1、ANSI/AHRI Standard 870 (formerly ARI Standard 870)2005 Standard for Performance Rating of Direct GeoExchange Heat Pumps AHRI STANDARD 870-2005 (formerly ARI Standard 870-2005) WITH ADDENDUM 1, Performance Rating of Direct GeoExchange Heat Pumps June 2009 AHRI Standard 870-2005 with Addendum 1, Perfo
2、rmance Rating of Direct GeoExchange Heat Pumps, is comprised of only the shaded portions shown. The June 2009 Addendum 1 has beenincorporated into the already published 2005 version of AHRI Standard 870 to avoid confusion.Particular additions (shown shaded in the standard), deletions (shown with a s
3、trikethrough and shaded in the standard), and corrections (shown shaded in the standard) are as follows: 1 In Appendix C, equation C2 was corrected. System Capacity = qhx (3.412) (Wc+ Wah) = qcoolingAir-Conditioning, Heating, and Refrigeration Institute 2111 Wilson Blvd, Suite 500 Arlington, VA 2220
4、1 Price $10.00 (M) $20.00 (NM) Copyright 2005, by Air-Conditioning, Heating, and Refrigeration Institute Printed in U.S.A. Registered United States Patent and Trademark Office IMPORTANT SAFETY DISCLAIMER ARI does not set safety standards and does not certify or guarantee the safety of any products,
5、components or systems designed, tested, rated, installed or operated in accordance with this standard/guideline. It is strongly recommended that products be designed, constructed, assembled, installed and operated in accordance with nationally recognized safety standards and code requirements approp
6、riate for products covered by this standard/guideline. ARI uses its best efforts to develop standards/guidelines employing state-of-the-art and accepted industry practices. ARI does not certify or guarantee that any tests conducted under its standards/guidelines will be non-hazardous or free from ri
7、sk. ARI CERTIFICATION PROGRAM PROVISIONS Scope of the Certification Program The certification program includes all factory made residential, commercial and industrial Direct Geoexchange Heat Pumps as defined in Section 3. It does not apply to the rating and testing of retrofit units. Certified Ratin
8、gs The following certification program ratings are verified by test at the Standard Rating Conditions: 1. Cooling Capacity, Btu/h 2. Energy Efficiency Ratio, EER, Btu/Wh 3. Heating Capacity, Btu/h 4. Coefficient of Performance, COP Note: This standard supersedes ARI Standard 870-2001. TABLE OF CONTE
9、NTS SECTION PAGE Section 1. Purpose 1 Section 2. Scope .1 Section 3. Definitions .1 Section 4. Classification .3 Section 5. Test and Rating Requirements .3 Section 6. Minimum Data Requirements for Published Ratings 6 Section 7. Operating Requirements 6 Section 8. Marking and Nameplate Data 8 Section
10、 9. Conformance Conditions .8 Check page numbers TABLES Table 1. Classification of Direct Geoexchange Heat Pumps .3 Table 2. Minimum External Resistance 5 APPENDICES Appendix A. References - Normative .9 Appendix B. References - Informative .9 Appendix C. Outdoor Water Coil Method of Testing Direct
11、Geoexchange Heat Pumps for Capacity - Informative .10 FIGURES FOR APPENDICES Figure C1. Outdoor Water Coil Test Set-Up for Direct Geoexchange Heat Pumps .10 _ ANSI/AHRI STANDARD 870-2005 1PERFORMANCE RATING OF DIRECT GEOEXCHANGE HEAT PUMPS SECTION 1. PURPOSE 1.1 Purpose. The purpose of this standard
12、 is to establish for Direct Geoexchange Heat Pumps: definitions; classification; test and rating requirements; minimum data requirements for Published Ratings; operating requirements; marking and nameplate data; and conformance conditions. 1.1.1 Intent. This standard is intended for the guidance of
13、the industry, including manufacturers, engineers, installers, contractors and users. 1.1.2 Review and Amendment. This standard is subject to review and amendment as technology advances. SECTION 2. SCOPE 2.1 Scope. This standard applies to factory made residential, commercial and industrial Direct Ge
14、oexchange Heat Pumps, as defined in Section 3. 2.1.1 Energy Source. This standard applies only to electrically-driven, mechanical compression type systems. 2.1.2 Alternative Applications. Equipment designed for rating under this standard may not be suitable for alternative applications covered in IS
15、O 13256-1. 2.2 Exclusions. This standard applies to the rating and testing of complete refrigeration systems and does not apply to individual assemblies for separate use. SECTION 3. DEFINITIONS All terms in this document shall follow the standard industry definitions in the current edition of ASHRAE
16、 Terminology of Heating, Ventilation, Air Conditioning and Refrigeration unless otherwise defined in this section. 3.1 Coefficient of Performance (COP). A ratio of the Cooling/Heating Capacity in watts W to the power input values in watts W at any given set of Rating Conditions expressed in watts/wa
17、tt W/W. For heating COP, supplementary resistance heat shall be excluded. 3.1.1 Standard Coefficient of Performance. A ratio of the capacity to power input value obtained at Standard Rating Conditions. 3.2 Cooling Capacity. The capacity associated with the change in air enthalpy which includes both
18、the Latent and Sensible Capacities expressed in Btu/h W. 3.2.1 Latent Capacity. Capacity associated with a change in humidity ratio. 3.2.2 Sensible Capacity. Capacity associated with a change in dry-bulb temperature. 3.3 Direct Geoexchange Heat Exchanger. A continuous sealed underground closed loop
19、heat exchanger with one refrigerant supply tube and one refrigerant return tube. More than one such Direct Geoexchange Heat Exchanger may be supplied with each heat pump and the Direct Geoexchange Heat Exchanger(s) may be factory or field assembled. ANSI/AHRI STANDARD 870-2005_ 2 3.4 Direct Geoexcha
20、nge Heat Pump. A heat pump consisting of one or more factory made assemblies which normally include an indoor conditioning coil with air moving means, compressor(s) and refrigerant-to-earth heat exchanger(s), including means to provide a heating function or a cooling function or both. The separate a
21、ssemblies shall be designed to be used together, and the requirements of rating outlined in the standard are based upon the use of matched assemblies. 3.4.1 Functions. Direct Geoexchange Heat Pumps shall provide the function of air-circulating, cooling and heating with controlled temperature, and ma
22、y include the functions of water heating, air-cleaning, dehumidifying or humidifying. Models designated as “cooling only“ units need not include the heating function, and models designated as “heating only“ units need not include the cooling function. 3.5 Energy Efficiency Ratio (EER). A ratio of th
23、e Cooling Capacity in Btu/h to the power input values in watts at any given set of Rating Conditions expressed in Btu/(Wh). 3.5.1 Standard Energy Efficiency Ratio. A ratio of the capacity to power input value obtained at Standard Rating Conditions. 3.6 Heating Capacity. The capacity associated with
24、the change in dry-bulb temperature expressed in Btu/h W. 3.7 Part-Load Rating. A rating based on tests performed at Part-Load Rating Conditions. 3.8 Published Rating. A statement of the assigned values of those performance characteristics, under stated Rating Conditions, by which a unit may be chose
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AHRI8702005PERFORMANCERATINGOFDIRECTGEOEXCHANGEHEATPUMPSPDF

链接地址:http://www.mydoc123.com/p-422594.html