BS PD ISO TR 16386-2014 Impact of changes in ISO fluid power particle counting Contamination control and filter test standards《对ISO 流体动力颗粒计数变化的影响 污染控制和过滤器试验标准》.pdf
《BS PD ISO TR 16386-2014 Impact of changes in ISO fluid power particle counting Contamination control and filter test standards《对ISO 流体动力颗粒计数变化的影响 污染控制和过滤器试验标准》.pdf》由会员分享,可在线阅读,更多相关《BS PD ISO TR 16386-2014 Impact of changes in ISO fluid power particle counting Contamination control and filter test standards《对ISO 流体动力颗粒计数变化的影响 污染控制和过滤器试验标准》.pdf(22页珍藏版)》请在麦多课文档分享上搜索。
1、BSI Standards Publication Impact of changes in ISO fluid power particle counting Contamination control and filter test standards PD ISO/TR 16386:2014National foreword This Published Document is the UK implementation of ISO/TR 16386:2014. It supersedes BS ISO/TR 16386:1999 which is withdrawn. The UK
2、participation in its preparation was entrusted by Technical Committee MCE/18, Fluid power systems and components, to Panel MCE/18/-/6, Contamination control. A list of organizations represented on this committee can be obtained on request to its secretary. This publication does not purport to includ
3、e all the necessary provisions of a contract. Users are responsible for its correct application. The British Standards Institution 2014. Published by BSI Standards Limited 2014 ISBN 978 0 580 78544 3 ICS 23.100.60 Compliance with a British Standard cannot confer immunity from legal obligations. This
4、 Published Document was published under the authority of the Standards Policy and Strategy Committee on 30 November 2014. Amendments/corrigenda issued since publication Date Text affected PUBLISHED DOCUMENT PD ISO/TR 16386:2014 ISO 2014 Impact of changes in ISO fluid power particle counting Contamin
5、ation control and filter test standards Consquences des changements survenus dans les normes ISO relatives au comptage des particules Contrle de la contamination et essais de filtres TECHNICAL REPORT ISO/TR 16386 Reference number ISO/TR 16386:2014(E) Second edition 2014-11-15 PD ISO/TR 16386:2014 IS
6、O/TR 16386:2014(E)ii ISO 2014 All rights reserved COPYRIGHT PROTECTED DOCUMENT ISO 2014 All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting on th
7、e internet or an intranet, without prior written permission. Permission can be requested from either ISO at the address below or ISOs member body in the country of the requester. ISO copyright office Case postale 56 CH-1211 Geneva 20 Tel. + 41 22 749 01 11 Fax + 41 22 749 09 47 E-mail copyrightiso.o
8、rg Web www.iso.org Published in Switzerland PD ISO/TR 16386:2014 ISO/TR 16386:2014(E)Contents Page Foreword iv Introduction v 1 Scope . 1 2 Historical background 1 2.1 What is ACFTD? 1 2.2 Calibrating particle counters using ACFTD 1 2.3 The original multi-pass filter test . 2 3 New test dusts 2 4 Ne
9、w APC calibration procedure 2 5 Why changes were necessary 5 6 Impact on particle sizes and contamination measurements . 5 6.1 Redefinition of particle sizes . 5 6.2 Apparent particle concentrations . 6 6.3 Contamination code reporting 8 7 Impact on filter test results . 8 7.1 Filter retained contam
10、inant capacity 8 7.2 Filtration ratio and filter efficiency . 9 8 Conclusion 11 Bibliography .12 ISO 2014 All rights reserved iii PD ISO/TR 16386:2014 ISO/TR 16386:2014(E) Foreword ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO me
11、mber bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governme
12、ntal and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. The procedures used to develop this document and those intended for its further maintenanc
13、e are described in the ISO/IEC Directives, Part 1. In particular the different approval criteria needed for the different types of ISO documents should be noted. This document was drafted in accordance with the editorial rules of the ISO/IEC Directives, Part 2 (see www.iso.org/directives). Attention
14、 is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of any patent rights identified during the development of the document will be in the Introduction and
15、/or on the ISO list of patent declarations received (see www.iso.org/patents). Any trade name used in this document is information given for the convenience of users and does not constitute an endorsement. For an explanation on the meaning of ISO specific terms and expressions related to conformity
16、assessment, as well as information about ISOs adherence to the WTO principles in the Technical Barriers to Trade (TBT), see the following URL: Foreword Supplementary information. The committee responsible for this document is ISO/TC 131, Fluid power systems, Subcommittee SC 6, Contamination control.
17、 This second edition cancels and replaces the first edition (ISO/TR 16386:1999) which has been technically revised.iv ISO 2014 All rights reserved PD ISO/TR 16386:2014 ISO/TR 16386:2014(E) Introduction This Technical Report has been prepared as an information document to give users an understanding
18、into the background and implications of a number of new and revised contamination control standards, namely ISO 11171, ISO 11943, ISO 16889 and ISO 4406. The adoption of four revised and updated contamination control standards, ISO 11171, ISO 11943, ISO 16889, and ISO 4406:1999, has produced signifi
19、cant changes in terms of how solid contamination levels and filter performance are reported. With ISO 11171, the method of calibrating automatic particle counters (APCs) using AC Fine Test Dust (ACFTD) used since the early 1970s has been replaced by a new method traceable to the USAs National Instit
20、ute of Standards and Technology. As a result, contaminant particle sizes previously referred to as 2 m, 5 m, 10 m, and 15 m became 4 m(c), 6 m(c), 10 m(c), and 14 m(c), respectively, where (c) refers to particle sizing and counting done with an APC calibrated in accordance with ISO 11171. ISO 11943
21、is a new standard for calibrating online particle counting systems that are primarily used to evaluate filter performance. With the ISO 16889 filter multi-pass test, which replaces the original ISO 4572 method, ISO Medium Test Dust (ISO MTD) replaces ACFTD as the test dust and the new ISO 11171 trac
22、eable particle counter calibration method is used. In ISO 4406:1999, the new calibration method is used, and a new 4 m(c) size class has been added to the solid contamination code for particle counts made with an automatic particle counter. These improvements in particle counting and filter testing
23、have a significant impact on contamination control activities. However, it is important to note that there has been no change in the actual contamination levels or in the performance of filters, or their effectiveness in protecting the reliability of components. This Technical Report discusses what
24、the changes are, why they were made, how they impact contamination levels and filter ratings, and how they benefit the industry. ISO 2014 All rights reserved v PD ISO/TR 16386:2014 Impact of changes in ISO fluid power particle counting Contamination control and filter test standards 1 Scope This Tec
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSPDISOTR163862014IMPACTOFCHANGESINISOFLUIDPOWERPARTICLECOUNTINGCONTAMINATIONCONTROLANDFILTERTESTSTANDARDS

链接地址:http://www.mydoc123.com/p-398767.html