AASHTO T 131-2015 Standard Method of Test for Time of Setting of Hydraulic Cement by Vicat Needle.pdf
《AASHTO T 131-2015 Standard Method of Test for Time of Setting of Hydraulic Cement by Vicat Needle.pdf》由会员分享,可在线阅读,更多相关《AASHTO T 131-2015 Standard Method of Test for Time of Setting of Hydraulic Cement by Vicat Needle.pdf(13页珍藏版)》请在麦多课文档分享上搜索。
1、Standard Method of Test for Time of Setting of Hydraulic Cement by Vicat Needle AASHTO Designation: T 131-15 ASTM Designation: C191-13 American Association of State Highway and Transportation Officials 444 North Capitol Street N.W., Suite 249 Washington, D.C. 20001 TS-3a T 131-1 AASHTO Standard Meth
2、od of Test for Time of Setting of Hydraulic Cement by Vicat Needle AASHTO Designation: T 131-15 ASTM Designation: C191-13 1. SCOPE 1.1. These test methods determine the time of setting of hydraulic cement by means of the Vicat needle. Two test methods are given: Method A is the Reference Test Method
3、 using the manually operated standard Vicat apparatus, while Method B permits the use of an automatic Vicat machine that has, in accordance with the qualification requirements of this method, demonstrated acceptable performance. 1.2. The values stated in SI units are to be regarded as the standard.
4、The values given in parentheses are for information only. 1.3. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicabi
5、lity of regulatory limitations prior to use. WarningFresh hydraulic cementitious mixtures are caustic and may cause chemical burns to skin and tissue upon prolonged exposure. 1.4. The text of this standard references notes and footnotes that provide explanatory material. These notes and footnotes (e
6、xcluding those in tables and figures) shall not be considered as requirements of the standard. Note 1For the method for determining the time of setting by Gillmore needles, see T 154. 2. REFERENCED DOCUMENTS 2.1. AASHTO Standards: M 85, Portland Cement M 201, Mixing Rooms, Moist Cabinets, Moist Room
7、s, and Water Storage Tanks Used in the Testing of Hydraulic Cements and Concretes M 240M/M 240, Blended Hydraulic Cement T 129, Amount of Water Required for Normal Consistency of Hydraulic Cement Paste T 154, Time of Setting of Hydraulic Cement Paste by Gillmore Needles T 162, Mechanical Mixing of H
8、ydraulic Cement Pastes and Mortars of Plastic Consistency 2016 by the American Association of State Highway and Transportation Officials.All rights reserved. Duplication is a violation of applicable law.TS-3a T 131-2 AASHTO 2.2. ASTM Standards: C151/C151M, Standard Test Method for Autoclave Expansio
9、n of Hydraulic Cement C183, Standard Practice for Sampling and the Amount of Testing of Hydraulic Cement C219, Standard Terminology Relating to Hydraulic Cement C1005, Standard Specification for Reference Masses and Devices for Determining Mass and Volume for Use in the Physical Testing of Hydraulic
10、 Cements C1157/C1157M, Standard Performance Specification for Hydraulic Cement D1193, Standard Specification for Reagent Water 3. TERMINOLOGY 3.1. DefinitionsThe terms used in this test method are defined in accordance with ASTM C219. 4. SUMMARY OF TEST METHOD 4.1. A paste that is proportioned and m
11、ixed to normal consistency, as described in the test method T 129, is molded and placed in a moist cabinet and allowed to start setting. Periodic penetration tests are performed on this paste by allowing a 1-mm Vicat needle to settle into this paste. The Vicat initial time of setting is calculated a
12、s the time elapsed between the initial contact of cement and water and the time when the penetration is at 25 mm. The Vicat final time of setting is calculated as the time when the needle does not sink visibly into the paste. 5. SIGNIFICANCE AND USE 5.1. This test method provides a means of determin
13、ing compliance with a specification limit for Vicat time of setting. Refer to the appropriate specification for the cement to determine if this test method is used for specification compliance. 5.2. The measured time of setting is affected by the percentage and temperature of the water used, amount
14、of kneading the paste received, and temperature and humidity of the mixing room air and the moist cabinet or moist room air. 5.3. The measured time of setting of hydraulic cement is test method specific. Time of setting as measured by this method will not necessarily be similar to other methods used
15、 for determining the time of setting of hydraulic cements. 6. APPARATUS 6.1. Vicat ApparatusSee Annex A, Figure A1.1. The Vicat apparatus for this test method shall have a movable rod, B, of mass 300 0.5 g. 6.1.1. The end of the rod used for measuring penetration shall have a removable needle, D, wi
16、th a diameter of 1.00 0.05 mm and length no less than 50 mm. 6.1.2. The needle end that contacts the specimen shall be flat, plane, and at right angles to the axis of the rod. 2016 by the American Association of State Highway and Transportation Officials.All rights reserved. Duplication is a violati
17、on of applicable law.TS-3a T 131-3 AASHTO 6.2. Reference Masses and Devices for Determining MassConforming to the requirements of ASTM C1005. The devices for determining mass shall be evaluated for precision and accuracy at a total load of 1 kg. 6.3. Glass Graduates200- or 250-mL capacity, and confo
18、rming to the requirements of ASTM C1005. 6.4. Plane Nonabsorptive Plate100 5 mm square of similar planeness, corrosivity, and absorptivity to that of glass (see Annex A, Figure A1.1, H). 6.5. Flat TrowelHaving a sharpened straight-edged steel blade 100 to 150 mm in length. The edges, when placed on
19、a plane surface, shall not depart from straightness by more than 1 mm. 6.6. Conical RingMade of a rigid noncorroding, nonabsorbent material that shall have a height of 40 1 mm, an inside diameter at the bottom of 70 3 mm, and an inside diameter at the top of 60 3 mm (see Annex A, Figure A1.1, G). 6.
20、7. Mixer, Bowl, and PaddleConforming to T 162. 6.8. Automatic Vicat Needle Apparatus for Method BThe apparatus shall be equipped with a Vicat needle as described in Sections 6.1.1 and 6.1.2. The total mass supported by the needle tip at the time of measurement shall be 300 0.5 g. The instrument shal
21、l be capable of automatically completing and recording penetration measurements of a test specimen at predetermined time intervals not exceeding 10 min and make each penetration test at least 5 mm away from any previous penetration and at least 10 mm away from the inner side of the mold. 6.9. Specim
22、en Mold for Method BThe cement paste is held in a conical ring with a height of 40 1 mm and a removable base plate. The test surface shall have a minimum diameter of 60 3 mm. 6.10. Inspect and document Section 6 apparatus for conformance to the requirements of this test method at least every 21/2yea
23、rs. 7. REAGENTS AND MATERIALS 7.1. Mixing WaterPotable water is satisfactory for routine tests. Use water conforming to the requirements of ASTM D1193 for Type III or Type IV grade reagent water for all referee and cooperative tests. 8. SAMPLING 8.1. When the test is required for acceptance testing,
24、 sample cement in accordance with ASTM C183. 9. CONDITIONING 9.1. Maintain the temperature of the air in the vicinity of the mixing slab, the dry cement, molds, and base plates at 23.0 3.0C. 9.2. Maintain the temperature of the mixing water at 23.0 2.0C. 9.3. The relative humidity of the mixing room
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AASHTOT1312015STANDARDMETHODOFTESTFORTIMEOFSETTINGOFHYDRAULICCEMENTBYVICATNEEDLEPDF

链接地址:http://www.mydoc123.com/p-418094.html