343 552 m MIL-DTL-25666/7 STANDARDS DEPARTMENT OF DEFENSE MIL-STD- 129 Marking for Shipment and Storage (nless otherwise indicated, copies of federal and military specifications, and standards are available from the Standardization Documents Order Desk, Building 4D, 700 Robbins Ave, Philad
10、elphia, PA 191 11-5094) 2.3 Order of Precedence. In the event of a conflict between the text of this document and the references cited herein, the text of this documents takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has be
11、en obtained. 3. REQUIREMENTS 3.1 Oualification. Converters fiunished under this specification shall be products which are qualified for listing on the applicable qualified products list at the time set for opening of bids (See 4.2 and 6.3). 3.2 Besign. The converter shall conform to the dimensions a
12、nd general design shown on figures 1 and 2. The converter shall have a minimum capacity of 25 liters of liquid oxygen measured at 1 atmosphere plus at least 3 percent of this volume to allow for the change in liquid density at the operating pressure. The converter shall be designed for an operating
13、pressure of 300 psig. 3.2.1 Schematic Diagam. The converter shall be designed in accordance with the schematic diagram shown on figure 3. 3.2.2 Design streneth. The converter shall be designed to satis the dynamic force requirements specified in MIL-DTL-25666. When subjected to the acceleration test
14、, the following exceptions to the values for G levels shall apply: Vertical (down) 9G Vertical (up) 3G Lateral 4G 3.2.3 Relief valves. The relief valves shall conform to the performance requirements of types III and IV of MIL-V-9050 and shall be of such size and shape to fit the overall dimensions s
15、pecified for the converter. 3.2.4 Weight. The weight of the complete converter shall not exceed 38 pounds. 3 2.5 Marking of ports. Ports shall be marked as shown on figure 2. 3.2.6 Overpressure safety device. Safety discs or other secondary overpressure devices, as specified in MIL- DTL-25666 shall
16、not be required for this converter. The design of this converter incorporates two pressure relief valves. 3.3 Perform ance. 3.3.1 Final assemblv pressure. The pressure used for the final assembly pressure test shall be 320 psig. 3.3.2 Filling. Filling time shall not exceed 10 minutes when the conver
17、ter is tested as specified. 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,- MIL-DTL-25666/7 I 9999906 2005744 499 MIL-DTL-25666/7 3.3.3 Evaporation loss. 3.3.3.1 Vent condition. The evaporation loss of the essentially full converter in the vent co
18、ndition shall not exceed 4 pounds of oxygen when tested as specified in MIL-DTL-25666. 3.3.3.2 Buildup cond ition. The evaporation loss of the essentially full converter in the buildup condition shall not exceed 4 pounds of oxygen when tested as specified in MIL-DTL-25666. 3.3.4 BuilduD time. Buildu
19、p time shall not exceed 10 minutes when the converter is tested as specified in MIL-DTL-25666. 3.3.5 Capacitance. The capacitance of the sensing element of the empty converter shall be 303.5 k2.5 picofarad (pf) when tested as specified in MIL-DIL-25666. 3.3.6 Inner vessel pressure. 3.3.6.1 Inner ves
20、sel. The inner vessel shall meet the performance requirements for the inner vessel pressure test specified in MIL-DTL-25666 when subjected to a pressure of 500 psig. 3.3.6.2 Permanent volumetric expansion. The converter shall meet the performance requirements for permanent volumetric expansion as sp
21、ecified in MIL-DTL-25666 when subjected to a pneumatic or hydrostatic pressure of 500 psig . 3 3.7 Delivery rate. 3.3.7.1 Constant flow. The converter shall deliver a flow of gaseous oxygen up to 150 liters per minute for not less than 2 hours with the operating pressure remaining between 295 and 3
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AIRFORCEMILDTL2566671995CONVERTERLIQUIDOXYGENTYPEME3ME3 液氧 转换器 PDF

链接地址:http://www.mydoc123.com/p-427720.html