AHRI 261 SI-2012 Sound Rating of Ducted Air Moving and Conditioning Equipment.pdf
《AHRI 261 SI-2012 Sound Rating of Ducted Air Moving and Conditioning Equipment.pdf》由会员分享,可在线阅读,更多相关《AHRI 261 SI-2012 Sound Rating of Ducted Air Moving and Conditioning Equipment.pdf(37页珍藏版)》请在麦多课文档分享上搜索。
1、 i 2012 Standard for Sound Rating of Ducted Air Moving and Conditioning Equipment Approved by ANSI on June 26, 2013 ANSI/AHRI Standard 261 (SI) Price $15.00 (M) $30.00 (NM) Copyright 2012, by Air-Conditioning, Heating and Refrigeration Institute Printed in U.S.A. Registered United States Patent and
2、Trademark Office IMPORTANT SAFETY DISCLAIMER AHRI does not set safety standards and does not certify or guarantee the safety of any products, components or systems designed, tested, rated, installed or operated in accordance with this standard/guideline. It is strongly recommended that products be d
3、esigned, constructed, assembled, installed and operated in accordance with nationally recognized safety standards and code requirements appropriate for products covered by this standard/guideline. AHRI uses its best efforts to develop standards/guidelines employing state-of-the-art and accepted indu
4、stry practices. AHRI does not certify or guarantee that any tests conducted under its standards/guidelines will be non-hazardous or free from risk. Note: This standard supersedes AHRI Standard 260-2001 and differs in the following ways. Data in the 63 Hertz Octave Band is required; Sound power shall
5、 be determined following AHRI Standard 220 procedures if a reverberation room is used; Sound power shall be determined following ISO 9614 procedures if Sound Intensity is used; The Duct End Correction shall be determined following ASHRAE Technical Report 1314; Acoustic Test Elbow corrections shall f
6、ollow the method described by Beranek (1960). TABLE OF CONTENTS SECTION PAGE Section 1. Purpose . .1 Section 2. Scope .4 Section 3. Definitions. 4 Section 4. Requirements for Acquiring Sound Data. . 7 Section 5. Sound Level Calculations 15 Section 6. Equipment Sound Ratings. 17 Section 7. Conformanc
7、e Conditions 20 TABLES Table 1. Reproducibility in the Determination of Ducted Equipment Sound Power Levels . 14 FIGURES Figure 1. Typical Ducted Product Application 2 Figure 2. Relationship Between Sound Components and Sound Sources .3 Figure 3. Concept Reverberation Room Ducted Discharge Test Set-
8、up 9 Figure 4. Concept Sound Intensity Ducted Discharge Test Set-up. .9 Figure 5. Concept Reverberation Room Ducted Inlet Test Set-up. 9 Figure 6. Concept Sound Intensity Ducted Inlet Test Set-up. 10 Figure 7. Concept Reverberation Room Casing Radiated Test Set-up .10 Figure 8. Concept Sound Intensi
9、ty Casing Radiated Test Set-up .10 Figure 9. Concept Reverberation Room Free Discharge (or Inlet) Combined with Casing Radiated Test Set-up 11 Figure 10.Concept Sound Intensity Free Discharge (or Inlet) Combined with Casing Radiated Test Set-up 11 Figure 11. Concept Reverberation Room Free Discharge
10、 (or Inlet) Set-up .12 Figure 12. Concept Sound Intensity Free Discharge (or Inlet) Test Set-up12 APPENDICES Appendix A. References Normative .21 Appendix B. References - Informative 22 Appendix C. Acoustic Test Elbow Correction (E2) - Normative 23 Appendix D. Effects of Other Sources - Normative 25
11、 Appendix E. Supply Fan Modulation Device Effects - Normative .27 Appendix F. Determination of Sound Power Using Sound Intensity - Normative. 28 TABLES FOR APPENDICES Table C.1 Insertion Loss of Unlined Elbows.23 Table C.2 Examples of Test Elbow Insertion Loss, dB .24 Table F.1 Performance Verificat
12、ion Limits .30 Table F.2 Convergence Index 31 FIGURES FOR APPENDICES Figure C.1 Insertion Loss of Unlined Acoustic Test Duct Elbows. 23 Figure F.1 Performance Verification by Comparison with a Reference Sound Source Set-up. 30 ANSI/AHRI STANDARD 261 (SI)-2012_ 1 SOUND RATING OF DUCTED AIR MOVING AND
13、 CONDITIONING EQUIPMENT Section 1. Purpose 1.1 Purpose. The purpose of this standard is to establish a method of sound rating the indoor portions of ducted air moving and conditioning equipment. The standard provides definitions; requirements for acquiring mapped sound data; sound power level calcul
14、ations and ratings; minimum data requirements for published sound ratings; and conformance conditions. 1.1.1 Intent. This standard is intended for the guidance of the industry, including manufacturers, engineers, installers, contractors and users. 1.1.2 Review and Amendment. This standard is subject
15、 to review and amendment as technology advances. 1.2 Rationale. Ducted Equipment presents unique challenges when providing sound ratings since their ratings are used to both compare products and to provide the information necessary to predict application sound levels. For these reasons, the sound ra
16、tings shall define the sound coming from various portions of the equipment (Sound Components). The Sound Components are the Sound Sources that impact the application sound paths. Ducted air-conditioning equipment can have ducted discharge, ducted inlet, and casing radiated Sound Components. Dependin
17、g on its applied configuration, free discharge (or free inlet) combined with the casing radiated sound component may also be needed. All Sound Components are acoustically described/rated by utilizing a mapped sound rating approach that is typically referenced to the products supply fan operating map
18、. The supply fan is contained in the Base Unit of the product. In addition, this standard defines an approach to account for the acoustical effects of product Appurtenances (such as modulation devices or discharge/inlet plena) and other Sound Sources (such as the refrigeration circuit, return and ex
19、haust fans, etc.) to the Base Unit Mapped Sound Rating. Thus, a Mapped Sound Rating can be developed for a given product configuration and each of its various Sound Components defining the sound for any product operating condition. Figure 1 presents an example of a typical product application showin
20、g the relationship between the product Sound Components and the various application sound paths. Figure 2 presents an example of a typical vertically ducted product depicting the contribution of the various product Sound Sources on the Sound Components. All Sound Components are tested utilizing eith
21、er a reverberation room (qualified by test) or using Sound Intensity. Reverberation room tests are conducted using the Comparison Method and a calibrated Reference Sound Source, while the Sound Intensity tests are conducted using measurements made at discrete points or by the scanning method. Sound
22、ratings are in the form of Octave Band Sound Power Levels (dB) from 63 to 8000 Hz derived from One-third Octave Band measurements. In addition to the stated Octave Band ratings, this standard can be used to provide One-third Octave Band sound ratings from 50 to 10,000 Hz. _ANSI/AHRI STANDARD 261 (SI
23、)-2012 2 In the example presented in Figure 1, there are two Sound Components present, ducted discharge and free inlet combined with casing radiated. The ducted discharge sound component affects or defines the source strength for two application sound paths 1) the supply duct airborne sound and 2) t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AHRI261SI2012SOUNDRATINGOFDUCTEDAIRMOVINGANDCONDITIONINGEQUIPMENTPDF

链接地址:http://www.mydoc123.com/p-422513.html