AIR FORCE MIL-DTL-25666 6-1995 CONVERTER LIQUID OXYGEN GCU-20 A《GCU-20 A型液氧转换器》.pdf
《AIR FORCE MIL-DTL-25666 6-1995 CONVERTER LIQUID OXYGEN GCU-20 A《GCU-20 A型液氧转换器》.pdf》由会员分享,可在线阅读,更多相关《AIR FORCE MIL-DTL-25666 6-1995 CONVERTER LIQUID OXYGEN GCU-20 A《GCU-20 A型液氧转换器》.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、 MIL-DTL-25bbb/b 999990b 2006323 Lbb I INCH-POUNDI MIL-DTL-2566616 (USAF) 15 September 1995 SUPERSEDMG 04 December 1980 MIL-C-27652D (USAF) DETAIL SPECIFICATION CONVERTER, LIQUID OXYGEN GCU-20/A This specification is approved for use by the Department of the Air Force and is available for use by all
2、 Departments and Agencies of the Department of Defense. I. SCOPE 1.1 Scope. This specification covers one type of converter. It provides storage and pressurization of 75 liters of liquid oxygen to 300 pounds per square inch gauge (psig), nominal pressure and does not include warming coils. The conve
3、rter is designated GCU-20/A. 2. APPLICABLE DOCUMENTS 2.1 General. The documents listed in this section are needed to meet the requirements specified in sections 3, 4, and 5 of this specification. This section does not include documents cited in other sections of this specification or recommended for
4、 additional information or as examples. While every effort has been made to ensure the completeness of this list, document users are cautioned that they must meet all specified requirements documents cited in sections 3,4, and 5 of this specification, whether or not they are listed. 2.2 Government d
5、ocuments. 2.2.1 Spec ifications. and standards. The following specifications and standards form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those listed in the issue of the Department of Defense Index for Specifications and St
6、andards (DODISS) and supplement thereto, cited in the solicitation (see 6.2). SPECIFICATIONS DEPARTMENT OF DEFENSE MIL-V-9050 MIL-C-25516 MIL-DTL-25666 Valves, Oxygen, Pressure Relief, Aircraft Connectors, Electrical, Miniature, Coaxial, Environment Resistant Type, Converters, Liquid Oxygen, Capacit
7、ance Type Gauging, General Specification General Specification for For Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be of use in improving this document should be addressed to: OC-ALUTICLA, 3001 Staff Drive, Tinker AFB, OK 73 145- 3037 by using the sel
8、f-addressed Standardization Document Improvement Proposal (DD Form 1426) appearing at the end of this document or by letter. AMSC NIA FSC 1660 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. Provided by IHSNot for ResaleNo reproduction or networking permitted withou
9、t license from IHS-,-,- MIL-DTL-25bbb/b = 999990b 2Oi3bL24 OT2 m MIL-DTL-25666/6 STANDARD DEPARTMENT OF DEFENSE MIL-STD- 129 Marking for Shipment and Storage (Unless otherwise indicated, copies of the above specifications, and stanL-rds are available from the Standardization Documents Order Desk, Bu
10、ilding 4D, 700 Robbins Ave, Philadelphia, PA 191 1 1-5094) 2.3 Order of Precedence. In the event of a conflict between the text of this document and the references cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations
11、unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 qualification. The connectors furnished under this specification shall be products which are authorized by the qualifying activity for listing on the applicable qualified products list at the time set for opening of bids (see 4.2 and
12、 6.3). 3.2 Design and construction. The converter shall conform to figures 1 through 3. The converter shall have an operating pressure of 300 pounds per square inch gage (psig) and a minimum capacity of 75 liters of liquid oxygen measured at 1 atmosphere plus at least 3 percent of this volume to all
13、ow for the change in liquid density at the operating pressure, 3.2.1 Strength. The filled converter shall be designed to withstand the dynamic loads that are imposed by the following accelerations: Vertical down 9G Verticalup 3G Lateral 4G 3.2.2 Marking of ports. The ports shall be marked as indicat
14、ed in figure 2 3.2.3 Pressure relief valves. The pressure relief valves shall conform to types 111 and IV of MIL-V-9050 and shall be of such size and shape to fit the over-all dimensions specified for the converter. 3.2.4 Weight. The weight of the converter shall not exceed 80 pounds. 3.3 Performanc
15、e. 3.3.1 Final assembly pressure. The final assembly pressure of the converter shall be 320 psig. 3.3.2 Filling time. The time required to fill the converter shall not exceed 30 minutes. 3.3.3 Evaporation loss. 3.3.3.1 Vented condition. The evaporation loss of the essentially full converter in the v
16、ent condition shall not exceed 9 pounds. 3.3.3.2 Buildup condition. The evaporation loss of the essentially full converter in the buildup condition shall not exceed 5 pounds. 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MlL-DTL-25666/6 3.3.4 Bui
17、ldup time. The time required for the converter to reach its operating pressure immediately after it has been filled shall not exceed 15 minutes. 3.3.5 Capacitance. The capacitance of the sensing element, after it is installed in the empty converter, shall be 9 i 0.0 i7.5 picofarad (pf). 3.3.6 Inner
18、vessel pressure. 3.3.6.1 Inner vessel. The inner vessel shall meet the performance requirements for the inner vessel pressure test specified in MIL-DTL-25666 when subjected to a pressure of 500 psig. 3.3.6.2 Permanent volumetric expansion. The converter shall meet the performance requirements for pe
19、rmanent volumetric expansion as specified in MIL-DTL-25666 when subjected to a pneumatic or hydrostatic pressure of 500 psig . 3 3.7 Delivery rate. 3.3.7.1 Constant flow. The converter shall deliver a flow of gaseous oxygen up to 400 liters per minute for not less than 2.25 hours with the operating
20、pressure remaining between 295 and 3 15 psig after the first 15 minutes of flow. An intermittent increase or decrease of pressure by an additional 5 psig is allowable, but these variations shall not exceed a 2-minute interval for any one pressure cycle. The flow at the specified rate shall be initia
21、ted within 10 minutes after the converter has reached the operating pressure. The full test procedure is specified in MIL-DTL- 25666. 3.3.8 Calibration. The capacitance sensing element shall have characteristics that provide for a linear relationship between electrical capacitance and volume of liqu
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AIRFORCEMILDTL2566661995CONVERTERLIQUIDOXYGENGCU20AGCU20A 液氧 转换器 PDF

链接地址:http://www.mydoc123.com/p-427717.html