1、A-A-50681 V9 779777LI 002397b 2 M c-3Y- 3 3 pEmm-1 30 Mav 1989 COMMERCIAL ZTEM DESCRIPTION TRAILER, MAINTENANCE POWER The General Services Administration has authorized the use of this Commercial Item Description. Scope. to supply electric power, ventilation, compressed air, and water removal for te
2、lecommunication and utility installation and maintenance crews in cable vaults and manhours at locations distant from commercial sources of power. Applicable documents. This commercial item description (CID) covers a mobile power unit used Specifications and standards. The following specifications a
3、nd standards form part of this CID to the extent specified herein. the issues of this document are those listed in the issue of the Department of Defense Index of Specifications and Standards (DODISS) and supplement thereto, cited in the solicitation. Unless otherwise specified, SPECIFICATIONS MILIT
4、ARY VV G 1690 Gasoline, automotive, leaded or unleaded MIL G 3056 Gasoline, automotive, combat MS 5 13 3 6 Lunette and coupler drawbar, ring (Copies of specifications, standards and other Government documents required by contractors in connection with specific acquisition functions should be obtaine
5、d from the contracting activity or as directed by the contracting activity). Order of precedence. and the references cited herein (except for the associated detail specifica- tions, specification sheets or MS standards) the text of this CID takes prece- dence. Nothing in this CID, however, supersede
6、s applicable laws and regulations unless a specific exemption has been obtained. In the event of conflict between the text of this CID Beneficial comments, recommendations, additons, deletions, clarification, etc. and any data which may improve this document should be sent to: Division SA-ALC/MMEDO,
7、 Kelly AFB TX 78241-5000 Engineering AMSC NIA FSC 4940 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. THIS DOCUMENT CONTAINS PAGES. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-50681 q9 7799974 0023777 4 e A-
8、A-50 6 8 1 Salient characteristics. 1. General. The mobile power utility trailer shall be suitable for its intended use. strength. Individual components shall be durable, reliable and suited for their intended purposes. standard commercial products. all components. shall have the following approxima
9、te minimum/maximum dimensions: Structural elements shall be rigid and possess the requisite The engine generator set, compressors and pump shall be Service and parts shall be readily available for The unit shall be towable at 60 MPH along paved highways. It Length 124 in 1 136 in Width 68 in / 68 in
10、 Height 50 in / 58 in 2. Trailer. The trailer shall be a low profile unit, properly balanced to be handled by one person. The frame shall be all steel construction with minimum 10 gauge formed channel steel capable of supporting all equipment and accessories. The trailer shall have a spring steel su
11、spension. It shall travel on two F78x15, minimum size, tires, and have a 36 inch adjustable front landing gear with pneumatic tire. hydraulic, fully self-contained, surge type service brakes. A towbar with lunette conforming to MS51336 (3 inch dia. eye and 1 5/8 dia. ring) and safety chains shall be
12、 provided. The trailer shall have fenders, recessed tail lights, stop and turn signals. A seven conductor electrical connector shall comply with SAE 5560. shall be provided. It shall have mechanical type parking brakes and An intervehicle jumper cable with plugs conforming to SAE 5560 3. Equipment a
13、nd storage area. provided. Winged doors on each side of th storage cabinet shall be securable in Equipment and accessory storage areas shall be the open position; The storage cabinet shall have a minimum of 20 cubic feet designated storage space with access from either side. The equipment area shall
14、 be sufficient to provide for ease of access for full servicing of all equipment and the rear of the control panel. There shall also be storage areas for hoses, platform supports, and extension boards. The floor shall have a sufficient number of drain holes. The storage compartment shall have a DC l
15、ight. All doors shall be lockable with a common key. 4. Control panel. the control panel shall be easily accessible and located at the rear of the unit. It shall be incorporated in the shell of the equipment storage cabinet. It shall have a DC light. It shall have a door to covers all switches, outl
16、ets, gauges and meters. It shall be lockable with the common key. It shall include three 120 VAC, GFI protected duplex receptacles; one 240 VAC, GFI protected receptacle; one DC ammeter, two AC ammeteres, one AC voltmeter, and electric hour meter, and circuit breaker on/off switched for each circuit
17、. The rear of the control panel shall provide for easy removal and re-connenction of individual components. 5. Engine generator set. A minimum 7.5 KW, continuous duty, 120/240 VAC, 60 cycle, simgle phase, AC/DC generator directly connected to a four cycle gaso- line engine rated 14 HP at 1800 RPM, w
18、ater cooled, oil lubricated, electrically started, and designed in accordance with NEMA, AIEE and ASA standards shall be 2 ry O a a Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-SOhL 47 W 9777774 0023778 b A-A- 5 O 6 8 1 provided. shall have a
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
2000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AIRFORCEAA506811989TRAILERMAINTENANCEPOWER 维修 电力 拖车 PDF

链接地址:http://www.mydoc123.com/p-426846.html