AIR FORCE A-A-59821-2009 DUMMY LOAD ELECTRIC《电仿真负载》.pdf
《AIR FORCE A-A-59821-2009 DUMMY LOAD ELECTRIC《电仿真负载》.pdf》由会员分享,可在线阅读,更多相关《AIR FORCE A-A-59821-2009 DUMMY LOAD ELECTRIC《电仿真负载》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Beneficial comments, recommendations, additions, deletions, clarifications, etc. and any other data that may improve this document should be sent to: WR-ALC/742 CBSG, 460 Richard Ray BLVD, Ste 200, Robins AFB, GA 31098-1611. Since contact information can change, you may want to verify the currency o
2、f this address information using the ASSIST Online database at http:/assist.daps.dla.mil . FSC 6625 A-A-59821 17 February 2009 COMMERICIAL ITEM DESCRIPTION DUMMY LOAD, ELECTRIC 1. SCOPE. This Commercial Item Description (CID) describes an Electric Dummy Load. The Dummy Load is used to replace the ou
3、tput load, such as an antenna, for a Radio Frequency (RF) signal source, for testing purposes. This CID is meant as a minimum requirement for the equipment in which only those manufacturers that meet or surpass the following requirements are qualified per this CID. 2. CLASSIFICATION. Equipment cover
4、ed by this CID shall be commercially available equipment and may be modified to the extent necessary to meet this description. The equipment shall be Class 3 in accordance with MIL-PRF-28800, except as specified herein. 3. SALIENT CHARACTERISTICS. The equipment shall be capable of operation within t
5、he accuracies, limits, and specifications herein. 3.1 Safety and Environmental. The equipment shall meet all safety and environmental requirements as specified in MIL-PRF-28800 for the classification as stated herein except as specified herein. 3.2 Temperature Operating. The equipment shall conform
6、to its specified performance and accuracy while being operated in an ambient temperature range of 40C to +45C. 3.2.1 Temperature Non-operating. The equipment shall conform to its specified performance and accuracy after being stored in an environment in the temperature range of 40C to +45C. 3.3 Reli
7、ability. The design of the equipment shall be such that under normal use and operation the equipment does not fail within 1500 hours of operation with a statistical certainty of 95%. 3.4 Calibration and Maintenance Adjustments. The design of the system shall provide for readily accessible calibratio
8、n adjustments and maintenance adjustments. The calibration adjustments, wherever possible, shall be accessible without removal of the equipment case or modules. The calibration interval shall be a period of one year or greater based on an operating time of 2000 hours. No special tools shall be requi
9、red for alignment or adjustment except those furnished with the equipment. 3.5 Performance Requirements. The equipment shall meet all requirements specified herein, under all combinations of input power conditions, output signal conditions and operating service condition as specified in MIL-PRF-2880
10、0 for the class specified herein. 3.5.1 Impedance. The equipment shall have an impedance of fifty ohms for the frequency range and Voltage Standing Wave Ratio (VSWR) characteristics specified herein. 3.5.2 Frequency Range and VSWR. The equipment shall operate from DC to 1 GHz with a VSWR of 1.1 maxi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
2000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AIRFORCEAA598212009DUMMYLOADELECTRIC 仿真 负载 PDF

链接地址:http://www.mydoc123.com/p-427181.html