1、 INCH-POUNDA-A-59620 September 1, 2004 COMMERIAL ITEM DESCRIPTION TEST STAND, AIRCRAFT GENERATOR CONSTANT SPEED DRIVE (CSD) UNITS The General Services Administration has authorized the use of this commercial item description, for all federal agencies. 1. SCOPE. 1.1 Scope. This is a Performance Purch
2、ase Description (PPD) for a CSD Test Stand (TS), for field testing multi-aircraft Integrated Drive Generators (IDG), Constant Speed Drives (CSD), and their associated generators. 2. SALIENT CHARACTERISTICS. 2.1 Equipment. A current and complete Test Stand (TS) shall be provided. The proposed TS shal
3、l be of modular design and shall include all items and /or accessories required for testing all the identified IDGs and CSDs (see Table 3-2 Page 2). When actual accuracys or specified ranges are not directly specified, the “best commercial practice” shall be proposed. 2.2 Function. Field level test
4、stand is used to test aircraft Intergraded Drive Generators (IDG), the IDG consists of the Constant Speed Drives (CSD) Units and its associated Generator. The test stand shall accept and successfully operate all the IDG systems shown in Table 3-2 (page 2) and the applicable components of the Adapter
5、 Kits in Table 3-1. The test stand shall have its own oil coolers(s) and shall be capable of maintaining the CSD/IDG oil temperature required without the aid of the existing MC-2 or other auxiliary oil coolers. The auxiliary oil coolers in the MC-2 adapter kits shall not be used, nor required. Benef
6、icial comments (recommendations, additions, deletions, clarifications, etc.) and any Data that may improve this document should be addressed to: WR-ALC/TILCC, 420 Second Street , suite 100, Robins AFB, GA 31098-1640. AMSC N/A FSC 4920 Provided by IHSNot for ResaleNo reproduction or networking permit
7、ted without license from IHS-,-,-A-A-59620 TABLE 3-1 ADAPTER KITS Application Model No. Part No. NSN B-52, KC- 135B, EC/RC- FSAK-3008 688307A 4920-01-147-0432C-135 FSAK-3330 65997 4920-00-532-2713C-135B FSAK-3327 693581/A 4920-00-512-3432F-4C FSAK-3333 697466 4920-00-795-9698F-4C FSAK-3341 701484 49
8、20-00-929-6805F-15 FSAK-3351 712667 4920-00-171-6621F-106A/B FSAK-3354 713711 4920-00-369-5443E-3A/RC-135M/W FSAK-3359 715734A 4920-01-013-1998F-111A/B None 12A3411-3 4920-00-794-7601C-141 None A4794 4920-00-912-0833F-16 FSAK-3360 718301 4920-01-024-5099T-38 / F-5 None 9520-0007 4920-01-486-13132 Pr
9、ovided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59620 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59620 2.3 NDI Commercial Item. The test stand shall be an already developed, state-of-the-
10、art, market proven, commercial test stand with a proven reliability track record. Minor modifications are allowed to the existing test stand. Modifications such as rearrangement or mounting of units on skids frame and changes to interface the unique military MC-2 adapters for IDG and CSD units are c
11、onsidered acceptable “NDI” modifications. 2.3.1 Major Modules of Assemblies. If the proposed TS is assembled using commercial NDI major modules or assemblies, which have not been previously merged and sold commercially as a test stand, the major modules or assembly that is proposed used shall have a
12、 proven reliability track record of reliable and satisfactory service in similar test stands. Offeror shall provide evidence that these are proven and reliable commercially available assemblies. 2.3.2 Ambient Temperature Ranges: Test Stand during Operation: 0F to +125 F Load Bank Operation (outdoor
13、environment): -25 F. to +130 F Storage, All Units: -65 F. to +160 F 2.4 Description. The proposed test stand shall be a commercial NDI test stand. It shall be compactly packaged/arranged and suitable for testing all the identified CSDs and IDGs. The test stand shall not require any modification of t
14、he “real property” (test cell floor space area, walls, ceiling, or utility/power support systems) used with the current MC-2 Test Stands. 2.4.1 DIGITAL ENTRY DEVICES. All inputs and control setting shall use digital keypads or digital keyboard entry devices. The entry keypad(s) and/or keyboard(s) sh
15、all be rugged environmentally sealed devices for use in wet, dirty or extreme environments. Toggle or selector switches are allowed for selecting the desired load on the load bank; however, the total selected load(s) must be indicated on electronic digital display(s). 2.4.2 ELECTRONIC DIGITAL DISPLA
16、YS. Except for protective alarms, all indicators shall be electronic shall be electronic digital displays. Electronic digital displays shall be LED, LCD vacuum fluorescent or electro-fluorescent type devices. Mechanical counters, odometers or turn counter devices are not acceptable “electronic digit
17、al displays”. 2.4.3 DATA INPUT AND OUTPUT CONSISTENT FORMATS. Display formats should be consistent within a system. When appropriate for users, the same format should be used for input and output. Data entry formats should match the source document formats. 2.4.4 LABELING APPLICATION. Labeling shall
18、 be of a consistent type and consistently located within the entire system. Labels, legends, placards, signs, markings, or a combination of these shall be provided whenever personnel must identify items (except when it is obvious to the observer what an item is). 2.4.5 MAJOR MODULES OF ASSEMBLIES. W
19、hile the final configuration is dependent on the commercial NDI test stand proposed, some of the major modules or assemblies should consist of: 4 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59620 Control Console Drive Unit/Prime Mover Drive C
20、ontrol Panel Drive Power Supply Gearbox Gearbox Output pad Hydraulic Supply Hydraulic Instrumentation Panel Oil Cooler Oil Heater Interface Panel Load Bank Control Panel Load Bank Air Cooling Blower Electrical Hoist Skid (Mounting) Frame Mounting Pad for CSD Adapters Blast Air Blower Work Bench Buil
21、t in Digital Multi-Meter Instrumentation as Required 2.4.6 Mounting Pad for CSD Adapters. A single mounting pad shall be provided for permitting compatibility with the mechanical adapters currently used with the current MC-2 test stands. 2.4.7 Interface Panel. An interface panel shall be provided as
22、 the electrical connection points for the generator under the test and CSD adapter and associated generator control units/voltage regulators. The connecting points, connectors, test leads, indicators, in the interface panel shall be compatible with all the existing MC-2 adapters. 2.4.8 Drive Unit. T
23、he drive unit shall consist of a 125 to 150Hp DC drive motor. The controller shall a state-of-the-art microprocessor based DC power supply, with electronic digital inputs and outputs. The power supply shall contain built-in self test capabilities and shall have protection against drive unit over spe
24、ed for safe operation of the drive unit and the unit under test (UUT) 2.4.9 Load Bank. The load bank shall be a 75 to 90KW, 400 Hz (PF 1.0) resistive load bank. To allow for outdoor heat dissipation, the load bank shall be in a rain tight and splash proof enclosure. The incremental loading steps sha
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AIRFORCEAA596202004TESTSTANDAIRCRAFTGENERATORCONSTANTSPEEDDRIVECSDUNITS 航空器 发电机 等速 驱动器 试验 PDF

链接地址:http://www.mydoc123.com/p-427131.html