1、 2013 Standard for Performance Rating of Commercial Heat Pump Water Heaters AHRI Standard 1301 (SI) Price $10.00 (M) $20.00 (NM) Copyright 2013, by Air-Conditioning, Heating, and Refrigeration Institute Printed in U.S.A. Registered United States Patent and Trademark Office Note: This is a new standa
2、rd For I-P ratings see AHRI Standard 1300 (I-P)-2013 Forward: Commercial Heat Pump Water Heaters (CHPWH) use an electrically driven, mechanical vapor compression refrigeration system to transfer heat from a heat source (e.g. air, ground, water, brine solution) to potable water to provide service hot
3、 water. This rating method standard covers CHPWH that are not subject to the U.S. Department of Energy (DOE) efficiency regulations for residential heat pump water heaters. IMPORTANT SAFETY RECOMMENDATIONS AHRI does not set safety standards and does not certify or guarantee the safety of any product
4、s, components or systems designed, tested, rated, installed or operated in accordance with this standard/guideline. It is strongly recommended that the products be designed, constructed, assembled, installed and operated in accordance with nationally recognized safety standards and code requirements
5、 appropriate for products covered by this standard/guideline. AHRI uses its best efforts to develop standards/guidelines employing state-of-the-art and accepted industry practices. AHRI does not certify or guarantee that any tests conducted under its standards/guidelines will be non-hazardous or fre
6、e from risk. TABLE OF CONTENTS SECTION PAGE Section 1. Purpose 1 Section 2. Scope . 1 Section 3. Definitions. 1 Section 4. Classifications . 3 Section 5. Test Requirements 3 Section 6. Rating Requirements . 3 Section 7. Minimum Data Requirements for Published Ratings . 5 Section 8. Marking and Namep
7、late Data . 6 Section 9. Conformance Conditions 7 TABLES Table 1. Classification of Commercial Heat Pump Water Heaters (CHPWH) 3 Table 2. AS-CHPWH Standard Rating Conditions 4 Table 3. DG-CHPWH Standard Rating Conditions 4 Table 4. WS-CHPWH Standard Rating Conditions . 4 Table 5. CHPWH Hot Water Sta
8、ndard Rating Conditions . 4 APPENDICES Appendix A. References - Normative 7 Appendix B. References - Informative. 8 _AHRI STANDARD 1301 (SI)-2013 1 PERFORMANCE RATING OF COMMERCIAL HEAT PUMP WATER HEATERS Section 1. Purpose 1.1 Purpose. The purpose of this standard is to establish for Commercial Hea
9、t Pump Water Heaters (CHPWH): definitions; test requirements; classifications; rating requirements; minimum data requirements for Published Ratings; operating requirements; marking and nameplate data; and conformance conditions. 1.1.1 Intent. This standard is intended for the guidance of the industr
10、y, including manufacturers, engineers, installers, contractors and users. 1.1.2 Limits. This standard covers CHPWH with input capacities less than or equal to 50 kW, including all three phase products and single phase products not covered by the Code of Federal Regulations, 10 CFR Part 430, Appendix
11、 E to Subpart B of Part 430 - Uniform Test Method for Measuring the Energy Consumption of Water Heaters. 1.1.3 Review and Amendments. This standard is subject to review and amendment as technology advances. Section 2. Scope 2.1 Scope. This standard applies to factory assembled Commercial Heat Pump W
12、ater Heaters (CHPWH) defined as equipment to provide potable or service hot water using alternate sources of energy as air, water and ground (geothermal) by means of electrically driven, mechanical vapor compression refrigerant systems. Different type of CHPWH are defined in Section 3. 2.1.1 This st
13、andard does not apply to testing and rating of heat pumps or water heaters covered in ANSI/AHRI/ASHRAE ISO Standard 13256-1 & 2, ANSI/AHRI Standard 1160 or ANSI/AHRI Standard 870. 2.1.2 This standard does not apply to testing and rating of Air-Cooled or Water Cooled Heat Reclaim Condensers covered i
14、n ANSI/AHRI Standard 550/590 with Addenda. Section 3. Definitions All terms in this document will follow the standard industry definitions in the ASHRAE Wikipedia website (http:/wiki.ashrae.org/index.php/ASHRAEwiki), unless otherwise defined in this section. 3.1 Condenser. A refrigeration system com
15、ponent that condenses refrigerant vapor. Desuperheating and sub-cooling of refrigerant may occur as well. 3.1.1 Water-Cooled Condenser. A component that utilizes refrigerant-to-water heat transfer means causing the refrigerant to condense and water to be heated. 3.2 Coefficient of Performance. A rat
16、io of the heating capacity in kW, to the power input value in kW at any given set of rating conditions expressed in kW/kW. AHRI STANDARD 1301 (SI)-2013_ 2 3.3 Evaporator. A refrigeration system component that evaporates refrigerant liquid and extracts heat from the air, ground or a fluid. 3.4 Commer
17、cial Heat Pump Water Heater (CHPWH). A device using a vapor compression refrigeration system to transfer heat from a low temperature source to a higher temperature sink for the purpose to of heating potable or service water including all ancillary equipment as fans, blowers, pumps, storage tanks, pi
18、ping and controls. 3.4.1 Air Source Commercial Heat Pump Water Heater (AS-CHPWH). A CHPWH that utilizes indoor or outdoor air as the heat source. 3.4.2 Direct Geo Exchange Commercial Heat Pump Water Heater (DG-CHPWH). A CHPWH that utilizes the earth as the heat source. 3.4.3 Water Source Commercial
19、Heat Pump Water Heater (WS-CHPWH). A CHPWH that utilizes water or a brine solution as the heat source. 3.5 Heating Capacity. The capacity associated with the change in water temperature expressed in kW. 3.6 Outdoor Air. Ambient outdoor air that enters the AS-CHPWH. 3.7 Published Rating. A statement
20、of the assigned values of those performance characteristics, under stated Rating Conditions, by which a unit may be chosen to fit its application. These values apply to all units of like nominal size and type (identification) produced by the same manufacturer. The term Published Rating includes the
21、rating of all performance characteristics shown on the unit or published in specifications, advertising or other literature controlled by the manufacturer, at stated Rating Conditions. 3.7.1 Application Rating. A rating based on tests performed at application Rating Condition other than Standard Rat
22、ing conditions 3.7.2 Standard Rating. A rating based on tests performed at Standard Rating Conditions as listed in Tables 2, 3, 4 and at Hot Water Standard Rating Conditions as listed in Table 5. 3.8 Rating Conditions. Any set of operating condition under which a single level of performance results
23、and that causes only that level of performance to occur. 3.8.1 Standard Rating Conditions. Rating Conditions used as the basis of comparison for performance characteristics as listed in Tables 2, 3, 4 and 5. 3.9 “Shall“ or “Should“. “Shall or “Should“ shall be interpreted as follows: 3.9.1 Shall. Wh
24、ere “shall“ or “shall not“ is used for a specified provision, that provision is mandatory if compliance with the standard is claimed. 3.9.1 Should. “Should“ is used to indicate provisions that are not mandatory but are desirable as good practice. _AHRI STANDARD 1301 (SI)-2013 3 Section 4. Classifica
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AHRI1301SI2013PERFORMANCERATINGOFCOMMERCIALHEATPUMPWATERHEATERSPDF

链接地址:http://www.mydoc123.com/p-422496.html