AHRI 870 I-P-2016 Performance Rating of Direct Geoexchange Heat Pumps.pdf
《AHRI 870 I-P-2016 Performance Rating of Direct Geoexchange Heat Pumps.pdf》由会员分享,可在线阅读,更多相关《AHRI 870 I-P-2016 Performance Rating of Direct Geoexchange Heat Pumps.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、 2016 Standard for Performance Rating of Direct Geoexchange Heat Pumps AHRI Standard 870 (I-P) - 2016 Price $10.00 (M) $20.00 (NM) Copyright 2016, by Air-Conditioning, Heating, and Refrigeration Institute Printed in U.S.A. Registered United States Patent and Trademark Office IMPORTANT SAFETY DISCLAI
2、MER AHRI does not set safety standards and does not certify or guarantee the safety of any products, components or systems designed, tested, rated, installed or operated in accordance with this standard/guideline. It is strongly recommended that products be designed, constructed, assembled, installe
3、d and operated in accordance with nationally recognized safety standards and code requirements appropriate for products covered by this standard/guideline. AHRI uses its best efforts to develop standards/guidelines employing state-of-the-art and accepted industry practices. AHRI does not certify or
4、guarantee that any tests conducted under its standards/guidelines will be non-hazardous or free from risk. Note: This standard supersedes ANSI/AHRI Standard 870-2005 with Addendum 1. For SI ratings, see AHRI Standard 871 (SI) -2016. AHRI CERTIFICATION PROGRAM PROVISIONS Scope of the Certification Pr
5、ogram The certification program includes all factory made residential, commercial and industrial Direct Geoexchange Heat Pumps as defined in Section 3. It does not apply to the rating and testing of retrofit units. Certified Ratings The following ratings are verified by test at the Standard Rating C
6、onditions: 1. Full load Cooling Capacity, Btu/h 2. Full load Heating Capacity, Btu/h 3. Energy Efficiency Ratio, EER, Btu/(Wh) 4. Coefficient of Performance, COP (W/W) 5. Part-load Cooling Capacity (if applicable), Btu/h 6. Part-load Heating Capacity (if applicable), Btu/h 7. Part-load Energy Effici
7、ency Ratio (if applicable), EER, Btu/(Wh) 8. Part-load Coefficient of Performance (if applicable), COP (W/W) TABLE OF CONTENTS SECTION PAGE Section 1. Purpose 1 Section 2. Scope . 1 Section 3. Definitions . 1 Section 4. Classification . 3 Section 5. Test Requirements . 4 Section 6 Rating Requirement
8、s . 4 Section 7. Minimum Data Requirements for Published Ratings 5 Section 8. Operating Requirements 6 Section 9. Marking and Nameplate Data . 6 Section 10. Conformance Conditions. 6 TABLES Table 1. Classification of Direct Geoexchange Heat Pumps . 3 Table 2. Capacity Rating Multiples . 4 Table 3. S
9、tandard Rating Conditions 5 APPENDICES Appendix A. References Normative 7 Appendix B. References Informative 7 AHRI STANDARD 870 (I-P)-2016 1 PERFORMANCE RATING OF DIRECT GEOEXCHANGE HEAT PUMPS Section 1. Purpose 1.1 Purpose. The purpose of this standard is to establish for Direct Geoexchange Heat P
10、umps: definitions; classification; test and rating requirements; minimum data requirements for Published Ratings; operating requirements; marking and nameplate data; and conformance conditions. For the remainder of this standard, the terms “heat pump” or “equipment” are also used to designate Direct
11、 Geoexchange Heat Pumps. 1.1.1 Intent. This standard is intended for the guidance of the industry, including manufacturers, engineers, installers, contractors and users. 1.1.2 Review and Amendment. This standard is subject to review and amendment as technology advances. Section 2. Scope 2.1 Scope. T
12、his standard applies to factory made residential, commercial and industrial Direct Geoexchange Heat Pumps as defined in Section 3, and within the capacity range of 18,000 Btu/h through 180,000 Btu/h. 2.1.1 Energy Source. This standard applies only to electrically-driven, mechanical vapor-compression
13、 refrigeration systems. 2.1.2 Alternative Applications. Equipment designed for rating under this standard is not suitable for alternative applications covered in ANSI/AHRI/ASHRAE ISO Standards 13256-1 and 13256-2. 2.1.3 Exclusions. This standard applies to the rating and testing of complete refriger
14、ation systems and does not apply to individual system components for separate use. Section 3. Definitions All terms in this document will follow the standard industry definitions in the ASHRAE Terminology website (https:/www.ashrae.org/resources-publications/free-resources/ashrae-terminology) unless
15、 otherwise defined in this section. 3.1 Coefficient of Performance (COP). The ratio of Cooling/Heating Capacity in watts to the power input values in watts at any given set of Rating Conditions expressed in watts/watt. For heating COP, supplementary resistance heat shall be excluded.3.2 Cooling Capa
16、city. The capacity associated with the change in air enthalpy which includes both the latent and sensible capacities expressed in Btu/h. 3.3 Direct Geoexchange Heat Exchanger. A continuous sealed tube(s) heat exchanger with refrigerant supply and refrigerant return. This may be comprised of several
17、tubes and may be supplied with each heat pump. The heat exchanger(s) may be factory or field assembled. 3.4 Direct Geoexchange Heat Pump (DGX). A heat pump consisting of (1) one or more factory made assemblies which normally include an indoor conditioning coil with air or water moving means, (2) com
18、pressor(s), and (3) a subsurface refrigerant piping loop system functioning as a Direct Geoexchange Heat Exchanger, and may include means to provide a heating function, or a cooling function, or both. The separate system components shall be designed for use together. Models designated as “cooling on
19、ly” need not include the heating function and models designated “heating only” need not include the cooling function. The four types of Direct Geoexchange Heat Pumps within the scope of this standard are as follows. 3.4.1 DGX-to-Air Split System (Type 1). Compressor and indoor coil are in separate c
20、abinets. Indoor coil is with or without a fan. AHRI STANDARD 870 (I-P)-2016 2 3.4.2 DGX-to-Air Packaged System (Type 2). Compressor and indoor coil are in one cabinet, with or without a fan. 3.4.3 DGX-to-Water Split System (Type 3). Compressor and Indoor water-to-refrigerant heat exchanger are in se
21、parate cabinets. Indoor water-to-refrigerant heat exchanger is with or without a pump. 3.4.4 DGX-to-Water Packaged System (Type 4). Compressor and indoor water-to-refrigerant heat exchanger are in one cabinet. Indoor heat exchanger is with or without a pump. Note: ANSI/ASHRAE Standard 194 uses the t
22、erm Direct-expansion Ground Source Heat Pump in lieu of Direct Geoexchange Heat Pump. 3.5 Effective Power Input. The average electrical power input in watts, supplied to the equipment within a defined interval of time. This is the sum of the following, as appropriate: 3.5.1 The power input for the o
23、peration of the compressor, excluding supplemental electric heat, W 3.5.2 The power input of all control and safety devices of the equipment, W 3.5.3 The proportional power input of the conveying devices for the transport of heat transfer media through the heat pump only (e.g., fans, pumps, whether
24、internal or external, whether provided with heat pump or not), W 3.6 Energy Efficiency Ratio (EER). The ratio of the Cooling Capacity in Btu/h, to the Effective Power Input in watts, at any given set of Rating Conditions, Btu/(Wh). 3.7 Heating Capacity. For DGX-to-Air systems, the rate at which the
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AHRI870IP2016PERFORMANCERATINGOFDIRECTGEOEXCHANGEHEATPUMPSPDF

链接地址:http://www.mydoc123.com/p-422593.html